My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
16-17881
Zephyrhills
>
Building Department
>
Permits
>
2016
>
16-17881
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/20/2017 7:48:55 AM
Creation date
7/20/2017 7:47:57 AM
Metadata
Fields
Template:
Building Department
Company Name
LIVINGFOODS OASIS LLC
Building Department - Doc Type
Permit
Permit #
16-17881
Building Department - Name
LIVINGFOODS OASIS LLC
Address
38201 10TH AVE
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
25
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
-, <br /> Chapter 3-System Design <br /> Page 3-2 � � <br /> Revision 5 1 <br /> � <br /> � FOR CIRCUMFERENCES 0 to 50°(0-127 cm): � <br /> i MAXIMUM DIAMETER SHALL NOT EXCEED <br /> � I 16"(41 cm); \\ I <br /> - --- --- FOR GIRCUMFERENCES 0 to 150"(0381 cm) aERIME7ER <br /> NOZZLE TIP � �USlNG THE N-2W:MAXIMUM DIAMETER MEA9UREMENT—� ------- � <br /> GENTERED, � � SHALL NOT EXCEED 47-112"(121 cm). 1/2 WAY INTO <br /> AIMED INTO DUCT TRANSITION <br /> NOZZLETIPCENTERED, I NOZZLETIPCENTERED, � � I <br /> AIMED INTO DUCT � AIMED INTO DUCT <br /> ' � „Zw � , Figure 3.3. <br /> � ---, W � ��2 W�, Proper Measurement And Nozzle <br /> -- --- -- -------- - <br /> ; (� ; � Placement For Larger To Smaller Transition Ducts. <br /> lT�—t/2 L I-�-112 L-r <br /> l�—��� `-'" Smaller to Larqer Duct Transitions <br /> FOR PERIMETERS 0 to 50"(0-727 cm):LONGEST SIDE <br /> SHALL NOT EXCEED 16-3f4"(42.5 cm); <br /> FOR PERIMETERS 0 to 150"(0381 cm)USING THE To determine the ro er covera e for ducts that have a <br /> N-2W:LONGEST SIDE SHALL NOT EXCEED 50"(127 cm). P p 9 <br /> VIEW OF DUCT CROSS-SECTIONAL AREA smaller opening into the plenum than the final exhaust <br /> duct, measure the perimeter of the final exhaust,duct. <br /> Figure 3-2. The nozzle will be located as per standard duct <br /> Proper Duct Nozzle Placement coverage at the duct/plenum intertace and aimed at the <br /> center of the duct opening. See Figure 3.4 <br /> The Model N-2W noule is a two (2) flow point nozzle <br /> that can protect a square or rectangular duct of FERIMETER _I___ <br /> MEASIIREMENT � <br /> unlimited length and changes of direction with a � <br /> maximum 150" (381 cm) perimeter and a maximum one I <br /> side length of 37-1/2"(95 cm) (square)and 50" (127 cm) � <br /> (rectangular) respectively. It can also protect a round � <br /> duct with a maximum circumference of 150" (381 cm) <br /> (47-1/2" (121 cm) maximum diameter) See Figure 3-1 Figure 3.4. <br /> and 3-2. Proper Measurement And Nozzle <br /> Placement For Smaller To Larger Transition Ducts. <br /> Ducts Larqer than 150" (381 cm) Perimeter Upper/Lower Plenums <br /> For ducts with perimeters larger than 150° (381 cm), <br /> more than one Model N-2W nozzle must be used. When protecting exhaust hoods with multiple risers <br /> When using multiple Model N-2W noules to protect a (upper / lower plenums), each riser must be protected <br /> single duct, the cross sectional area of the duct must be as an individual duct. See Figure 3.5 <br /> divided into equal symmetrical areas. Each nozzle must � � <br /> then be installed in the center of the area it is protecting <br /> and aimed directly into the duct opening. No,cross <br /> sectional area can exceed the sin le nozzle covera e. � <br /> 9 9 _ � � � � � DUCT <br /> �I�� ! <br /> Transition Ducts ' — <br /> PLENUM <br /> Protection of any non-standard duct should be Figure 3.5. <br /> discussed and agreed upon with the local authority Upper 1 Lower Plenum Protection <br /> having jurisdiction before proceeding with any system Electrostatic Precipitators <br /> installation. Typically, transition ducts are protected in <br /> the following manner <br /> , Ventilation systems that utilize electrostatic precipitators <br /> Larqer to Smaller Duct Transitions require duct protection above and below the precipitator. <br /> Standard duct nozzles are used for this application. <br /> To determine the proper coverage for ducts that have a See Figure 3.6. � , <br /> NOIILE <br /> larger opening into the plenum than the final exhaust <br /> , duct, measure the perimeter of the duct half way <br /> between the largest and smallest cross sectional areas. I` � PRECIPITATOR <br /> The nozzle will be located as per standard duct ��' <br /> coverage at the ducUplenum intertace, rather than at the � No���E PLENUM <br /> - point of ineasurement, and pointed into the duct, aimed � _� � <br /> at the center of the final.duct opening. See Figure 3.3. Figure 3.6. <br /> Electrostatic Precipitator Protection. <br /> r ULEX 6885 ULC-EX 6885 BPN: BFR-TM <br /> January 1, 2013 � <br />
The URL can be used to link to this page
Your browser does not support the video tag.