My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
16-17806
Zephyrhills
>
Building Department
>
Permits
>
2016
>
16-17806
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/19/2017 7:35:09 AM
Creation date
7/19/2017 7:35:08 AM
Metadata
Fields
Template:
Building Department
Building Department - Doc Type
Permit
Permit #
16-17806
Building Department - Name
TROYER DARVIN W REVOC TRUST
Address
38833 10TH AVE
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
12
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
,_ <br /> ,- c � � <br /> TABIE R402A• <br /> I <br /> BUILDING CdMPON6NT PRESCRIPTIVE REQUIREMENTS' INSTALLED VALUES <br /> � C�imato Zone t Ctimate Zone 2 <br /> Windows: U•Factor�0.652 U-Factor=0.40Z L/�Factor= . <br /> SMGC�U.28 SHCiC=D.25 $NUC= a �.CJ <br /> Skyllghts U-#aotor=0.75 U-factar=Q.fiS U-#actor= <br /> SHaC�0.30 SHGC=0.3p SHGC= <br /> Ooors:Exterior doar U•factor=0.H5' l�faGtor=0.4Q' (f�tactor= � Q <br /> Flaors: <br /> Slab-on-Gra�e NR NR �� <br /> Ovar uncondiiioned spaces" A-13 R-13 R•Value= <br /> Wai1s' Eut,and AdJ. �� <br /> Frame R-13 R-13 • R-Value� <br /> Mass <br /> insutatfon on ait interfor R-4 R-6 R-Vatua= <br /> Msuiation on�rait exteriar R-3 R-4. Fi-Value= <br /> Ceilings°• I R=30 R=38 R•Value= 8 <br /> AIr infiitration� 8tawer daar test is reguired on the buitding envelope to verify teakage_<5 ACH; Total teakage=ACH <br /> test repart provided to code oHiciei. Test re ort Attached? <br /> Yes No . <br /> Air disErlt�utlan system°: <br /> Air handtfng unit Not fltlowod in ottic Location: <br /> Duct R-val ie R•value_>R•8(supply in attiCs)or Z R-6(all olher duct locations)- R-Vaiue= ,[fj <br /> Atr Ieakage°� <br /> Duct test) Postconstruction tesh Total leal<age<_4 clm/100 s.L Totel leakage= i cfm/100s.f. <br /> Rough-In test Total leakege 5 3 cfml100 s.f. Test report Attached? Yes�No� <br /> Ducts in co�diYioned space Test not requfred it alt ducts and ANU are in candttioned space Lacation: <br /> Air condiUoni g system: MlNmum federai stendard required by NAECA°, '1, <br />� Central syste�S 65,q00 Btu/h SEER 13.0 SEER= f `-� <br /> i Raom uNt or�TAC EER jfrom Table C4Q3.2.3(3}j ��R, <br /> Other: See Tabtes G4032.3{7}-{11} <br /> Heating syste�n: Mlnimum tederal standard required by NAECAe <br /> Heat pump 5 65,000 6tu/h NSPF 7.?(belore it1t15);HSPF 8.2(as of t/7l15} NSPF g � � <br /> Gas fumace,�an-weathertzed AFUE 80°l AFUE_ � � � <br /> Ofi fumace,ni n-wealherized AFUE 83% AFUE_ <br /> Olher: ' <br /> Watsr heaUn�system(storage type}: M(nimum federai sfandard required by NAECAB C� <br /> Electric7 q0 gal:EF=0.92 Gallons= �7 <br /> 50 gel:EF=0.90 @F= t p O <br /> G2�1itPtlB dd gal:EF=0.59 fi�ations= �� <br /> 50 gal:EF=O.5S EF= <br /> Other(descri e): <br /> NR=No req irement. <br /> (1)Each component present in the As Proposed home must meet or exceed each of ttfe applicable performance criteria in order to oomply with this code using <br /> tbi9 mettrod. <br /> {2}For impac�raEed fenestration coiuplying with Secaon 22341..2.3.2 af the Ftorida Bttitding Code,Residentinl or Section 1649.1.2 of tha Florida B::ilding Cade, <br /> Building t e ma;cimum U-factor shall be 0.75 in Ciianate Zone l and 0.65 in Climate Zone 2.An area-wei;hted average of U-factor and SHGC shall ba <br /> accepted to meet the requirements,or up to 15 squaze feet of glazed fenestration area are exempted from the ,U-factpr and SHGC requirement based on <br /> SecEions 4Q2.3.1,R402.3.2 and R402.3.3. <br /> (3}One sida- inged opaque door assembty up to 24 squaze feet is exempted from tius U-factor requuement: <br /> (4)R-values e for insulation material only as applied in accordance with manufacturers' installatipn inswctions.Fnr mass walls, the "interior of wall"' <br /> tequiremept mvst be met except if at least SQ percent of tt�e insnlation zaquired for ihe"exterior of wa13"is instailed exterior of,or integral to,the wnii. <br /> (5)Ducts&AHU installed"substantiatly Ieak free"pet SecHon R443.2.2.Test requited by an energy tater certified in accardance with Section 553.99,Floridn <br /> Stntutes,04 as au[harized by Floridn 5tan�res.The total leakage testis qot required for ducts and air handlers located entirely within tha building thermal <br /> envelope.( <br /> {b}Minicnum a�ciencies aze thase sa by the Nntional Apfllial:ce E�:ergy Conservation�Act ot i98?for typica�residential equipment aad are subjact to i�1AECA <br /> niles and�regulations. For other types of equipmenC, see Tables C403.2.3(1-11) of the Commercial Provisions of the Florida Building Code, Energy <br /> Conserval�on. <br /> (7)Far other iec�ic srorage vo2umes,min.EF=0.97-{0.00232*volume}. <br /> (8)For other atural gas storage volumes,min.EF=0.67-(0.0019*volume). <br /> '�ABLE R402B MANDATORY REOUIREMENTS <br /> {�ompor�errt Sectlon Summary of Requ(tement(sj Chesk <br /> �, 'Ir leakage R4p2.4 To be caulked,gesketed,weatherstdpped or otherwise sealed per Table R402,4.1,1.Racessed lighting:IC•reted as <br /> having 5 2.0 c1m tested to ASTM E 283. <br /> Windows and doors:0.3 cfmtsq.ft{swinging daors:0.5 ctmtsf�when tesfed ta NFFiC 4Qd ar AAMAIWDMAtCSA 3011 <br /> I.S.7IA440. d'"� <br /> Flreplaces:Tlght-fitting flue dampers&outdoor combustlon air. <br /> ' fjtogrammabie fi403.t.2 Whera forcad-air lumace is primary systam,a programmable thermostat is requlred. <br /> � thermostat <br /> �ir dlsfibutlon sysiem R409.2.2 Ducts shall be tested to Section B03 of the RE5NET standards by an energy rater certltied in accordance w(th f <br /> R403.2.4 Sectlon 553.99,Flotida Statufes,or as authorized hy Rorida Statutes.Afr handiing uniis are not atfowed!n amcs. <br /> Water heaSars R4d3.4 Compiy with efticlencies tn Tab(e C4042.Hat water pipes insufated to>_R-3 to kitchen outlets,other cases. <br /> ClrculaUng systems to have an automaNc or accessible manual OFF swltch.Heat trap required for vertical pipe ✓ <br /> rlsers. <br /> �wimming poats&spas R4d3.9 Spas and hsated poots must have vapor-retardant wvers or a Ilquid cover ar other means proven to reduCe heat <br /> loss except it 70%of hcat from sita�recovered energy.ON/Nmer swltch raquired.Gas haaler minlmum lhertnal <br /> eBiciency is 82%.Heat pump pool healers minimum COP ia 4.0. <br /> tioaiingtheattng Rd03.8 3izing calculatian petfotmed&attached.Speciai occasion cooling or heating capacity requlres separate system or /' <br /> equlpment vadable capacity system. 1� <br /> l.ighting eqalQmant R404.1 At least 7S°/a of permanently installed IightinQlirctuees shali be htgh-efticacylamps. �/ , <br /> � - <br />
The URL can be used to link to this page
Your browser does not support the video tag.