Laserfiche WebLink
FORMS <br /> + TABLE 402A <br /> BUILDING COMPONENT PERFORMANCE CRITERIA' INSTALLED VALUES: <br /> U•Factor<0.65 U-Faclor= <br /> Windows(see Note 2): SHGC=0.30 <br /> %of CFA<=20% SHGC= <br /> S li hts U-Factor<0.75 %oi CFA= <br /> Doors:6cterior door U•Factor U-Factor<0.65 U-Factor= <br /> Floors: Slab-on-grade No requirement R-Value= <br /> Over unconditioned s aces see Note 3 R-13 <br /> Walfs-Ext.and Adj.(see Note 3): <br /> Frame -f - R-13 ' R-Value= <br /> Mass� (see Note 3) ' ' <br /> Interior of wall: R-7.8 R-Value= <br /> E#erior ot wali: � R-6 R-Value= <br /> Ceilings(see Notes 3&4) R=30 R-Value= Test report <br /> Rellectance 025 Reflectance= Attached7 <br /> Yes/No <br /> Air distribution system(see Note 4) <br /> Ductwork&air handling unit: <br /> Location: Test report <br /> Unconditioned space Not allowed Ariached? <br /> Conditioned space <br /> YesMo - <br /> Duct R-value R-value 2 6 R-Value= <br /> Air leakage on Qn 5 0.03 Q�_ �.- <br /> Air conditianin s stems see Note 5 SEER=13.0 SEER= <br /> Healing system <br /> Heat pump(see Note 5) Cooling: SEER=13.0 SEER= <br /> Heating: HSPF=7.7 HSPF= <br /> Gas furnace AFUE 78% AFUE_ <br /> Oii furnace AFUE 78% AFUE_ <br /> Electric resistance:Not allowed(see Note 5) <br /> Water heating system(storage type) <br /> Electric(see Note 6): 40 gai:EF=0.92 Gallons= <br /> I I 50 gal:EF=0.90 EF= <br /> Gas tired(see Note 7): 40 gal:EF=0.59 Gallons= <br /> Other(describa): 50 gal:EF=0.58 EF= <br /> ' (1)Each component present in the As Proposed home must meet or exceed each of the applicable performance criteria in orderto complywith this code using this method; <br /> othervvise Section 405 compliance must be used. <br /> (2)Windows and doors qualifying as glazed fenestration areas must complywith both the maximum U-Factorand the maximum SHGC(solar Heat Gain Coefficient)criteria <br /> and have a maximum total window area equal to or less than 20%of the conditioned floor area(CFA);othervvise Section 405 must be used for compliance. <br /> Exception: Additions of 600 square feet(56 mZ)or less may have a mauimum glass to CFA of 50 percent. <br /> (3)R-values are for insulation material only as applied in accordance with manufacturers'installation instructions.For mass walls,the"interior of wall"requirement must be <br /> met except if at least 50%of the R-6 insulation required for the"exterior ot wall"is installed exterior of,or integral to,the wall. <br /> (4)Ducts&AHU installed substantially leak free per Section 4032.2.1 Test by Class 1 BERS rater required. <br /> Exception:Ducts installed onto an existing air distritiution system as part of an addition or renovation;duct must be R-6 installed per Sec.5032.7.2. <br /> (5)For all conventional units with capacities greater than 30,000 Btu/hr For other types of equipment,see Tables 503.2.3(1-8). <br /> Exception:The prohibition on electric resistance heat does not apply to additions,renovations and new heating systems installed in existing buildings. <br /> (6)For other electric storage volumes,minimum EF=0.97-(0.00132 x volume). <br /> (7)For other natural gas storage volumes,minimum EF=0.67-(0.0019 x volume). <br /> TABLE 402B MANDATORY RE4UIREMENTS <br /> COMPONENTS SECTION REaUIREflflENT5 CHECK <br /> To be caulked,gasketed,weatherstripped or otherwise sealed.Recessed Iighting IC-rated as meeting ASTM E , <br /> Air leakage 402.4 283.Windows end doors=0.30 cfMsq.ft.Testing or visual inspection required.Fireplaces:gasketed doors& � <br /> outdoor combustion air. <br /> Ceilings/knee walls 4052.1 R-19 space permiriing. <br /> Programmable thermostat 403.1 1 Where forced-air furnace is primary system,programmable thermostat is required. <br /> Aly distribution system 403.2 Ducts in attics or on roofs insulated to R-B;other ducts R-6.Ducts tested to Q�=0.03 by a Class 1 BERS rater. <br /> Heat trap required for vertical pipe risers.Comply with efliciencies in Table 403.4.32.Provide switch or clearly <br /> Water heaters 403.4 marked circuit breaker(electric)or shutoff (gas).Circulating system pipes insulated to=R-2+accessible manual <br /> OFF switch. <br /> Spas and heated pools must have vapor-retardant covers or a liquid cover or other means proven to reduce heat <br /> Swimming pool&spas 403.9 loss except ii 70%of heat irom sita-recovered energy Off/timer switch required.Gas heaters minimum thermal <br /> efficienc =78% 82%after 4/16/13.Heat um ooI heaters minimum COP=4.0. <br /> � Sizing calculation performed&attached.Minimum efticiencies per Tables 5032.3.Equipment efficiency verification <br /> Cooling/heating equipment 403.6 required.Special occasion cooling or heating capacity requires separate system or variable capacity system. <br /> Electric heat>10kW must be divided into two or more ste es. <br /> Lighting equipment 404.1 At least 50%of permanently installed lighting 1iMures shall be high•eHicacy lamps. <br /> 2010 FLORIDA BUILDING CODE—ENERGY COfdSERVATION C.5 <br />