My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
16-17664
Zephyrhills
>
Building Department
>
Permits
>
2016
>
16-17664
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/10/2017 10:27:35 AM
Creation date
7/18/2017 7:09:40 AM
Metadata
Fields
Template:
Building Department
Company Name
FLORIDA HOSPITAL ZEPHYRHILLS
Building Department - Doc Type
Permit
Permit #
16-17664
Building Department - Name
FLORIDA HOSPITAL ZEPHYRHILLS
Address
7050 GALL BLVD
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
86
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
� <br /> � . . . . - - Duct Sensor Location Considerations: <br /> - � 1. Proper duct smoke detection location must ensure <br /> ''; /Exhaust Damper sensor oK adequate airflow within the duct housing. <br /> i� <br /> 2. Duct air velocity rating is 300 to 4000 ft/min(91 to <br /> ' Exhaust.-' � �--Return air 1220 m/min). Pressure differential between intake <br /> ' and exhaust tubes is required to be between 0.015 to <br /> �o not iocate ; 1.55 inches of water(0.381 to 3937 mm). <br /> j sensor here ; <br /> 'I 3. Ensure accessibility for test and service. <br /> Return air <br /> damper 4. Proper Locations: downstream side of filters to detect <br /> fires in the filters; in return ducts, ahead of mixing <br /> areas;upstream of air humidifier and cooling coil. <br /> 5. Other locations and orientations may be required for <br /> Fresr,air-� i -•SupplyAir proper duct smoke detection depending on duct <br /> � � � access,system design, and duct airflow testing. <br /> �I oo not iocate Filter bank Sensor OK Contact your local Simplex product supplier for <br /> � sensor here aSSlStariCe. <br /> I <br /> Locations to Avoid: <br /> Additional Information. Refer to NFPA 90A,Standard 1. Where dampers closed for comfort control would <br /> for the Installation ofAir Conditioning and Ventilating interfere with airflow. <br /> Systems;NFPA 72,the National Fire Alarn:and Signaling 2. Next to outside air inlets(unless the intent is to <br /> Code; and the NE�LIA Guide for Proper Use of Smoke monitor smoke entry from that area). <br /> Detectors in Dirct Applications,and Installation Instructions 3. In return air damper branch ducts and mixing areas <br /> 574-776.,� where airflow may be restricted. <br /> . - . <br /> General��Mechanical and Environmental <br /> Air Velocity Range(linear ft/min) 300 to 4000 ft/min (91 to 1220 m/min) <br /> Sensor Sensitivity Range 0.2%to 3.7%per foot of obscuration, selectable at host control panel <br /> UL Listed Temperature Range 32° F to 100° F(0°C to 38° C) <br /> Operating Temperature Range 32° F to 122° F(0°C to 50° C) <br /> Storage Temperature Range 0° F to 140° F(-18°C to 60°C) <br /> Humidity Range 10%to 95% RH, non-condensing <br /> Wiring Connections Terminal blocks, 18 to 12 AWG(0 82 mmZ to 3.31 mmZ) <br /> Housing Color and Material Black ABS base with clear polycarbonate cover <br /> Sampling and Exhaust Tube Material Black CPVC,custom extrusion; sampling tubes are pre-drilled <br /> Remote„IStatus/Alarm LED and Test Station with Remote Status/Alarm LED <br /> Remote Alarm LED Current 1.2 mA, no impact to 24 VDC alarm current(2098-9808 or 2098-9806) <br /> Test Station Keyswitch Current 3 3 mA, no impact to 24 VDC alarm current(2098-9806) <br /> Remote Alarm LED and Test Station Distance 250 ft(76 m)maximum <br /> Addressable Operation <br /> Data Communications IDNet or MAPNET II communications, auto-select, one address per housing; <br /> ,I provides operating power to model 4098-9755 <br /> Model 4098-9756 with Supervised Multiple Relay Control,Requires Separate Fused 24 VDC from Fire Alarm Power Supply <br /> Input�/oltage 18-32 VDC(24 VDC nominal) <br /> Standby Current 3 mA @ 24 VDC <br /> Alarrtj Current 15 mA @ 24 VDC; add 15 mA for each 4098-9843 relay <br /> For use with 4098-9843 relay only, quantity of 15 maximum,distance of 500 ft <br /> Supe��vised Remote Relay Control Output (152 m)maximum; requires 4081-9008(ref 733-894) 10 kS2, 1/2 W end-of-line <br /> ,� resistor <br /> 4098-98tl43 Relay Output Ratings,Single Form C, use with Model 4098-9756 Only <br /> Coil Current 15 mA @ 24 VDC, up to 15 maximum per relay control output <br /> Relay;Contacts 7 A at 0.35 PF @ 28 VDC& 120 VAC;250 NA @ 5 VDC <br /> Locatlion Distance 500 ft(152 m)maximum to relay coils;locate relays within 3 ft(1 m)of device <br /> ;� being controlled per NFPA 72 <br /> � <br /> TYCO,SIMPLEX,and the product names lisled in(hrs material are marks anc!/or registered marks.Unauthorrzed use is strrctly prohrbrled NFPA 72 and Narrona!Frre Alarm and <br /> Signahng Code are regislered[rademarks ojthe Na(iana!Fire Prolec(ion Associa[ion(NFPA). <br /> .T.��S i m p I Ex Tyco Fire Protection Products•Westminster,MA•01441-0001•USA S4098-0030-10 11/2014 <br /> � www.simp/ex-fire.com <br /> C120/-1 Tyco Fire Prolection Products.A!!righ[s reserved Al1 spectfications and alher infarmation shown were curren!as ofdocunten(rewsion dale and are subject to change withou(notice. <br />
The URL can be used to link to this page
Your browser does not support the video tag.