Laserfiche WebLink
Pro ect Summa Job: R1076412 <br /> -�- v right�oft� � � Date: 70-2416 <br /> Entire House By: TMN <br /> Bahr's Propane Gas &AC Inc <br /> 4441 Allen Rd,Zephyrhills,FL33541 Phone:813-782-5013 <br /> � • ' • • <br /> For: Typical- End Units &1 and 8-6 <br /> 4408 Court St, Zephyrhills, FL 33542 <br /> Notes: Load Calculation was obtained from an on-site inspection. <br /> � - � � • <br /> Weather: Lakeland Co(S), FL, US <br /> Winter Design Conditions Summer Design Conditions <br /> •utside db 41 °F Outside db 91 °F <br /> I side db 70 °F Inside db 75 °F <br /> esign TD 29 °F Design TD 16 °F <br /> Daily range M <br /> Relative humidity 50 % <br /> Moisture difference 47 gr/Ib <br /> Heating Summary Sensible Cooling Equipment Load Sizing <br /> $tructure 13081 Btuh Structure 12283 Btuh <br /> Qucts 3379 Btuh Ducts 5710 Btuh <br /> entral vent(0 cfm) 0 Btuh Central vent(0 cfm) 0 Btuh <br /> umidification 0 Btuh Blower 1416 Btuh <br /> iping 0 Btuh <br /> quipment load 16460 Btuh Use manufacturer's data y <br /> I Rate/swing multiplier 1.00 <br /> Infiltration Equipment sensible load 19409 Btuh <br /> ethod Simplified Latent Cooling Equipment Load Sizing <br /> �onstruction quality Average <br /> ireplaces 0 Structure 3550 Btuh <br /> Ducts 1274 Btuh • <br /> Heating Cooling Central vent(0 cfm) 0 Btuh <br /> �rea(ftZ) 1435 1435 Equipment latent load 4824 Btuh <br /> olume(ft') 11480 11480 <br /> ,ir changes/hour 0.45 0.23 Equipment total load 24233 Btuh <br /> Equiv.AVF(cfm) 86 44 Req.'total capacity at 0.75 SHR 2.2 ton <br /> Heating Equipment Summary Cooling Equipment Summary <br /> ake Make Tempstar or Eqv. <br /> �rade Elec. Heat Trade TEMPSTAR <br /> Model Cond N4A330A�G)KC* <br /> AHRI ref Coil FXM4X30 A* <br /> AHRI ref 3692289 <br /> fficiency 100 EFF Efficiency 11.5 EER, 14 SEER <br /> , eating input 8.0 kW Sensible cooling 20850 Btuh <br /> �eating output 27297 Btuh Latent cooling 6950 Btuh <br /> emperature rise 96 °F Total cooling 27800 Btuh <br /> ctual air flow 261 cfm Actual air flow 927 cfm <br /> ir flow factor 0.016 cfm/Btuh Air flow factor 0.052 cfm/Btuh <br /> tatic pressure 0.50 in H20 Static pressure 0.50 in H20 <br /> pace thermostat Load sensible heat ratio 0.80 <br /> Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. <br /> ,` wri t�tsoft" 20160ct-25 14:06:39 <br /> � Right-SuiteCSl Universal 2017 17.0.09 RSU07440 PaBe� <br /> � .. QuadPlex-4408 Court St\R1016412 Unit&1.rup Calc=MJB Building Front faces: W � <br /> ' i <br />