My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
16-17666
Zephyrhills
>
Building Department
>
Permits
>
2016
>
16-17666
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/18/2017 7:11:55 AM
Creation date
7/18/2017 7:11:54 AM
Metadata
Fields
Template:
Building Department
Building Department - Doc Type
Permit
Permit #
16-17666
Building Department - Name
LAKES,AMANDA R BULIN & SCOTT
Address
39024 MANOR DR LOT 13
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
4
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
, -� i <br /> o� � <br /> o� <br /> . _ . . . � �� <br /> _ <br /> � <br /> HEATING&AIR CONDITIONING I� <br /> 1512 E.GARY R� � <br /> L,4KE�AND FL 33801 <br /> ORLANDO 407-COOLING TAMPA/LAKELAND 863-940-9800 I <br /> 08/09/2016 '� <br /> State Pronertv Management � <br /> 38124 Townview Avenue Aart#204 HVAC <br /> Zephyrhills,FL 33542 <br /> • Electric split system 2 ton(R-22) <br /> • The air handler is 10 years old in poor condition;the evaporator coil is extremely clogged and dirty restricting <br /> its capacity,has begun to rust and has become too brittle for a pull and clean <br /> • The AC is 10+years old in poor condition;compressor has mechanically failed rendering the unit inoperable <br /> unless replaced,exterior fin pack is damaged impacting systems performance , <br /> • NOTE: some sheetrock may have to be opened to install the new air handler. All repairs of sheetrock to <br /> be completed by GC <br /> • Ductwork is in fair condition;all connections need to be sealed properly <br /> • Due to a compressor blow out the refrigerant line set has been clogged with non-condensable and sludge like <br /> contaminants,a line flush can be done,but to ensure optimal protection for the new equipment it is highly <br /> recommended to replace refrigerant line set <br /> • 150AMP panel <br /> Incurred service: <br /> Diagnostic fee(waived) <br /> 2 ton HVAC svstem includes the followin�: <br /> 2 ton outdoor unit 14 SEER with R-410A refrigerant <br /> 2 ton air handler with <br /> Digital Thermostat <br /> Ductwork(tie into existing) <br /> Low&high voltage(tie into existing) <br /> Filter rack/Grille <br /> Safety float switch installation <br /> Mastic seal joints at system <br /> Remove existing&discard <br /> Hurricane pad for outdoor unit <br /> ' Hurricane tie downs <br /> Includes all labor&material to complete job <br /> Mechanical permit <br /> Costs- <br /> Above system$2,750.00 <br /> Return plenum$150.00 <br /> Refrigerant lines$300.00 <br /> David Weber-OK to proceed 08.11.2016 <br /> Total: $3,200.00 <br />
The URL can be used to link to this page
Your browser does not support the video tag.