Laserfiche WebLink
i• . . " � <br />� FO M R405-2014 <br />� �Li0�6DA ElNE�GY EFFAC9�NCl( CODE E'OB� �dJeLDING CONSTRUC�00� <br /> Florida Department of Business and Professional Regulation - Residential Performance Method <br /> Projeet Name: Galen Elevation D Buiider Name: DRH Express Homes <br /> Stree{: 3���] (���i � Q���j�- Permit Office: <br /> e Zi • Ze h rhills� . Permit Number: <br /> City, �utat , p. p y , <br /> , .�� � <br /> Owne�r: � � Jurisdiction: <br /> Desig Location: FL,Tampa � �County:: Pasco(Florida Climate Zone 2) <br /> I <br /> 1 New construction or existing New(From Plans) 9. Wall Types(2511.6 sqft.) Insulation Area <br /> 2. Sing e family or multiple family 5ingle-family a. Frame-Wood,Exterior R=11.0 1269.30 ftz <br /> b.Concrete Block-Int Insul,Exterior R=4.1 356.22 ftz <br /> 3. Nu Iber of units,if multiple family 1 c. Frame-Wood,Adjacent R=11.0 286.00 ftz <br /> 4. Nu Iber of Bedrooms 4 d.,N/A R= ft2 <br /> I 10.Ceiling Types (1451.0 sqft.) Insulation Area <br /> 5. is th s a worst case? No a.Under Attic(Vente� R=30.0 1451.00 ftz <br /> 6. Conditioned fioor area above grade(ftz) 2432 b. N/A R= ftz <br /> z <br /> Con I itioned floor area below grade(ftz) 0 11 cDucts R R ftz <br /> 7. Win�ows(229.0 sqft.) Description Area a.Sup:Attic,Ret:2nd Fioor,AH:2nd Floor 6 231 <br /> a. U�Factor: Dbl,U=0.34 189.00 ftz <br /> Si�iGC: SHGC=0.31 <br /> h. U�r Factor: Dbl,U=0.55 40.00 ftz 12.Cooling systems kBtu/hr Efficiency <br /> SHGC: SHGC=0.34 a.Central Unit 33.8 SEER:14.00 <br /> c. Uj�Factor: N/A ftz <br /> S�HGC: 13.Heating systems kBtu/hr Efficiency <br /> d. U,�Factor: N/A ftz a.Electric Heat Pump 33.8 HSPF:8.20 <br /> S GC: <br /> Area�Weighted Average Overhang Depth: 1.585 ft. <br />�, Area Weighted Average SHGC: 0.315 14 Hot water systems <br /> � a.Electric Cap:50 gallons <br /> 8. Fioo Types (1451.0 sqft.) Insulation Area <br /> a.SI� -On-Grade Ed e Insulation R=0.0 1019.00 ft2 EF•0.950 <br /> 9 6. Conservation features <br /> b. FI��or over Garage R=19.D 432.00 ftz None <br /> c.N IA R= ftz 15.Credits Pstat <br /> I <br /> � Total Proposed Modified Loads: 71.98 � p c c <br /> Glassl Floor Area: 0.094 Total Baseline Loads: 74.48 f1`�`� <br /> I here y certify that the pians and specificafions covered by Review of the plans and ��Tk��?',q?,� <br /> this ca culation are in compfiance with the Florida Energy specifications covered by this y ��� =�� fl� <br /> Code. calculation indicates compliance ��r, 4 =';�`�""s't <br /> with the Florida Energy Code. h rrrt,.�,.��%•,".;:r,��.;;,.�„ O� <br /> PREP� RED BY: ����- Before construction is completed w �' '�' _'""�' " <br /> � ^;r', _. t7 . <br /> DATEI /O `2g-1� this buiiding will be inspected for � � � �,, <br /> compliance with Section 553.908 * � <br /> I hereb certify that�this building, as designed, is in compliance Florida Statutes. .t�� �� <br /> with thi Florida Energy Code. QD y�`fi� <br /> OWN�WAGEN : BUILDING OFFICIAL: <br /> DATEi� /A �� -,� DATE: <br /> - Com liance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as <br /> certi�ied factory-sealed in accordance with R403.2.2.1. <br />, -Com� liance requires an Air Barrier and Insulation Inspection Checkiist in accordance with R4Q2.4.1.1 and an envelope leakage <br />, test re ort in accordance with R402.4.1.2. <br /> 10/28 2016 8:30 AM EnergyGauge�USA-FlaRes2014 Section R405.4.1 Compliant Software Page 1 of 5 <br /> I <br /> _ ; <br />