<br /> � TRINITY I ERD '
<br /> AP,PEN�U(1:.PTfACHMENT REqUIREMENTS FOR WIND UPIJFT RESISTANCE
<br /> Table peck Application Type �esalPtlon Page
<br /> lA �f✓ood New or Reroof(Tear-Of� A-2 Mech.Attached Anchbr Sheet,Bonded Insulatlon,8onded Roof Cover 5-6
<br /> 10 1/Vood New,Reroof(Tear-Off)or Recover B Mech.Attached 0ase Insulation,Bonded Top Insulatton,Bonded Roof Cover 7
<br /> SC �Vood New,Reroof(Tear-Otf)or Recover C Mech.Attached Insulation,Bonded Roof Cover � 8-9
<br /> 1D Wood New,Reroof(Tear•Off)or Recover D Prelim.Attached Insulatlon,Mech.Attached Base Sheet,Bonded Roof Cover 10-12
<br /> lE-1 Wood New,Reroo((Tear-Off) E Non-Insulated,Mech.Attached Base Sheet,Bonded Roof Cover 13-IS
<br /> IE-2 Woad New,Reroof(Tear-Off)or Recover E � Non-Insulated,Mech.Attached Base Sheet,Bonded Roof Cover 16-17
<br /> 1F , ood New or Reroof(Tear-Off) F Non-Insulated,Bonded Roof Cover 17
<br /> 2A $teel or Conc. New,Reroof(Tear-Offl or Recover B Mech.Aftached Base Insulatfon,Bonded Top Insulation,Bonded Roof Cover 18-20
<br /> 2B $teel or Conc. New,Reroof(Tear-OffJ or Recover C Mech.Attached Insulation,Bonded Roof Cover 21-25
<br /> 2C teel or Conc. New,Reroof(Tear-Off)or Recover D �Prelim.Attached InsutaUon,Mech.Attached Base Sheet,Bonded Roof Cover 26-28
<br /> 3A oncrete New or Reroof(Tear-OffJ A-1 Bonded Insulatlon,Bonded Roof Cover 29-36
<br /> 38 toncrete New or Reroof(Tear-Of� A-3 Bonded Temp Roaf/Vapor Barrler,Bonded Insulation,Bonded Roof Cover 37
<br /> 3C oncrete New or Reroof(Tear•Of� F Non-Insulated,Bonded Roof Cover 37
<br /> 4A �WIC New or Reroof(Tear-Of� A-1 Bonded Insulation,Bonded Roof Cover 3839
<br /> 46 ;IWIC New or Reroof(Tear-Offl A-2 Mech.Attached Anchor Sheet,Bonded Insulation,8onded Roof Cover 40
<br /> 4C ILWIC New,Reroo((Tear-Off) E Non-insulated,Mech.Attached Base Sheet,Bonded Roof Cover 41-44
<br /> SA �CWF New or Reroof(Tear-Off) A-1 Bonded insulation,Bonded Roof Cover 45
<br /> SB �CWF New or Reroof(Tear-Off) A-2 Mech.Attached Anchor Sheet,Bonded Insufation,Bonded Roof Cover 46
<br /> SC CWF New,Reroof(Tear-Off)or Recover C Mech.Attached Insulation,Bonded Roof Cover 46
<br /> SD CVJF New,Reroof(Tear-Offl E Non-Insulated,Mech.Attached Base Sheet,Bonded Roof Cover 47
<br /> 6A �Gypsum Reroof(Tear-Ot� A-1 Bonded Insulatlon,Boniled Roof Cover 46-49
<br /> 68 Gypsum Reroof(Tear-Off) A-2 Mech.A[tached Anchor Shee[,Bonded Insulation,Bonded Roof Cover 50 -
<br /> 6C Gypsum Reroof(fear-Offl C Mech.Attached Insulation,Bonded Roof Cover 50
<br /> 6D Gypsu'm Reroof(Tear-Of� E Non-Insulated,Mech.Attached Base Sheet,Bonded Roof Cover 51
<br /> 7A Varlous Recover A-1 Bonded Insulation;Bonded Roof Cover 52-58
<br /> 7B Various Recover F Non-Insulated,Bonded Roof Cover 58
<br /> 7he followyn notes a I�to the svstems outlined herefn:
<br /> 1. The r of system evaluation herein pertains to above-deck roof componenu. Roof decks shall he in accordance with FBC requirements to the satisfaction of the AHJ. Load resistance of the
<br /> roof eck shall be documented through proper codified and/or FBC Approval documentation.
<br /> 2. Unles otherwise noted,fasteners and stress plates for insulation attachment shall 6e as follows. Fasteners shall be of sufflcient length for the following engagements:
<br /> ➢ Wood Deck: OMG p14 Roofgrip with Flat Bottom Plate(AccuVac),OMG HD with OMG 3 in.Galvalume Steei Plate,Dekfast N34 with Hex Ptate or 3"Round Insulatton Plate,Trufast HD with Trufast 3'
<br /> Metal Insulation Plates or FlintFast N14 Fastenerwith FIIntFast 3"Insulation Plates.Minimum 0.75-inch plywood penetratlon or minimum 1-inch wood plankemhedment.
<br /> > Steel Deck: OMG q12 or N14 Roofgrip wiih Recessed or Flat Bottom Plate(Accutrac),OMG p12 Standard or HD with OMG 3 in.Galvalume Steel Plate,Dekfast#12 or N14 with Hez Plate or 3"Round
<br /> Insulation Plate,Trufast'DP or HD with Trufast 3"Metal Insulation Pla[es or FlintFast N12 or H14 Fastener with flintFast 3"Insulation Plates. Minimum 0.75-Inch steel penetration and
<br /> engage the top flute of the steel deck.
<br /> i+ Concrete Deck: OMG#14 Roofgrip with Recessed or Flat Bottom Plate(Accutrac�,OMG HD or CD-30 with OMG 3 In.Galvalume Steel Plate,Dekfast p14 or DekSpike wlth Hex Plate or 3"Round
<br /> Insulation Plate,Trufast HD or CF with Trufast 3"Me[al Insulation Pla[es or FIIntFast k14 Fastener with FlintFast 3"Insulation Plates. Minimum 1-inch embedment. Fasteners installed
<br /> with a pilot hole In accordance with the fastener manufacturets pu6ltshed Installation Instructions.
<br /> ExtBrior Re earch and Design,LLC.d/b/a Trinity�ERD Evaluation Report 3520.03.04R17 for FU533-R16
<br /> Certiilcate�f.Authorization q9503 Revision 17•02/04/2016
<br /> Prepared b:Ro6ert Nieminen,PE•59166 Appendiz 1,Page 1 of 58