<br /> Code Compliance: The product described herein has demonstrated compliance with the I
<br /> Florida Building Code 2014, Sections 1504.3.2, 1504.7.
<br /> Evaluation Report Scope: The product evaluation is limited to compliance with the structural wind load
<br /> requirements of the Florida Building Code 2014, as relates to Rule 61 G20-3.
<br /> Performance Standards: The product described herein has demonstrated compliance with:
<br /> • UL 580-06-Test for Uplift Resistance of Roof Assemblies
<br />� • UL 1897-04- Uplift Test for Roof Covering Systems.
<br />� • FM 4471-199�, Section 4.4 Foot Traffic Resistance Test
<br /> Reference Data: 1 UL 580-94/1897-98 Uplift Test
<br /> Force Engineering &Testing, Inc. (FBC Organization #TST-5328)
<br /> Report No. 117-0407T-09, Dated 11/16/09
<br /> 2. FM 4471-95, Section 4.4 Foot Traffic Resistance Test
<br /> Force Engineering &Testing, Inc. (FBC Organization #TST-5328)
<br /> Report No. 117-0238T-09E, Dated 07/21/2009
<br /> 3. Certificate of Independence
<br /> By Dan Kuhn, P.E. (FL#75519)Q Kuhn Engineering, LLC
<br />, (FBC Organization#ANE ID: 10743)
<br /> Test Standard Equivalence: 1. The UL 580-94 test standard is equivalent to the UL 580-06 test standard.
<br /> 2. The UL 1897-98 test standard is equivalent to the UL 1897-04 test
<br /> standard.
<br /> 3. The FM 4471-95 test standard is equivalent to the FM 4471-1992 test
<br /> standard.
<br /> Quality Assurance Entity: The manufacturer has established compliance of roof panel products in
<br /> accordance with the Florida Building Code and Rule 61 G20-3.005(3)for
<br /> manufacturing under a quality assurance program audited by an approved quality
<br /> assurance entity.
<br /> Minimum Slope Range: Minimum Slope shall comply with Florida Building Code 2014, including
<br /> Section 1507.4.2 and in accordance with Manufacturers recommendations. For
<br /> slopes less than 3:12, lap sealant must be used in the panel side laps.
<br />, Installation: Install per Manufacturer's recommended details.
<br /> Underlayment: Shall comply with Florida Building Code 2014 section 1507.4.5.1 and 1507.4.5.2.
<br /> F #11651.27 R2•1UNE 15,2015