Laserfiche WebLink
7 <br /> I TrueA%arm Sensors <br /> � - � •r: . <br /> Sealed against rear air flow entry TrueAlarm heat sensors are self-restoring and provide rate <br /> ` Interchatigeable mounting compensated, fixed temperature sensing, selectable with <br /> EMI/RFI shielded electronics or without rate-of-rise temperature sensing.Due to its <br /> Heat sensors: small thertnal mass,the sensor accurately and quickly <br /> Selectable rate compensated,fixed temperature measures the local temperature for analysis at the fire <br /> • sensing with or without rate-of-rise operation alarm control panel. <br /> • Ratedi spacing distance between sensors: Rate-of-rise temperature detection is selectable at the <br /> control panel for either 15°F(8.3°C)or 20°F(11.1°C) <br /> Fixed Temp. UL 8 ULC FM Spacing,Either Fixed <br />� Setting Spacing remperature settiny per minute.Fixed temperature sensing is independent of <br /> � rate-of-rise sensing and programmable to operate at <br /> 135°F� so ft x so ft z0 ft x 20 ft(6.1 m)for fixed 135°F(57.2°C) or 155°F(68°C). In a slow developing <br /> (57.2°C) (18.3 m) temperature only;RTI=Quick <br /> 50 ft x 50 ft(15.2 m)for fixed fire,the temperature may not increase rapidly enough to <br /> 155°F 40 ft x 40 ft temperature with either rate-of-rise operate the rate-of-rise feature. However, an alarm will be <br /> (6s°C) (1z.z m) selection;RTI=ultra Fast initiated when the temperature reaches its rated fixed <br /> Smoke Sensors: temperature setting. <br /> • Photoelectric technology sensing TrueAlarm heat sensors can be programmed as a utility <br /> 360°smoke entry for optimum response device to monitor for temperature extremes in the range <br /> • Built-in insect screens from 32°F to 155°F(0°C to 68°C).This feature can <br /> � provide freeze warnings or alert to HVAC system <br /> ,I problems.Refer to speciftc panels for availabiliry. <br /> � 1 • • � - - • <br /> � 4-7/8"(124 mm) <br /> TrueAlarm photoelectric sensors use a stable,pulsed <br /> infrared LED light source and a silicon photodiode II"'�LED status indicator <br /> receiver tio provide consistent and accurate low power 2-3/s" <br /> smoke sensing. Seven levels of sensitivity are available (so mm) <br /> for each individual sensor,ranging from 0.2%to 3.7%per <br /> foot of smoke obscuration. Sensitivities of 0.2%, 0.5%, <br /> and 1%are for special applications in clean areas. <br /> Standard�sensitivities are 1.5%,2.0%,2.5%,3.0%, and <br /> 3.7%.Application type and sensitivity are selected and 4098-9733 Heat Sensor with Base <br /> then mon�itored at the fire alarm control panel.* <br /> � <br /> The sens�or head design provides 360°smoke entry for WARNING: In most f res, hazardous levels of smoke <br /> optimum response to smoke from any direction.Due to its and toxic gas can build up before a heat detection <br /> photoele¢tric operation,air velocity is not normally a device would initiate an alarm. In cases where Life <br /> factor, e icept for impact on area smoke flow. Safety is a factor,the use of smoke detection is highly <br /> recommended. <br /> �� 4-7/8"(124 mm) <br /> � �'`�-LED status indicator . , . , _ <br /> 2-1/8" I <br /> (54 mm)' Sensor locations should be determined only after careful <br /> consideration of the physical layout and contents of the <br /> area to be protected.Refer to NFPA 72,the National Fire <br /> Ala�•m and Signaling Code. On smooth ceilings, smoke <br /> 4098-9714 Photoelectric Sensor with Base sensor spacing of 30 ft(9.1 m)may be used as a guide.* <br /> "For detailed application information including sensitivity <br /> ; selection, refer to Installation Instructions 574-709 <br /> � <br /> I <br /> � <br /> � 3 S4098-0019-20 1/2015 <br /> f� <br />