Laserfiche WebLink
i , <br /> `. � . � . , <br /> FO�M R405-2014 <br /> ,FL,ORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION <br /> � <br />�I i lorida Department of Business and Professional Regulation - Residential Performance Method <br /> Project Name: Hayden 4EHB Elev D Builder Name: DRFi Express Homes <br /> Street: 3Cp ��+� �p��C�. Permit Office: <br /> City,�State,Zip: Zeph�s, FL,����/ ' / Permit Number: <br /> Owner: S V Jurisdiction: <br /> Design Location: FL,Tampa �/ County:: Pasco(Florida Climate Zone 2) <br /> 1. Ne�I construction or existing New(From Plans) 9. Wall Types(2614.2 sqft.) Insulation Area <br /> 2. Single family or multiple family Single-family a.Frame-Wood, Exterior R=11.0 1285.30 ftz <br /> b.Concrete Block-Int Insul, Exterior R=4.1 996.67 ftz <br /> 3. Number of units,if multiple family 1 c.Frame-Wood,Adjacent R=11.0 332.22 ft2 <br /> 4. Numl ber of Bedraoms 5 d.N/A R_ ft2 <br /> � 10.Ceiling Types (1541.0 sqft.) Insutation Area <br /> 5. Is t I is a worst case? No a.Under Attic(Vented) R=30.0 1541.00.ftz <br /> 6. Co ditioned floor area above grade(ftz) 2605 b.N/A R= ft2 <br /> Co�ditioned floor area below grade(ftz) 0 c.N/A R= ft2 <br /> 11.Ducts R ftz <br /> 7. Windows(250.0 sqft.) Description Area a.Sup:Attic,Ret:2nd Floor,AH:2nd Floor 6 261 <br /> a. �-Factor: Dbl, U=0.34 210.00 ftz <br /> HGC: SHGC=0.31 <br /> b. �-Factor: Dbl,U=0.55 40.00 ft2 12•Cooling systems kBtu/hr Efficiency <br /> HGC: SHGC=0.34 a.Central Unit 40.0 SEER:14.00 <br /> c. �-Factor: N/A ftz <br /> � <br /> HGC: 13.Heating systems kBtu/hr Efficiency <br /> d. �i-Factor. N/A ftz a.Electric Heat Pump 41.0 HSPF:8.20 <br /> SHGC: <br /> Are2 Weighted Average Overhang Depth: 1.692 ft. <br /> Are��Weighted Average SHGC: 0.315 14.Hot water systems <br /> � a.Electric Cap:50 gallons <br /> S. Flo r Types (1541.0 sqft.) Insulation Area <br /> a.Slab-On-Grade Ed e Insulation R=0.0 1104.00 ftz EF:0.950 <br /> 9 b. Conservation features <br /> b.Raised Floor R=19.0 437.00 ftz None <br /> c.NiA R= ft2 15.Credits Pstat <br /> �I Total Proposed Modified Loads: 78.64 - <br /> Glass{Floor Area: 0.096 <br /> Total Baseline Loads: 79.15 PASS <br /> �I <br /> I here�y certify that the plans and specifications covered by Review of the plans and 0�^�HE�TA� <br /> this calculation are in compliance with the Florida Energy specifications covered by this -� = � p <br /> Code. calculation indicates compliance �/„��'''':� __--'�,o �,+ <br /> with the Florida Energy Code. ti n„.��,,,,'-y.�,=�',.;���„rO� <br /> PRE iARED BY: � Before construction is completed <br /> ` rj,F;_ _... C <br /> DAT : ,U'�, - this building will be inspected for � �����- ,3,, <br /> compliance with Section 553.908 * � ° � <br /> I hereby certify that this building, as designed,is in compliance Florida Statutes. j� �,S <br /> with thll Florida Energy Code. �QD��R� <br /> OWN�R/AGENT• BUILDING OFFICIAL: <br /> DATE: DATE: <br /> - Co I pliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as <br /> certified factory-sealed in accordance with R403.2.2.1. <br /> -Com� liance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and an envelope leakage <br /> test re ort in accordance with R402.4.1.2. , <br /> 1 0/27 201 6 2:09 PM EnergyGaugeC�USA-FlaRes2014 Section R405.4.1 Compliant Software Page 1 of 5 <br /> � � <br />