My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
17-16912
Zephyrhills
>
Building Department
>
Permits
>
2017
>
17-16912
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/31/2017 12:28:58 PM
Creation date
7/31/2017 12:28:56 PM
Metadata
Fields
Template:
Building Department
Company Name
DRIFTWOOD
Building Department - Doc Type
Permit
Permit #
107-16912
Building Department - Name
RYMAN CONSTRUCTION
Address
6744 BASSWOOD CIR LOT 40
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
25
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
t . , ; <br /> . ,. I i <br /> • � Job: Driftwood B Plex <br /> ..� � �i������ Proj�ct Summary Date: Jan 25,Zo,s <br /> Unit 4 By: DJM ' <br />, �� - <br /> ' . - . • <br /> For: Driftwood of Zephyrhills <br /> Zephyrhills, FL <br /> Notes: <br /> � - • • • <br /> Weather: Tampa, FL, US <br /> Winter Design Conditions Summer Design Conditions <br /> Outside db 41 °F Outside db 91 °F <br /> Inside db 70 °F Inside db 75 °F <br /> Design TD 29 °F Design TD 16 °F <br /> Daily range L <br /> Relative humidity 50 % <br /> Moisture difference 56 gr/lb <br /> Heating Sumenary Sensible Cooling Equipment Load Sizing ! <br /> Structure 6480 Btuh Structure 7749 Btuh <br /> �Ducts 2537 Btuh Ducts 3519 Btuh <br /> Central vent(0 cfm) 0 Btuh Central vent(0 cfm) 0 Btuh <br /> Humidification 0 Btuh Blower 0 Btuh <br /> Piping 0 Btuh . <br /> �Equipment load 9017 Btuh Use manufacturer's data n <br /> Rate/swing multiplier 0.96 <br /> Infiltration Equipment sensible load 10862 Btuh � <br /> Method Simplified Latent Cooling �quipment Load Sizing � <br /> ;Construction quality Average <br /> Fireplaces 0 Structure 1506 Btuh I <br /> Ducts 870 Btuh � <br /> Heating Cooling Central vent(0 cfm) 0 Btuh <br /> Prea(ftz) 1198 1198 Equipment latent load 2376 Btuh <br /> IVolume(ft') 10449 10449 <br /> Air changes/hour 0.20 0.11 Equipment total load 13238 Btuh <br />' �Equiv.AVF(cfm) 35 19 Req.total capacity at 0.70 SHR 1.3 ton <br /> Heating Equipment Summary Cooling Equipment Summary <br />� Make Carrier Make Carrier <br /> �frade CARRIER Trade CARRIER <br /> Model 25HBC318(A,W)`"30 Cond 25HBC318(A,W)*"30 <br /> �AHRI ref 5950184 Coil FB4CNP018 <br /> AHRI ref 5950184 � <br /> Efficiency 8.2 HSPF Efficiency 11.5 EER, 14 SEER ; <br />' �Heating input Sensible cooling 12180 Btuh <br /> Heating output 17400 Btuh @ 47°F Latent cooling 5220 Btuh <br /> I Total coolin 17400 Btuh � <br /> Tem erature rise 27 °F 9 ' <br /> P <br /> Actual air flow 580 cfm Actual air flow 580 cfm � <br /> �4ir flow factor 0.064 cfm/Btuh Air flow factor 0.051 cfm/Btuh � <br /> Static pressure 0.53 in H20 Static pressure 0.53 in H20 <br /> �Space thermostat Load sensible heat ratio 0.83 <br /> Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. <br /> 2016-Jan-26 08:15:44 <br /> ,��"'`'+-"�--' "� ��'�'�h���� Right-Suite�Universa1201515.0.21 RSU11033 Page4 <br /> �TM�' .le Drive\DocumentslSonny's\Driflwood 6 plex.rup Calc=MJ8 Front Door faces: E <br />
The URL can be used to link to this page
Your browser does not support the video tag.