Laserfiche WebLink
� � . <br /> ` •FORM 405-2014 <br /> �FL��IDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION <br /> Flori�da Department of Business and Professional Regulation - Residential PerFormance Method <br /> Project Na e: 1941 sf WHC Silverado ranch Builder Name: Lennar Homes <br /> street: 6402 Silverado Ranch Boulevard Perm�t o�ce: City of Zephyrhills <br /> City,State Zip: Z-Hills,FL, Permit Number �8d j� <br /> Owner: Lennar homes Jurisdiction. (� �(�pC� <br /> Design Lo� tion: FL,Tampa <br /> 1. New con truction or existing Addition 9. Wall Types(354.7 sqft.) Insulation Area <br /> 2. Single fa ily or multiple family Single-family a.Concrete Block-Int Insul, Exterior R=4.1 242.67 ftz <br /> b.Frame-Wood,Exterior R=11.0 112.00 ftz <br /> 3. Number f units, if multiple family 1 c.N/A : <br /> R= ft <br /> 4 Number f Bedrooms(Bedrms In Addition) 0(0) d.N/A R= ft� <br /> 5. Is this a orst case? No 10.Ceiling Types (416.0 sqft.) Insulation Area <br /> a. Under Attic(Vented) R=30.0 416.00 ft2 <br /> 6. Conditio ed floor area above grade(ftz) 416 b. N/A R= ft2 <br /> Conditio�ed floor area below grade(ftz) 0 c. N/A R= ft2 <br /> 11.Ducts R ft2 <br /> 7. Windows(32.7 sqft.) Description Area a.Sup:Attic, Ret:Attic,AH:Main 6 113 <br /> a. U-Fac or: Dbl, U=0.27 20.67 ftZ . <br /> SHG � SHGC=0.30 <br /> b. U-Fac�or: Dbl,U=0.54 12.00 ft� �2•Cooling systems , kBtu/hr Efficiency <br /> SHG : SHGC=0.31 a.Central Unit 18.0 SEER:16.00 <br /> c. U-Fac or• N/A ftz <br /> SHG : 13. Heating systems kBtu/hr Efficiency <br /> d. U-Fac or N/A ftZ a.Electric Heat Pump 17.5 HSPF:8.50 <br /> SHG : <br /> Area Wei hted Average Overhang Depth: 1.000 ft. <br /> Area Wei hted Average SHGC� 0.304 14.Hot water systems-None required <br /> a• Cap: N/A <br /> 8. Floor Ty es (416.0 sqft.) Insulation Area EF:-0.031 <br /> a.Slab-On-Grade Edge Insulation R=0.0 416.00 ftZ b. Conservation features <br /> b.N/A R= ft� � <br /> c. N/A R= �2 15.Credits Pstat <br /> ' Total Proposed Modified Loads: 10.62 pASS <br /> Glass/Flo r Area: 0.079 <br /> Total Baseline Loads: 11.99 <br /> I hereby c rtify that the plans and specifications covered by Review of the plans and Q�`���TRT„� ` <br /> this calcul tion are in compliance with the Florida Energy specifications covered by this y . =-4 ; p <br /> Code. I calculation indicates compliance �'�'�if,;`'`': -'=�:;,�� � <br /> �ave W[{�/�Yl With the Florida Energy Code. � � H#t�-�,��ai -.,.:r�;;��"�;,�� ' <br /> �.,, � <br /> PREPAR D BY: � Before construction is completed w � `� `` .-.. <br /> DATE: this building will be inspected for �.�""`;1}�." :"�" • ~ �; <br /> compliance with Section 553.908 * ' � , : ;� <br /> I hereby c rtify that this building,as designed, is i compliance Florida Statutes. ' �.=.. <br /> with the FI rida Energy Code. ��'O,r�.�,���� <br /> OWNER/ GENT: BUILDING OFFIC L: �, <br /> DATE: � Y DATE: <br /> - Complia�nce requires certification by the air handler unit manufacturer that the air handler encl ure qualifies as <br /> certifiedl factory-sealed in accordance with R403.2.2.1. <br /> -Complia ce requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and an envelope leakage <br /> test repo in accordance with R402.4.1.2. <br /> - Compli nce with a proposed duct leakage Qn requires a Duct Leakage Test Report confirming duct leakage to outdoors, <br /> tested in ccordance with Section 803 of RESNET Standards, is not greater than 0.030 Qn for whole house. <br /> 9/28/201 7:27 AM EnergyGauge�USA-FlaRes2014 Section R405.4.1 Compliant SoHware Page 1 of 4 <br />