Laserfiche WebLink
� <br /> � , i _ <br /> FOR�� R405-2014 <br /> FL�RIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION <br /> Florida Department of Business and Professional Regulation - Residential Performance Method <br /> II <br /> Project Name: Cali E evation D w gara e s les office Builder Name: D envve �(1J� ��kC� <br /> Street: �3����I J������ ,� ��Q� Permit Office: ��cP�forl�i/�S <br /> City,Stl te,Zip: Zephyrhills,F��3 J!(�! Permit Number• /��f3.�i <br /> Owner:� S(l Jurisdiction: �//(�0� <br /> Design Location: FL,Tampa Z/� County:: pasco(Florida Climate Zone 2) _ <br /> 1. New i nstruction or existing New(From Plans) 9. Wall Types(1811.3 sqft.) Insulation Area <br /> 2. Single family or multiple family Single-family a:Concrete Block-Int Insul,Exterior R=4.1 1699.30 ftz <br /> � b.Frame-Wood,Exterior R=11.0 112.00 ftz <br /> 3. Numb r of units,if multiple family 1 - c.N/A R= ftz <br /> 4. Numbl r of Bedrooms � 4 d.N/A R_ ftZ <br /> 5. Is this a worst case? No 10.Ceiling Types (2258.0 sqft.) Insulation Area <br /> a.Under Attic(Vented) R=30.0 2258.00 ftz <br /> 6. Condi ioned floor area above grade(ft2) 2258 b.N/A R= ft2 <br /> Condi ioned floor area below grade(ftz) 0 c.N/A R= ftz <br /> 11.Ducts R ftz <br /> 7. Wind s(231.8 sqft:) Description Area a.Sup:Attic,Ret:Main,AH:Main 6 366 � <br /> a. U-I actor: Dbl,U=0.34 138.50 ft2 b.Sup: Attic,Ret:Sales Office,AH:Sales Office 6 86 <br /> SHi C: SHGC=0.31 <br /> b. U-�actor. Dbl,U=0.55 93.33 ftz 12•Cooling systems kBtu/hr Efficiency <br /> SH�C: SHGC=0.34 a.Central Unit 28.6 SEER:14.00 <br /> c. U-�actor: N/A ft2 <br /> b.Central Unit 17.8 SEER:14.00 <br /> SHGC: <br /> i 13.Heating systems kBtu/hr Efficiency <br /> d. U-�actor: N/A ftz a.Electric Heat Pump 28.6 HSPF:8.20 <br /> SHi C: b.Electric Heat Pump 17.6 HSPF:8.20 <br /> Area 111eighted Average Overhang Depth: 2.237 ft. <br /> Area Weighted Average SHGC: 0.322 14.Hot water systems <br /> II a.Electric Cap:50 gailons <br /> 8. Floor I ypes (2258.0 sqft.) Insulation Area EF:0.950 <br /> a.Sla -On-Grade Edge Insulation R=0.0 2258.00 ftz b. Conservation features <br /> b.N/A R= ftz None <br /> c.N/A R= ftZ 15.Credits Pstat <br /> �� Total Proposed Modified Loads: 72.03 pASS <br /> Glass/Floor Area: 0.103 Total Baseline Loads: 72.14 <br /> �� <br /> I hereby certify that the plans and specifications covered by Review of the plans and ���&p,q�,� <br /> this calc lation are in compliance with the Florida Energy specifications covered by this �, _ p <br /> Code. calculation indicates compliance �k�',,,,�''� `";�,.� � <br /> with the Florida Energy Code. 1, ��,,,�:;;;•;;;;;;;•;;,.�'``, p <br /> PREPA ED BY: � Before construction is completed 'F� „ '` � <br /> DATE: 10-18-16 this buildin g will be ins pected for � - �a�-- - � <br /> i � <br /> compliance with Section 553.908 * � <br /> I hereby certify that this building,as designed, is in compliance Florida Statutes. r� �,4 <br /> with the I torida Energy Code. �'pb�,�.�� <br /> OWNE AGENT: BUILDING OFFIC L• <br /> DATE: DATE: <br /> I <br /> - Comp iance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as <br /> certifi d factory-sealed in accordance with R403.2.2.1. <br /> -Compl ance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and an envelope leakage <br /> test rep�rt in accordance with R402.4:1.2. <br /> - Comp iance with a proposed duct leakage�n requires a Duct Leakage Test Report confirming duct leakage to outdoors, <br /> tested i� accordance with Section 803 of RESNET Standards,is not greater than 0.049 Gln for whole house. <br /> 10/18/2 16 4:14 P.M EnergyGauge�USA-FlaRes2014 Section R405.4.1 Compliant Software Page 1 of 4 <br /> I I � _ I <br />