Laserfiche WebLink
.. _ �:, .. E . <br /> "'" PERMIT°WORKSHEET e <br /> , pag 2 of 2 <br /> � <br /> PERMIT NUMBER .� < <br /> � Slte Pre aredon <br /> POCK P O TER TES XiS��.�'a <br /> Debrts and organlc mateHal removed ('L,�+,��� �U <br /> 7he pocket penetrnmeter.tests ere rounded down fo =----_psf Water drainage;Nature! Savale Pad ��her �� <br /> or check here to deciare 7000 Ib.soll W►thout te"stlng. • <br /> FosEoning multi w da un fs. <br /> X'` `,. � � � X � F7oor. Type F.astener. LQ. S Length: �� Spac(ng: �� <br /> Walls: Type Fasfener: length: Spacing: �� <br /> pOCKET pENE7ROME7ER TESTINO METHOD Roof. 7ype Fastener. Length: Spar.in�: 1 �� <br /> For used homes a 30 gauge,8"wlde,galvanlxed Metal atrip <br /> 1. Test Ehe perlmeker of the home at 6 locations. will 6e centered over the peak of fhe roof and fastened�With ga(v, <br /> roofing nails at 2"on cenfer on both sides of the centerline, <br /> 2. Take the reading at the depth of the foofer. <br /> ' -----� Qeskat(vm�thorpwoflnaroa+trom�ntl ' <br /> ' 3. Using 600 Ib.inorements,take the lowesf • <br /> reading ancl round down to that Incremenk � I uhdersfar,d a properiy installed gasket(s a requlrem�nt of all new and used <br /> , homes and that cohdensation,tnqld,meldsw at�i bucfded marriage walfs are <br /> a result of a pooriy Instal[ed�or no gasket befng inst211ed. I uhderstaru!a sfrip <br /> X�_ X _ X�_ of teps wil(not serve as a gasket. <br /> InstaOer's Initlals''"'� <br /> • TO U P OB 5 <br /> ' 7ype gasket�j ' Instailed: ' <br /> The results of the torque probe test is tnch pounds or check Pg. � Be(ween Floors Yes k <br /> here if you are dadaring 5'anchars Wlthout festfhg . A test Batween.Walfs Yes_ X <br /> shaw(ng 27b Inch pounds or less wlll requin t�'foot anchors. 8ottom of ridgebeam Yes�^ <br /> Note: A:state eppmved lateral arm sysfem ts being uaed and 4 ft. <br /> anchors at�a allowed at the sidewal(locations. I understand 6 ft " Weetherprooflng - <br /> anchors are requtred at aIl cer�tedine tle polnts where fhe torque tesf <br /> � "' reading ls 276 or iess and where the mobile home manufacturer may The bottomboard wlll be repalred and/or taped. Yes .�C pg, ' <br /> - requires anchors with 4000 Ib hoiding capacity. 5fcltng on unita is installed to manufacfuror's spectflca ions,' es,.,�_ - <br /> �" Installer's tnlflals �Ueplace chtM�e}�Installe�i$o as not to aitow inhus(on of raln water, Yes <br /> AL�7'ESTS MUST BE PERFOR �D BY A LICENSED INSTALL�R Mtscellan�oua <br /> Installer Name (,� ('4 (,��,�_``}�����' • Skirting to be.insta0eci. Yes No <br /> � ' . Dryer vent instailed outstde of ing. Y`�r►/A• <br /> D�te 7esfed Range downflovii venf insfalled outalde of skitting.—Yes_�____N/A <br /> �— � Drein lines sup�sorted at°4 foot ihtervals. Yes�_ . <br /> Ele�trical crossovers protected. Yes,�_ <br /> Qthar; � <br /> � Ele�t�lesd <br /> . -�—: <br /> , Connect electrlcal conducfors be�in►een muiti-wids ur�it�,but noE to the main power — <br /> source. This lncludss the bonding wire batween mult wtde units, Pg. Instatler verlfles atl information-g[ven�wtth this permlt worksneet <br /> lumb ng is accurate and true based on� <br /> _ Connect all sewer dralns to an existing sewer tap ar septtc tank Pg.- manuf8cturer's installation lnstructlons and or 12u1e 15C•?&2 <br /> Connect ati potable wafer supply plping to an exis�ng water meter.waEer tap,or other Installer Signatur�.�--� ,J �� Date_I��,����i <br /> , Inilependent water supply a�rstems. Pg. <br />