Laserfiche WebLink
r-'^a y.."...� <br /> 1 �`i.�,' � . <br /> � ��`�yi <br /> -- - -- -�`�����f�ii°�ii`��ERD ---- <br /> APPENDIX 1:ATTACHMENT REQUIREMEN75 FOR WIND UPLIFT RESISTANCE <br /> Table Deck Application Type Descriptian Page <br /> 1A Wood New or Reroof(Tear-Off) A-2 Mech.Attached Anchor Sheet,Bonded Insulation,Bonded Roof Cover 5 <br /> 18 Wood New,Reroof(Tear-Offl or Recover B-1 Mech.Attached Base Insulation,Bonded Top Insulation,Bonded Roof Cover 5 <br /> 1C Wood New,Reroof(Tear-Of�or Recover C Mech.Attached Insulation,Bonded Roof Cover 5-6 <br /> 1D Wood New,Reroof(Tear-Of�or Recover D Insulated,Mech.Attached Base Sheet,Bonded Roof Cover 7 <br /> lE-1 Wood New or Reroof(Tear-Of� E Non-Insulated,Mech.Attached Base Sheet,Bonded Roof Cover 7-8 <br /> lE-2 Wood New,Reroof(Tear-Of�or Recover E Non-Insulated,Mech.Attached Base Sheet,8onded Roof Cover 8 <br /> 2A-1 Steel or Conc, New,Reroof(Tear-Offl or Recover B-1 Mech.Attached Base Insulation,Bonded Top Insulation,Bonded Roof Cover 9-14 <br /> 2A-2 Steel or Conc. New,Reroof(Tear-Offl or Recover B-2 Mech.Attached Thermal Barrier,Bonded Temp Roof,Bonded Insulation,Bonded Roof Cover 15-16 <br /> 2B Steel or Conc. New,Reroof(Tear-Offl or Recover C Mech.Attached Insulation,Bonded Roof Cover 17-28 <br /> 2C Steel or Conc. New,Reroof(Tear-Offl or Recover D Insulated,Mech.Attached Base Sheet,Bonded Roof Cover 29-30 <br /> 3A Concrete New or Reroof(Tear-Of� A-1 Bonded Insulation,8onded Roof Cover 31-36 <br /> 30 Concrete New or Reroof(Tear-Offl A3 Bonded Temp Roof,Bonded Insulation,Bonded Roof Cover 37-41 <br /> 3C Concrete New or Reroof(Tear-Off) F Non-insulated,Bonded Roof Cover 41 <br /> 4A LWIC New or Reroof(Tear-Of� A-1 Bonded Insulation,Bonded Roof Cover 42-50 <br /> 4B LWIC New or Reroof(Tear-Off) A-2 Mech.Attached Anchor Sheet,Bonded Insulation,Bonded Roof Cover 51 <br /> 4C-1 LWIC New or Reroof(Tear-Of� E Non-Insulated,Mech.Attached Base Sheet,Bonded Roof Cover 52-54 <br /> 4C-2 LWIC New or Reroof(Tear-Of� E Non-Insulated,Mech.Attached Base Sheet,Bonded Roof Cover 55 <br /> SA CWF New or Reroof(Tear-Of� A-1 Bonded Insulation,Bonded Roof Cover 56 <br /> SB CWF New,Reroof(Tear-Of�or Recover A-2 Mech.Attached Anchor Sheet,Bonded Insulatlon,Bonded Roof Cover 56 <br /> SC CWF New,Reroof(Tear-Of�or Recover B-1 Mech.Attached Base Insulation,Bonded Top Insulation,Bonded Roof Cover 56 <br /> SD CWF New,Reroof(Tear-Offl or Recover C Mech.Attached Insulation,Bonded Roof Cover 57 <br /> SE CWF New,Reroof(Tear-Off)or Recover D Insulated,Mech.Attached Base Sheet,Bonded Roof Cover 57 <br /> SF CWF New,Reroof(Tear-Offl or Recover E Non-Insulated,Mech.Attached Base Sheet,Bonded Roof Cover 57 <br /> 6A Gypsum Reroof(Tear-Offl A-1 Bonded Insulation,Bonded Roof Cover 58-59 <br /> 6B Gypsum Reroof(Tear-Offl A-2 Mech.Attached Anchor Sheet,Bonded Insulation,Bonded Roof Cover 60 <br /> 6C Gypsum Reroof(Tear-Offl B-1 Mech.Attached Base Insulation,Bonded Top Insulation,Bonded Roof Cover 60 <br /> 6D Gypsum Reroof(Tear-Offl C Mech.Attached Insulation,Bonded Roof Cover 61 <br /> 6E Gypsum Reroof(Tear-Offl D Insulated,Mech.Attached Base Sheet,Bonded Roof Cover 61 <br /> 6F Gypsum Reroof(Tear-Of� E Non-Insulated,Mech.Attached Base Sheet,Bonded Roof Cover 61 <br /> 7A Various Recover A-1 Bonded Insulation,Bonded Roof Cover 62-67 <br />' Exterior Research and Design,LLC.d/b/a Trinity�ERD Evaluation Report F8970.01.08-2-R31 for FL984-R11 <br /> Certificate of Authorization#9503 Revision 11:04/08/2015 <br /> Prepared by Robert Nieminen,PE-59166 Appendix 1,Page 1 of 67 <br />�� - <br />