My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
16-17897
Zephyrhills
>
Building Department
>
Permits
>
2016
>
16-17897
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/20/2017 8:22:56 AM
Creation date
7/20/2017 8:22:51 AM
Metadata
Fields
Template:
Building Department
Company Name
SILVER OAKS
Building Department - Doc Type
Permit
Permit #
16-17897
Building Department - Name
PRILLIMAN,LANI C
Address
6402 HUNTINGTON DR
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
39
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
- S-T�E-RI�ARCHII'ECTURAL SYSTEMS � <br /> HVHZ CLIPPED ALUMINUM TUBE MULLIONS <br /> GENERALNO7E5. �'Wl'� 4 'WZ' I �'Wl'�'W2'—{ <br /> 1. THE PRODUCT SHOWN HEREIN IS DESIGNED AND MANUFACTURED TO COMPLY WITH THE 2010&Sth EDITION � � I f <br /> FLORIDA BUILDING CODE,INCLUDING THE HIGH VElOC17V HURRICANE ZONE. <br /> i <br /> 3. APPROVED IMPAR PROTERIVE SYnEM IS NOT REQUIRED FOR THIS PRODUR IN WIND BORNE DEBRIS REGIONS 4 / �� / \� F �6 MULL <br /> INDIVIDUAL UNffS ATTCHED TO MULLIONS MUST BE IMPACT RATED � �� $ j SPAN'L' <br /> ANCHOR CLIP, /� �\ I <br /> 4. ADEQUACY OF THE ExISTING STRUGTURAL CONCRETE/MASONRY AND 2X FRAMING AS A MAIN WIND FORCE <br /> RESISTING SYSTEM CAPABIE OF WITHSTANDING AND TRANSFERRING APPLIED PRODUCT LOADS TO THE �P �/ � � � t <br /> FOUNDATION IS THE RESPONSIBILITY OF THE ENGINEER OR ARCHITECT OF RECORD FOR THE PROIECT OF <br /> '"ST"��,T'°". VERTICAL SPAN <br /> S. 1%AND 2X BUCKS(WHEN USED)SHALL BE DESIGNED AND ANCHORED TO PROPERLY TRANSfER ALL LOADS TO THE // /� VERTILAL MULL <br /> STRUCTURE.BUCK DESIGN AND INSTALLATION IS THE RESPONSIBIIITV OF THE ENGINEER OR ARCHITECT OF RECORD q SPAN'L' �SPAN�'L'� <br /> FOR THE PROIER OF INSTALLATION. <br /> MULLION } <br /> 6. THE INSTALLATION DETAILS DESCRIBED HEREIN ARE GENERIC AND MAY NOT REFLECT ARUAL CONDITIONS FOR A 7YP % % �� � <br /> SPECIFIC SITE.IF SITE CONDITIONS CAUSE INSTALLATION TO DEVIATE FROM THE REQUIREMENTS DETAILED HEREIN, �WZ� <br /> A LICENSED ENGINEER OR ARCHITECT SHAIL PREPARE SITE SPECIFIC DOCUMENTS f-0R USE WITH THIS DOCUMENT IN �� �� � <br /> NON-HVHZ AREAS.IN HVHZ AREAS,ONE TIME PRODUCT APPROVALTO BE OBTAINED FROM MIAMI-DADE PERA. � � <br /> 7 MULLION&CLIP MATERIAI.ALUMINUM 6005-TS&6063-T6(AS NOTED) <br /> 8. MULLIONS MAY BE USED WITH ANY APPROVED FENESTRATION PRODUCT,UNDER SEPARATE APPROVAL. �� �� p Wl <br /> 9. SEE SHEETS 5-9 FOR INSTALLATION ANCHOR REQUIREMENTS FOR SPECIFIC ANCHORING REQUIREMENTS,MULLION � <br /> CONFIGURATIONS,AND DESIGN LOAD CAPACRIES. ANLHOR LLIP,� A <br /> S0. IN ACCOftDANCE WITH THE 2010&STH EDITION FBC,DISSIMILAR METALS INCLUDING FASTENERS THAT MAY COME �P 4 <br /> INTOCONTACTWITHALUMINUMUNITFRAMINGSHALLBEPROTEREDASDEFINEDINSEC2003.8.4. �PICAL MULLION ASSEMBLY HORIZONTAL��T�� MULL SPAN <br /> MULL <br /> INSIRUCTIONS. �SPAN'L'� <br /> 1. DETERMINE REQUIRED DESIGN PRESSURE FOR OPENING. � � <br /> 2. CHOOSE A MULLION THAT PROPERLV FITS THE FENESTRATION PRODUCT 'W2' <br /> TABLEOFCONTENTS 3. DETERMINEWHETHERASSEMBLYREQUIRESONE-WAYORTWO-WAYMULLIONS: y1 � <br /> • ASSEMBLIES CONSISTING OF STACKED OR SIDE-BY-SIDE UNITS REQUIRE USE OF � <br /> SHEET REVISION SHEETDESCRIPTION ONE-WAYMULLIONS. p <br /> • ASSEMBLIES CONSISTING OF MULTIPLE UNITS MULLED TOGETHER WITH <br /> � - GENERAL NOTES,INSTRUCTIONS,AND ELEVATIONS MULTIPLE MULLIONS REQUIpE USE OF TWO-WAY MULLIONS. <br /> • SEE SHEET 11 FOR ASSEMBLYAND LOAD E7(AMPLES. p � �WI� <br /> 2 - MULLION DETAILS • IF ASSEMBLY TYPE CANNOT BE DETERMINED USE TWO-WAY MULLION CHART. I <br /> 4. VERIFY THAT MULLION DESIGN PRESSURE MEETS OR EXCEEDS REQUIRED DESIGN j <br /> 3 - ANCHOR CLIP DETAILS PRESSURE Of OPENING USING CHARTS ON SHEETS 6-10. f� � <br /> 4 - MULLIONSECTIONS 5. QUALIFIEDCIIPNPESAPPEARONSHEET56-lO.MULTIPLEANCHOR <br /> TYPE/SUBSTRATE/CIIP COMBINATIONS WITHIN AN OPENING ARE ALLOW ED. <br /> 5 - TYPICAL MULLION 6 CLIP ASSEMBLIES 6. THE IESSER DESIGN PRESSURE OR MULLION OR FENESTRATION PftODUCT WILL HORIZO NTAL SPAN <br /> GOVERN OVERALLASSEMBLY DESIGN PRESSURE RATING. <br /> 6 - 1"X 3-1/8"(LIGHn MULLION DESIGN LOAD TABLES <br /> 7 - 1"X 3-1/8"(NEAVY)MULLION DESIGN LOAD TABLES <br /> 8 - I"X 4"MULLION DESIGN LOAD TABLES `�1111I�!f/� REVISIONS EASTERNARLHRELTORALSYSTEMS <br /> 9 - 2"X 4"MULLION DESIGN LOAD TABLES ��(����S F ������� '• Eastern ensreRNnMEfFL SYPP�Y <br /> �� - \``` � �� '% ��w�^n�r Iw1.:�•.��i�i a 00]00FVRRIAROAO <br /> 2"X b"MULLION DESIGN LOAD TABLES � !v . ' ,.�.p i ,,_;� w„��„�',�.;; FORTMYERS,FIARIDA]]91] <br /> ' �. ,•'•• . 0 � .. . eao-e3anoa <br /> �l - MULLION ASSEMBLY AND LOAD EXAMPLES i•, � T�T�� hJ <br /> — 7$_.. — HVHZ CLIPPED ALUMINUM TUBE MULLIONS <br /> -�' . ' * = VERTICAL AND HORIZONTAL CONFIGURATIONS <br /> _ � • T T : � = GENERAL AND INSTALLATION NOTES <br /> ' �1 =./ P �4�` OATE:DRAWN BY: PflEVRREO BV: <br /> Digitally signed by Hermes F.Norero,P.E. : o,�,•., t�o�,•'`� 02 os i3 TJH <br /> j�� • N � G�`\� OMWINGNO SLRL£: f� FB ECEGTIFIC 1EOF <br /> Reason:I am approving this document i���� ��,�1��� PA-0003 N.T.S. �4�,p. AUTHORIZ�TIONN0.295)B <br /> Date:2015.02.28 12:45:10-05'00' �E�DANIRB/AO�iI��W� 8 BV DATE DESCRIPfION � REV 5M1 �OC ,1 R�� <br /> YNdSi1 <br />
The URL can be used to link to this page
Your browser does not support the video tag.