Laserfiche WebLink
- , FORMS <br /> TABLE 402A . <br /> BUILDING COMPONENT pERFORMANCE CRITERI ' � INSTALLED VALUES: <br /> -Factor<0.65 <br /> Windows(see Note 2): SHGC=0.30 U-Factor= <br /> %otCFA<=20% � SHGC= <br /> S li hts U-Factor<0.75 %of CFA= <br /> ' Doors:Exterior door U-Factor U-Faclor<0.65 U-Factor= <br /> Floors: Slab-on-grade � No requirement R-Value= <br /> Over uriconditioned s aces see Note 3 R-13 <br /> Walls-Exl.and Adj.(see Note 3): <br /> Frame R•13 R-Value= <br />� Mass (see Nole 3) <br /> Interior of wall: R-7.B R-Value= <br /> Exterior of wall: R-6 R-Value= <br /> Ceilings(see Notes 3&4) R=30 R•Value= Test report <br />� Feflectence 025 Reflectance= Attached7 <br /> i Yes/No <br /> Air distribution system(see Note 4) <br />� Duatwork&eir handling unit Localion: Test re ort <br /> Unconditioned space Not allowed P <br />' Condilioned space Attached7 <br /> Yes/No <br /> Duct R-value R-value z 6 R-Value= <br />, Air leakage On , Qn 5 0.03 0n_ <br />, Air conditlonin s slems see Note 5 SEER=13.0 SEER= <br /> Heating system <br />, Heal pump(see Note 5) Cooling: SEER=13.0 SEER= <br /> Heating: HSPF=7.7 HSPF= <br /> Gas fumace AFUE 78% AFUE_ <br /> Oil fumace AFUE 78% AFUE_ <br /> Eledric resistance:Not aliowed(see Note 5) , <br /> Waler heeting system(storage type) <br /> Electric(see Note 6): gal:EF=0.92 Gallons= <br /> 5 aI:EF=0.90 EF= <br /> Gas flred(see Note 7): 40 ga. - . 9 � � Gallons= <br /> Other(describe): 50 gal:EF=0.58 EF= <br />� (1)Each component present in the As Proposed home must meet or exceed each of the appliCable pertormance criteria in orderto comply with this code using this method; <br /> otherwise Section 405 compliance must be used. <br /> (2)Windows and doors qualifying as glazed fenestration areas must complywith both the maximum U-Factorand the maximum SHGC(solarHeat Gain Coefficient)criteria <br /> and have a maximum total window area equal to or less than 20%of the conditioned floor area(CFA);othenvise Section 405 must be used for compliance. <br /> Exception: Additions of 600 square feet(56 m2)or less may have a maximum glass to CFA of 50 percent. <br /> (3)R-values are for insulation material only as apptied in accordance with manufacturers'instaliation insVuctions.For mass walls,the"interior of walP'requirement must be <br /> met except if at least 50%of the R-6 insulation required for the°exterior of wall"is installed exterior of,or.integral to,the wall. <br /> (4)Ducts&AHU installed substantially leak free per Section 403.2.2.1.Test by Class 1 BERS rater required. <br /> Exception:Ducts installed onto an existing air distribution system as pari of an addition or renovation;duct must be R-6 installed per Sec.5032.72. <br /> (5)For all conventional units with capacities greater than 30,000 Btu/hr. For other types of equipment,see Tables 503.2.3(1-8). <br /> Exception:The prohibition on electric resistance heat does not apply to additions,renovations and new heating systems installed in existing buildings. <br /> (6)For other eleciric storage volumes,minimum EF=0.97-(0.00132 x volume). <br /> (7)For other natural gas storage volumes,minimum EF=0.67-(0.0019 x volume). <br /> TABLE 402B MANDATORY REOUIREMENTS <br /> COMPONENTS " SECTION RE�UIREMENTS CHECK <br /> - To be caulked,gaskeled,weatherstripped or otherwise sealed.Recessed lighting IGrated as meeling ASTM E � <br /> Air leakage 402.4 283.Windows and doors=0.30 c(m/sq.tt.Testing or visual Inspection required.Freplaces:gasketed doors& <br /> ouldoor crombustion air. <br />' Ceilings/knee walls 405.2.1 R-19 space permitfing. <br /> Programmable thermostat 403.1.1 Where forced-air}umace(s primary system,programmabla thermostet is required. <br /> Air dstribution system 4032 Ducts in attics or on roofs insulated to R-8;other ducts R-6.Ducts tested to�,=0.03 by a Class 1 BERS rater. <br /> Heat trap required tor vertical pipe risers.Comply with efficiencies in Table 403.4.3.2.Provide switch or cleaAy <br /> Water heaters 403.4 marked circuit breaker(eiectric)or shutoft (gas).Circulaling system pipes insula[ed to=R-2+accessible manual <br /> OFF switch. <br /> Spas and heated pools musl have vapor-retardant covers or a liquid cover or other means proven to reduce heat ' <br /> Swimming pool 8 spas 403.9 loss except if 70%of heat fram site-recovered energy.Off/timer switch required.Gas heaters minimum thermal <br /> efficien =78% 82%aRer M16/13.Hea1 um ooI heaters minimum COP=4.0. <br /> Sizing calculation peAortned 8 altached.Minimum efficiencies par Tables 503.2.3.Equipmenl efficiency verification _ <br /> Coolinglheating equipment 403.6 requlred.Spaclai occasion cooling or heating capacity requires separate system or variable capacity syslem. <br /> Eleclric heat>10kW must be divided into two or more sta es. <br /> Lighling equfpment 404.1 At least 50%of pertnanently installed lighting fixtures shall he high-efficacy lamps. <br /> 2010 FLORIDA BUILDING CODE—ENERGY CONSERVATION ' C.5 <br />� — — <br />