My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
17-18025
Zephyrhills
>
Building Department
>
Permits
>
2017
>
17-18025
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/1/2017 10:42:28 AM
Creation date
8/1/2017 10:42:27 AM
Metadata
Fields
Template:
Building Department
Company Name
DRIFTWOOD
Building Department - Doc Type
Permit
Permit #
17-18025
Building Department - Name
KAHRL,TOMMY
Address
38351 IRONWOOD PL
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
15
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Si <br /> � J� <br /> - - - " - - - - - - —A1AX:BUMq4=WIDT - ---- -- - ----- - -_ - - - - - <br /> MAX.BUCK WIDTH SEE TABLE 1 <br /> SEETABLE 1 28' �+-- MAX.BUCK WIDTH -..{ �� <br /> MAX. �-� p. ,C � I SEE TABLE 1 I � r MAX. ' • <br /> 2B' 1 Y <br /> �r B,SEE �• D,SEE I 4'MA%.O.C. <br /> B,SEE <br /> MAX.�� �-C' � _ SHEET 3 SHEET 4�-1 � � I <br /> SHEET 3 A,SEE <br /> A,SEE SHEET 3 �� S EET 4 � <br /> SHEET 3 ` ��' / <br /> / 17.88T MAX.O.C. / T � / � <br /> � �_ I 17.8 T6� MAX.O.C. � I / � <br /> I � MAX.BUCK I � �- 4'MAX. � MAX.BUCK <br /> � HEIGHTSEE O.C. � HEIGHTSEE j <br /> �- MAX.BUCK <br /> 4 10'MAX.O.C. T��' HEIGHT SEE X 4 TABLE 1 � <br /> X o T��, - � <br /> _ /- � � � � ! <br /> I 13.773'MAX.O.C. X � - 10'MAX.O.F. � . <br /> � A -J—L C <br /> � / q 13.773'MAX.O.C. i <br /> � <br /> . 8-112•MAX. / B-tl2'MA)C. D 2'MAX. -�{ r� ! <br /> B NO ANCHORS AT SILL � B NO ANCHORS AT SILL I <br /> � I <br /> ELEVATION FOR 7YP.FLANGE FRAME, ELEVATION FOR TYP.FIN OR J-CHANNEL FRAME, ! <br /> ELEVATION FOR TYP.EQUAL LEG FRAME, EQUAL-LITE CONFIGURATION ` <br /> EQUAL-LITE CONFIGURATION PROVIEW/ORIEL CONFIGURATION (SIMIUIR ANCHOR DIMENSIONS FOR OTHER CONFIGURATIONS) <br /> ICOTTAGE SIMILAR) I <br /> 1 <br /> TABLE L• ( <br /> GENERAL NOTES:SERIES 5400 NON-IMPACT RESISTANT, H►indow Buck Size Reinf. Desi9n Pressure Certification !i <br /> VINYL SINGLE HUNG WINDOW Width Height �Onflguratlon �eVe� {+)psf (_)ps{ (CAR)Number f <br /> r <br /> 1)THIS PRODUCT HAS BEEN DESIGNED&TESTED TO COMPLY WITH THE �p �� Equal-lite R4 bO.O �O.O 190-1 OZZ <br /> RE�UIREMENTS OF THE FLORIDA BUILDING CODE 36" 6Y Equal-lite SHAPES MAY BE USED BY <br /> INSCRIBING THE SFiAPE IN s <br /> 2)ALL WOOD 6UCKS LESS TFiAN 1-1/2'THICK ARE TO BE CONSIOERED 1X 36" 62" Std.ProView R4 5�.0 50.0 1�-�02� A BLOCK AND OBTAINING ! <br /> INSTALLATIONS.1X WOOD BUCKS ARE OPTIONAL IF UNIT IS INSTALLED DIRECTLY � 67-9/�6" CIIS�ORf S9SI1 DESIGN PRESSURES FOR j <br /> TO SUBSTRATE.WOOD BUCKS DEPICTED AS 2X ARE 1-1/2'THICK OR GREATER. THAT BLOCK SIZE FROM � <br /> 1X AND?X BUCKS(WHEN USED)SHALL BE DESIGNED TO PROPERLY TRANSFER SZ-'I/8" 84° EqUBI-IItB THE TABLE ON THIS SHEET. <br /> LOADS TO THE STRUCTURE.WOOD BUCK DESIGN AND INSTALLATION IS THE � - � � <br /> RESPONSIBILITV OF THE ENGINEER,(EOR)OR ARCHITECT OF RECORD,�AOR). 52-1/8" B4," StC.PIOVICW R'I SO.O .SO.O 190.1021 <br /> 3)ANCHOR EMBEDMENT TO BASE MATERIAL SHALL BE BEYOND WALL DRESSING 52-1�8" 91-13l16" Custom Sash ' <br /> OR STUCCO.USE ANCHORS OF SUFFICIENT EMBEDMENT INSTALLA770N 52-118� &I" Equal-Ike $ <br /> ANCHORS SHOULD BE SEALED.OVERALL SEALING/FLASHING STRAFEGY FOR <br /> WATER RESISTANCE OF INSTALLATION SHALL BE DONE BYOTHERS AND IS b2-�/8" B4" Std.ProView RZ 6S.O �O.O 190-1026 � <br /> ' BEYOND THE SCOPE OF THESE INSTRUCTIONS. 5Q-�/8" 91-�3/16" G19tOR1 SBSh �t I i i(f; ' <br /> 4)MAX.1/4'SHIMSAREREQUIREDATEACHANCHORLOCATIONWHERETHE �`��,a „ ���%, ! <br /> PRODUCT IS NOT FLUSH 70 THE SUBSTRATE.USE SHIMS CAPABLE OF '��,O`;� ���' S'��!;.���� i <br /> TRANSFERRING APPLIED LOADS,WOOD Bl1CK5,BY OTHERS,MUST BE ' �'�C-�'�� �"•'%� ` <br /> SUFFICIENTLY ANCHORED TO RESIST LOADS IMPOSED ON THEM BY THE WINDOW. � ��' -n.% i <br /> ... ; <br /> � VINYL SH WINDOW FPA(NON-IMPACT) " 12/13/14 . e �•'�'�''"''' <br /> 5)THE ANCHORAGE ME7HODS SHOWN HAVE BEEN DESIGNED TO RESIST THE o ' ' ! <br /> WINDLOADS CORRESPONDING TO THE RE�UIRED DESIGN PRESSURE.THE Gl � <br /> 33-113%STRESS INCREASE HAS NOT BEEN USED IN THE DESIGN OF1}iIS o GENERAL NOTES 8 ELEVATIONS om J ROSOWSKI .':, �� �� J:. i <br /> PRODUCi.THE 1.8 LOAD DURATION FACTOR WAS USED FOR THE EVALUATION OF � ,. _ ��;���- � <br /> ANCHORS INTO WO00.ANCHORS THAT COME INTO CONTACT WITH OTHER � ��-` �•'��' _ ,�}, '�;` � <br /> DfS51MILAR MATERIALS SHALL MEET THE REQUIREMENTS OF THE FLORIDA CERT OF AUTH.#29286 � � � <br /> BUILDING CODE FOR CORROSION RESISTANCE. ; �G �`��i�j f•�.r;� �`�•� � <br /> 1070 TECHNOLOGY DRIVE <br /> N.VENICE,FL34275 p p$ ����"'"'`� ; <br /> 0.LYNN b1LLLER P.E. <br /> (941)-480-160D � SH-5400 ,� NTS � 1 OF 4 o z FPA-5400.0 �z P E���� ; <br /> � <br />
The URL can be used to link to this page
Your browser does not support the video tag.