<br /> , �
<br /> l •
<br /> . �
<br /> �� : R R W Building Consultants, Inc.
<br /> � � Consulting and Cngineering Services for the 13uilding Indiistq�
<br /> I B ' P.O.Box 230 Valrico.FL 33595 Pl�onc813.G529197 ' ,
<br /> � � Fl6ridal3oardofProfessionalEnpincersCertifcn�cofAuthorizuion�o.9813
<br /> I � � i ,�� � // / �
<br /> � f ' I �
<br /> � I . . . . . . . . .
<br /> Product Sub Category Manufacturer Product Name
<br /> Category
<br /> Associated Materials Inc. Model 3001/3B01/3A01/3A61
<br /> Window Doub le Hung 3773 State Road Extruded Vinyl
<br /> Cuyahoga Falls,OH 44223 Uouble Hung Wlndow
<br /> Phone 330.922.2108 "Sm•Med"Sash!"Non-Impact"
<br /> Scopel Product Evalua6an r2porE issued by R W Building Consultants,Inc.8�Lyndon F.Schmidt,P,E.(System ID#1998)for
<br /> Associated Materials Inc.,based on Rule Chapter IVo.61G20-3,Method 1D of the State of Florida ProductApproval;Dept.
<br /> of Susiness&Professional RegulaGon.
<br /> � RW Building Consultants and Lyndon F.Schmidt,P.E.do not have nor will acquire fnancial interest in the company
<br /> � manufacturing or distributing the product or in any other entity involved in the approval process of the product named herein.
<br /> �
<br /> �
<br /> Limitationsr
<br /> 1.Thisl product has been evaluated and is in compliance with the 5ih Edition(2014)Fl6rida Building Code structural requirements
<br /> excli ding the"High Velocity Hurricane Zone".
<br /> 2. Product anchors shall be as listed and spaced as shown on details.Anchor embedment to base material shall be beyond wall dressing
<br /> or stucco.
<br /> 3.Wh In used in areas requiring wind borne debris protection,this product is required to be protected with an impact resistant covering that
<br /> complies with Section 1809.1.2 of the Florida Building Code.
<br /> I
<br /> 4. For 2X stud construction,ar�choring of the assemblies shall be as shown for 2X buck masonry construction.
<br /> 5.Site Iconditions that deviate from the details of drawing FL-1172Q.14 require further engineering analysis by a licensed engineer or �
<br /> registered architec�
<br /> 6. See ldrawing�L-11720.14 for size and design pressure limitations.
<br /> Suppo�l ing Documents:
<br /> 1. Test Reaort No. Test Standard Testinq Laboratorv Siqned bv
<br /> ATI D2492.01-501117 AAMAlVNDMA/901/t.S.2/A440-08 Architectural Testing,Inc. Lynn Geo�ge
<br /> ATI D3073.01-109-47 AAMAlWDMA/101/I.S.2/A440-08 Architectural Testing,Inc. Michael D.Stremmel,P.E.
<br /> ATI D4961.06-501-47 A/�MAIWDMA/101/I.S.2/A440-08 Architectural Tesking,lnc. Lynn Geo�ge ,
<br /> ATI,D3479.06-501-47 AI.IMAIWDMA/101/I.S.2/A440-08 Architectural Testing,Inc. Lynn George �,
<br /> MT 3-0128-03-B AI�MAIWDMA/101/I.S.2/A440-08 M`f Group Wayne Breigtiner �
<br /> �
<br /> ' 2. Drawinq No. Prepared bv ' Siqned&Sealed bv
<br /> No.FL-11720.14 RVV Building Consultants,Inc.(CA#9813) Lyndon F.Schmidt,I?.E:
<br /> 3. C�Icu(afions Preaared bv Sianed 8 Sealed bv � '
<br /> Pr�ductAnchoring RIN Buildirtg Consultants,Inc.(CA#9813) Lyndon F.Schmidt,P.E. �
<br /> Bi c i Anchoring RW Building Consultants,Inc.(CA#9813) Lyriddn F.Schmidt,P_E. '
<br /> 4. t�ualitvAssurance �� �'�u�����'���,
<br /> �j'�^� ��`'i-!l�r; P -'p
<br /> Certificate of Participation issued by Architectural Testing,Inc.,certifying that ���°�,�..�;,�:�.��•.., �<J�.�,��
<br /> Associated Materials Inc.is manufacturing products within a quality '� `` °• �r;�`�°=�,� �i '
<br /> �ssurance program that complieS witF ISO/IEC 17020 and Guide 53. �' y°`���, � � � �i
<br /> �� � t�a c, �:;j� u 9 � � ,
<br /> � . , o� I
<br /> °r•�,� �
<br /> G; .�;°_ �._.,-;; `.,s� e;����� Lyndon F.Schmidt,P.E.
<br /> �,;;°a "'' ' " a ..t�, FL PE No.43409
<br /> •`;l`.`o! �;`1;.;f`��o`' 4/23/2015
<br /> i Sheet 1 of 1 ��<<•, `S, °, � ,'; .,� a'�,J�„
<br /> � L��l�I tf.���o� ,
<br /> i `�`c;�, -� i:(��— � �
<br /> e �`>`�
<br /> "fG��llLE!.{5.4�
<br />
|