My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
16-17938
Zephyrhills
>
Building Department
>
Permits
>
2016
>
16-17938
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/20/2017 8:57:33 AM
Creation date
7/20/2017 8:57:31 AM
Metadata
Fields
Template:
Building Department
Company Name
SILVERADO
Building Department - Doc Type
Permit
Permit #
16-17938
Building Department - Name
DUNE FL LNAD I SUB LLC C/O HAWK
Address
36063 CARRIAGE PINE CT
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
25
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
� Q��G�fis�VE'Qj Manual S Com liance Re ort �°b� �I <br /> Q �� �4 p p Date: Oct 10,2014 <br /> -� �r Entire House Bv: <br /> ,�.`�' <br /> � �� �•�:� Progressive Air Systems <br /> � <br /> Mg.� <br /> (i <br /> 5907 Dasher ct,Port Richey,FI 34668 Phone:727-847-3898 Fax:727-875-3399 License:CAC033669 <br /> II ' <br /> � • ' • 0 ' <br /> For: DR Horton/Express <br />' Lot 4 Blk 2 Silverado Ranch, Zephyrhills, FI <br /> s � • • • <br /> Deiign Conditions <br /> Oilrtdoor design DB: 91.2°F Sensible gain: 20893 Btuh Entering coil DB: 75.4°F <br /> O�tdoor design WB: 77.1 °F Latent gain: 2966 Btuh Entering coil WB: 62.7°F <br /> Indoor design DB: 75.0°F Total gain: 23859 Btuh <br /> I ��door RH: 50% Estimated airflow: 1000 cfm <br /> Ma ufacturer's Pertormance Data at Actual Design Conditions <br />' Equipment type: Split ASHP <br /> M'anufacturer: Carrier Model: CH14NA030"***A+FB4CNP030 <br /> A�ctual airflow: 1000 cfm <br /> S�ensible c acit : 23270 Btuh 111%of load <br /> �� aP Y <br />� o <br /> Latent c acit : 3914 Btuh 132/o of load <br />� aP Y <br /> TQtal capacity: 27184 Btuh 114%of load SHR: 86% <br /> �� <br /> o • • <br /> De iign Conditions <br /> O�door design DB: 40.0°F Heat loss: 21100 Btuh Entering coil DB: 69.8`F <br /> u F <br /> I door design DB: 70.0°F <br /> Ma ufacturer's Performance Data at Actual Design Conditions <br /> E,quipment type: Split ASHP <br /> IV�anufacturer: Carrier Model: CH14NA030""`�A+FB4CNP030 <br /> A�tual airflow: 1000 cfm <br /> O�put capacity: 25604 Btuh 121%of load Capacity balance: 38 °F <br /> S�pplemental heat required: 0 Btuh Economic balance: -99 °F <br /> Backup equipment type: Elec strip <br /> N�anufacturer: Model: <br /> A�tual airflow: 1000 cfm <br /> O�tput capacity: 6.6 kW 107%of load Temp. rise: 20 °F <br /> The above equipment was selected in accordance with ACCA Manual S. <br /> ��'1 wri htsoft� 2016-Oct-2716:25:35 <br /> �' � 9 Right-Suite�Universal 2013 13.0.11 RSU18520 Page 1 <br /> �� .on\Wrightsoft Files\Express homeslCali 4EBB.rup Calc=MJ8 House faces: S <br />
The URL can be used to link to this page
Your browser does not support the video tag.