My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
16-17938
Zephyrhills
>
Building Department
>
Permits
>
2016
>
16-17938
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/20/2017 8:57:33 AM
Creation date
7/20/2017 8:57:31 AM
Metadata
Fields
Template:
Building Department
Company Name
SILVERADO
Building Department - Doc Type
Permit
Permit #
16-17938
Building Department - Name
DUNE FL LNAD I SUB LLC C/O HAWK
Address
36063 CARRIAGE PINE CT
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
25
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
, i <br /> � <br /> ; . . . � <br /> � <br /> Fi�RM R405-2014 <br /> FL�RIDA ENERGY EFFICIENCI( CODE FOR BUILDING CONSTRUCTION <br /> Florida Department of Business and Professional Regulation - Residential Performance Method <br /> ,, <br /> Project Name: Cali Elevation D Builder Name: ,�'s s �n �� <br /> Street: ��3 �y �p���Ct Permit Office: Gi�0'F z�P�`yr���� <br /> City,State,Zip: Zephyrhills, FL,G2�' � ) Permit Num ber: �] 3 F'J <br /> Owner: -a �1/ Jurisdiction: (�/((p(/j� <br /> Desigii Location: FL,Tampa L�Z County:: Pasco(Florida Climate Zone 2) <br /> 1 New Iconstruction or existing New(From Plans) 9. Wall Types(1710.2 sqft.) Insulation Area <br /> 2. Single family or multiple family Single-family a.Concrete Block-Int Insul,Exterior R=4 1 1404.00 ftz <br /> �I b.Frame-Wood,Adjacent R=11.0 306.22 ftz <br /> 3. NumbIer of units,if multiple family 1 c.N/A R= ftz <br /> 4 Numlber af Bedrooms 4 d.N/A R= ftz <br /> 5. Is this a worst case? No 10.Ceiling Types (1828.0 sqft.) Insulation Area Z <br /> a.Under Attic(Vented) R=30.0 1828.00 ft <br /> 6. Condl itioned floor area above grade(ftz) 1828 b.N/A R= ftz <br /> Conditioned floor area below grade(ftz) 0 c.N/A R= ft <br /> z <br /> 11.Ducts R ftz <br /> 7. Windows(166.5 sqft.) Description Area a.Sup:Attic, Ret:Main,AH:Main 6 356 <br /> a. Ui�Factor: Dbl,U=0.34 126.50 ftz <br /> SHGC: SHGC=0.31 <br /> b. Ui Factor: Dbl, U=0.55 40.00 ftz 12•Cooling systems kBtu/hr Efficiency <br /> SHGC: SHGC=0.34 a.Central Unit 28.6 SEER:14.00 <br /> c. U�Factor: N/A ftz <br /> SHGC: 13.Heating systems kBtu/hr Efficiency <br /> d. Ui-Factor• N/A ftz a.Electric Heat Pump 28.6 HSPF:8.20 <br /> SHGC: <br /> Are�Weighted Average Overhang Depth: 2.722 ft. <br /> Area Weighted Average SHGC: 0.317 14.Hot water systems <br /> �� a.Electric Cap:50 gallons <br /> 8. Floor Types (1828.0 sqft.) Insulation Area EF 0.950 <br /> a.S�ab-On-Grade Edge Insulation R=0.0 1828.00 ftz b. Conservation features <br /> b.N/A R= ftz None <br /> c.NiIA R= ft2 15.Credits Pstat <br /> �I Total Proposed Modified Loads: 59J4 <br /> GlassrFloor Area. 0.091 Total Baseline Loads. 61.25 �Q�� <br />, �I <br /> I herell y certify that the plans and specifications covered by Review of the plans and ��"i�E�T,qr� <br /> this calculation are in compliance with the Florida Energy specifications covered by this � , , '� � „ , O�, <br /> Code� calculation indicates compliance � �r„��' �=�'�,�� �s+ <br /> � �„� �-=_=.,,..,N., r <br /> w i t h t h e F l o r i d a E n e r g y C o d e. ti r n r,�� •, .;.;J;�•,,.i4„ O� <br /> PREPARED BY: �-�-�� Before construction is completed c� -� <br />, D A T E: 1 6-z-7-�� t his bui l di n g wi l l b e insp ec te d fo r � I�s�' „ ,3 a <br /> �. � <br /> compliance with Section 553.908 * * <br /> I hereby certify that this building, as designed, is in compliance Florida Statutes. .t,�, �� <br /> with tli e Florida Energy Code. G�D yy�'t'�� <br /> OWNER/AGEN� BUILDING OFF IA <br /> DATiE: /��l' DATE: <br /> - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as <br /> certified factory-sealed in accordance with R403.2.2.1. <br /> -Co�pliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and an envelope leakage <br /> test eport in accordance with R402.4.1.2. <br /> - Co�iinpliance with a proposed duct leakage Gln requires a Duct Leakage Test Report confirming duct leakage to outdoors, <br /> tested in accordance with Section 803 of RESNET Standards, is not greater than 0.060 Gln for whole house. <br /> 10/ 7/2016 426 PM EnergyGaugeO USA-FlaRes2014 Section R405.4 1 Compliant Software Page 1 of 4 <br /> I <br /> � <br />
The URL can be used to link to this page
Your browser does not support the video tag.