Laserfiche WebLink
� - � <br /> FL 7271.9-R3 I <br /> C1999-17 <br /> 3.20.15 <br /> Page 2 of 3 <br /> Manufacturer: Union Corrugating Company <br /> Product Name: MasterRib Panel <br /> Panel Description: 36"wide coverage with 3/4"high ribs at 9" o.c. <br /> Materials: Minimum 29 ga., 80 ksi steel. Galvanized coated steel (ASTM A653) <br /> or Galvalume coated steel (ASTM A792) or painted steel (ASTM <br /> A755). <br /> New Underlayment: Minimum underlayment as per FBC 2007 Section 1507.4.5.1. <br /> Required for new construction and optional for reroofing construction. <br /> Existing Underlayment: One layer of asphalt shingles over one layer of#30 felt. For reroofing <br /> (Optional) construction only. <br /> Deck Description: Min. 15/32" thick APA rated plywood or min. 3/4" thick wood plank <br /> (min SG of 0.42) for new and existing constructions. Designed by <br /> others and installed as per FBC 2014. <br /> Slope: 1/2:12 or greater in accordance with FBC 2014 Section 1507.4.2 <br /> Design Uplift Pressure: 45.0 psf @ fastener spacing of 24" o.c. <br /> (Factor of Safety=2) 113.1 psf @ fastener spacing of 12" o.c. <br /> Panel Attachment: #9-15 or#10-14 x 1.5" long wood screw with washer <br /> At panel ends @ 5.5"-3.5"-5.5" o.c. across panel width <br /> At intermediate @ 9" o.c. across panel width <br /> Sidelap Attachment: 1/4"-14 x 7/8" long SDS with washer @ max 24" o.c. <br /> Test Standards: Roof assembly tested in accordance with UL580-94 `Uplift Resistance <br /> of Roof Assemblies', TJL1897-98 `Uplift Tests for Roof Covering <br /> Systems' and FM 4470 Section 5.5 `Resistance to Foot Traffic'. <br /> Code Compliance: The product described herein has demonstrated compliance with FBC <br /> 2014 Section 1507.4 <br /> Product Limitations: Design wind loads shall be determined for each project in accordance <br /> with FBC 2014 Section 1609 or ASCE 7-10 using allowable stress <br /> design. The maximum fastener spacing listed herein shall not be <br /> exceeded. This product is not approved for use in the High Velocity <br /> Hurricane Zone. Fire classification is not within scope of this <br /> Evaluation Report. Refer to FBC 2014 Section 1505 and current <br /> approved roofing materials directory or ASTM E108/UL790 report <br /> from an accredited laboratory for fire ratings of this product. <br />