Laserfiche WebLink
.. - -- --- � <br /> . � <br /> F �405-2014 <br /> FLORID�► ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION <br /> Flo�ida Department of Business and Professional Regulation - Residential PerFormance Method <br /> Project N me: R1016412 Unit 8-1 and 8-6 Builder Name.' Butterfield �i <br /> Street: 4408 Court St Permit Office: City of Zephyrhills Q �y <br /> City,Stat ,Zip: Zephyrhills,FL,33542 Permit�Number: J �rJ 03 t' %�]!0 / <br /> Owner: � Typical-End Units 8-1 and 8-6 Jurisdiction: 611600 <br /> Design L cation: FL,Tampa County:: Pasco(Florida Climate Zone 2) <br /> 1. New co struction or existing New(From Plans) 9. Wall Types(1085.3 sqft.) Insulation Area i <br /> 2. Single f mily or multiple family Single-family a.ConGrete Block-Ext Insul,Exterior R=5.0 898.67 ft� I <br /> b.Frame-Wood,Adjacent R=13.0 186.67 ft <br /> 3. Numbe of units,if multiple family 1 c.N/A R {�2 <br /> 4. Numbe of Bedrooms 3 d.N/A R= ft� <br /> 10.Ceiling Types (1435.0 sqft.) Insulation Area <br /> 5. Is this worst case? No a.Under Attic(Vented) R=30.0 1435.00 ft2 <br /> 6. Conditi ned floor area above grade(ft� 1435 b.N/A R= ft2 <br /> Conditioned floor area below grade(ft� 0 c.N/A R= ft2 <br /> 11.Ducts R ftZ <br /> 7. Windol (137.0 sqft.) Description Area ' a.Sup:Attic,Ret:Attic,AH:ah 6 175 <br /> a. U-F ctor: Dbl,U=0.30 137.00 ft� <br /> SH C: SHGC=0.25 <br /> b. U-F ctor: N/A {�z 12.Cooling systems kBtu/hr Efficiency <br /> SH� C: a.Central Unit 27.8 SEER:14.00 <br /> c. U-F ctor: N/A ftz <br /> SH C: 13.Heating systems kBtu/hr Efficiency <br /> d. U- actor: N/A ft2 , a.Electric Strip Heat 27.3 COP:1.00 <br /> SH C: <br /> Area Ieighted Average Overhang Depth: 1.672 ft. <br /> Area Weighted Average SHGC: 0.250 14 Hot water systems <br /> a.Electric Cap:40 gallons <br /> 8. Floor ypes (1435.0 sqft.) Insulation Area EF:0.970 <br /> a.Sla -On-Grade Edge Insulation R=0.0 1435.00 ftz b. Conservation features � <br /> b.N/ ' R= ft2 None <br /> c.N/ R= ftZ 15.Credits CF,Pstat <br /> Glass/I IoorArea: 0.095 Total Proposed Modified Loads: 44.53 pASS <br /> Total Baseline Loads: 46.69 <br /> I hereb certify that the plans and specifications covered by Review of the plans and ��'C���'`���. <br /> this cal ulation are in compliance with the Florida Energy specifications covered by this =$ �, . <br /> .�' �'%. +;�.� -� <br /> Code. ��/�� calculation indicates compliance g -,�� ,��!�' <br /> wit h t he F lori da Energy Co de. �» �r��,, '� k�;:'r,.��"„f <br /> �t' � � <br /> PREP RED BY: Before construction is completed c�: ' <br /> DATE 10-25-16 this building will be inspected for � i���'' T ;. � <br /> compliance with Section 553.908 � �; <br /> I here y certify that this building,as designed, is in compliance Florida Statutes. ,�,� . �,�, <br /> with th Florida Energy Code. �',t3''�''�' . <br /> OWN R/AGENT:_ BUILDING OFFIC AL: <br /> DAT : DATE: � <br /> - Co pliance requires certification by the air handler unit manufacturer that the air handler enc sure qualifies as <br /> ce fied factory�ealed in accordance with R403.2.2.1. <br /> -Co pliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and an envelope leakage <br /> test r port in accordance with R402.4.1.2. <br /> 10/ 5/2016 2:01 PM EnergyGauge�USA-FlaRes2014 Section R405.4.1 Compliant Software Page 1 of 5 <br />