Fields
Template:
Building Department
Company Name
FLORIDA MEDICAL CLINIC
Building Department - Doc Type
Permit
Permit #
16-17654
Building Department - Name
FLORIDA MEDICAL CLINIC
Address
38135 MARKET SQUARE DR
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
26
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
I <br /> l . � .. � <br /> SpectrAlert Advance Spec�fications <br /> Generai <br /> SpectrAlert Advance horns,strobes,and horn strobes shall mount to a standard 4 x 4 x 1'/z-inch back box,4-inch octagon back box,or <br />� double-gang back box.Two-wire products shall also mount to a single-gang 2 x 4 x 17B-inch back box.A universal mounting plate shall <br /> be used for mounting ceiling and wall products.The notification appliance circuit wiring shall terminate at the universal mounting plate. <br /> Also�,SpectrAlert Advance products,when used with the Sync•Circuit""Module accessory,shall be powered from a non-coded notification <br /> appl��ance circuit output and shall operate on a nominal 12 or 24 volts.When used with the Sync•Gircuit Module,12-volt-rated notification <br /> appliance circuit outputs shall operate between 8.5 and 17.5 volts;24-volt-rated notification appliance circuit outputs shall operate between <br /> 16.5a�and 33 volts.Indoor SpectrAlert Advance products shall operate between 32 and 120 degrees Fahrenheit from a regulated DC or full- <br /> wave rectified unfiltered power supply.Strobes and horn strobes shall have field-selectable candela settings including 15,15/75,30,75,95, <br />� 110,�115,135, 150,177,and 185. <br /> Strobe <br /> The strobe shall be a System Sensor SpectrAlert Advance Model listed to UL 1971 and shall be approved for fire protective service. _ ' <br /> The strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for <br /> visible signaling appliances,flashing at 1 Hz over the strobe's entire operating voltage range.The strobe light shall consist of a xenon flash <br /> tube�and associated lens/reflector system. <br /> Hor�Strobe Combination <br /> The horn strobe shall be a System Sensor SpectrAlert Advance Model listed to UL 1971 and UL 464 and shall be approved for <br /> fire p�rotective service.The horn strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with <br />' Disabilities Act requirements for visible signaling appliances,flashing at 1 Hz over the strobe's entire operating voltage range.The strobe light <br /> shall�consist of a xenon flash tube and associated lens/reflector system.The horn shall have three audibility options and an option to switch <br /> between a temporal three pattern and a non-temporal(continuous)pattern.These options are set by a multiple position switch.On four-wire <br /> products,the strobe shall be powered independently of the sounder.The horn on horn strobe models shall operate on a coded or non-coded <br />' power supply. <br /> ' Syn�hronization Module ; <br /> The module shall be a System Sensor Sync•Circuit model MDL3 listed to UL 464 and shall be approved for fire protective service.The module <br /> shall�synchronize SpectrAlert strobes at 1 Hz and homs at temporal three.Also,while operating the strobes,the module shall silence the homs � <br /> on horn strobe models over a single pair of wires.The module shall mount to a 411/16 x 411/16 x 21/8-inch back box.The module shall also <br />' control two Style Y(class B)circuits or one Style Z(class A)circuit.The module shall synchronize multiple zones.Daisy chaining two or more <br /> sync�ronization modules together will synchronize all the zones they control.The module shall not operate on a coded power supply. <br /> Standard Operating Temperature 32°F to 120°F(0°C to 49°C) <br /> Humidity Range 10 to 93%non-condensing <br /> Strobe Fiash Rate 1 flash per second <br /> Nominal Voltage Regulated 12 DC/FWR or regulated 24 DC/FWR' <br /> Oper,ating Voltage Range2 8 to 17.5 V(12 V nominal)or 16 to 33 V(24 V nominai) � <br /> Operating Voltage Range MDL3 Sync 1411odule 8.5 to 17.5 V(12 V nominal)or 16.5 to 33 V(24 V nominal) <br /> InputTerminal Wire Gauge 12 to 18 AWG , <br /> Wall-�Ulount Dimensions(inciuding lens) 5.6"L x 4.7'"W x 2.5"D(142 mm L x 119 mm W x 64 mm D) , <br /> HornaDimensions 5.6"L x 4.7"W x 1.3"D(142 mm L x 119 mm W x 33 mm D) � <br /> Wall wMountTrim Ring Dimensions(sold as a 5 pack)(TR-HS) 5.7"L x 4.8"W x 0.35"D(145 mm L x 122 mm W x 9 mm D) � <br /> Plates• I <br /> 1.Ful�l Wave Rectified(FWR)voltage is a non-regulated,time-varyirig power source that is used on some power supply and panel outputs. <br /> � <br /> 2.P,S,PC,and SC products will operate at 12 V nominal only for 15 and 15/75 cd. <br /> i <br /> Ij I <br /> I i <br />