���� The Association of ��� <br /> Pool&Spa Professionals� <br /> ANSVAPSPACC 15a ENERGY EFFICIENCY COMPLIANCE INFORMATIOIV FOR RESIDENTIAL SWIMMING POOLS <br /> PROJECT NAME: Malden CONTRACTOR NAME Challenger Pools <br /> AND ADDRESS AND ADDRESS: <br /> 6535 Northlake Dr. 6846 N. Dale Mabry , <br /> Zepherhills,Fla. Tampa,Fla.33614 <br /> owNER:David Maiden CONTRACTOR PHONE:�8,�3`886-9,�,�9 DATE:7�28�20�6 <br /> i <br /> This information sheet was prepared by the APSP-15 Residential Swimming Pool and Spa Energy Efficiency Standard Writing Committee of the Association of Pool and Spa <br /> Professionals(APSP). It is not part of the American National Standard ANSI/APSP/ICC-15a 2011 but is included for information only.Contrectors should acquire and comply <br /> with the ANSI/APSP/ICC-15a 2011 standard which can be purchased at www.apsp.org. <br /> 1. §5.2.1:Calculated pool volume <br /> a. Gallons: 11,444 �or 1, 11,444 gallons <br /> b.Calculated Gallons: 340 (surface area)X 4•5 (average depth)X 7.48 (gal/ft^3J = 11,444 <br /> 2.§5.2.1:Calculated filtration flow rate 2• 36 gpm <br /> (Pool volume=360 or 36gpm whichever is largerJ <br /> 3.§5.5.1:Pipe sizing: <br /> a.Minimum suction pipe diameter 3a. ��5 inches <br /> (Enter the smallest pipe size from Table 1 with a 6fps flaw copacity the same ormore than item 2.J <br /> b.Minimum suction branch pipe diameter 3b. 1�5 inches <br /> (Calculate:Item 2. 36 (gpm)=eranch Pipes � (quantityJ=branch flow rate 36 (gpm). <br /> Enter the smallest pipe size from Table 1 with a 6 fps flow capacity the same or more than the calculated <br /> suction branch flow rate.) <br /> c.Minimum return pipe diameter 3c. 1•5 inches <br /> (Enter the smallest pipe size from Table 1 with a 8 fps flow capocity the some or more thon item 2.) <br /> d.Minimum return branch pipe diameter 3d. �•5 inches <br /> (Calculate:Item 2. 36 (gpm)=Branch Pipes � (quantityJ=branch flow rate 36 (gpm). <br /> Enter the smallest pipe size from Table 1 with a 8 fps flow capacity the same or more than the calculated � <br /> return branch flow rate.) <br /> 4.§5.4.1:Filter type and size: <br /> a.Filter type:(Cartridge,DE,SandJ 4a.Cartridge <br /> b.Minimum filter area 4b. 96•0 sq.ft. — <br /> (Calculote:item 2. 36 (gpmJ=filter factor 0.375 �9Pm��t�2�� <br /> Filterfactors:Cartridge=0.375, Sond=15,Diatomaceous Earth=2 <br /> 5. §5.4.2:Backwash valve: � Yes, 0 No? 5. Z inches - <br /> (When using a backwash valve,enter result of item 3c or 2 inches whichever is largerJ <br /> T,able 1 � (when used) <br /> ' Pipe Size: 1.5" 2" 2.5" 3" ,3.5•' 4" 5•, 6•• <br /> Nominal GPM @ 6 fps_ 38 63 90 138 185 238 374 540 <br /> Nominal GPM @ 8 fps 51 84 119 184 247 317 499 720 <br /> 6.Single-speed pump selection(when used): <br /> §5.1.1,53.1:Forsingle-speed pumps with a total horsepower 0.99 or less,find and enter a compliant pump from the Pool Pump <br /> Database. <br /> a.Pump model 6d.PentairSuperFloVS <br /> b.Total horsepower 6b.1.5 <br /> 7.Multi-speed pump selection(when used): <br /> §5.3.2.1:Poo/s 17,000 gallons or less,se/ect pump`from the dotabase with a Curve-A gpm flow equal to item 2 or less. <br /> §5.3.2.2:Pools 17,001 gollons or more,select pump*from the datobase with a Curve-C gpm flow equal to item 2 or less. Or <br /> *Multi-speed pumps must have one speed listed thatsatisfies this requirement. <br /> a.Pump model �a.Pentair SuperFlo VS <br /> b.Pump flow 7b. 29 gpm <br /> (§5.3.2.1,5.3.2.2:Applicable Curve A or C gpm flow listed in databoseJ <br /> 3/17/15 ANSI/APSP/ICC-15 Standard Writing Committee Form 1 of 2 <br />