Laserfiche WebLink
� �, . � <br /> FORM R405-2014 <br /> FL��Oi�IDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION <br /> �lorida Department of Business and Professional Regulatit�n - Residential Performance Method <br /> Projelct Name: Aria Elevation D Builder Name: DRH Express Homes <br /> ' ��IDS"�r►4 ` G`�rr-�z�����/s <br /> Street: ��2.�� Permit Office: <br /> City,�tate,Zip: yrhills,FL,� L'� � / Permit Number: ` �f <br /> Owner: �� Jurisdiction: (p[1�GOd <br /> Design Location: FL,Tampa . ��/' County:: Pasco(Florida Climate Zone 2) <br /> I <br /> 1. Nev�1I construction or existing New(From Plans) 9. Wall Types(1658.2 sqft.) Insulation Area <br /> 2. Single family or multiple family Single-family a.Concrete Block-Int Insul,Exterior R=4.1 1372.20 ftz <br /> b.Frame-Wood,Adjacent R=11.0 286.00 ftz <br /> 3. Number of units,if multiple family 1 c.N/A R= ftz <br /> 4. Number of Bedrooms 3 d.N/A R= ftz <br /> f 10.Ceiling Types (1672.0 sqft.) Insulation Area <br /> 5. Is thils a worst case? No a.Under Attic(Vented) R=30.0 1672.00 ftz <br /> 6. Conditioned floor area above grade(ftz) 1672 b.N/A R= ft2 <br /> Conditioned floor area below grade(ftz) 0 c.N/A R= ftz <br /> I 11. Ducts R ftz <br /> 7. Windows(182.0 sqft.) Description Area a.Sup:Attic,Ret:Main,AH:Main 6 392 <br /> a. U�Factor: Dbl,U=0.34 142.00 ftz <br /> SHGC: SHGC=0.31 <br /> b. U IFactor• Dbl,U=0.55 40.00 ftz 12.Cooling systerris kBtu/hr Efficiency <br /> SHGC: SHGC=0.34 a.Central Unit 28.6 SEER:14.00 <br /> c. U-�actor: N/A ft2 <br /> SHGC: 13. Heating systems kBtu/hr Efficiency <br /> d. U-Factor: N/A ftz a.Electric Heat Pump 28.6 HSPF:8.20 <br /> SFiGC: <br /> Area YVeighted Average Overhang Depth: 4.985 ft. � <br /> Area Weighted Average SHGC: 0.317 14.Hot water systems <br /> � a.Electric Cap:50 gallons <br /> 8. Floor�Types (1672.0 sqft.) Insulation Area EF:0.950 � <br /> a.Slab-On-Grade Edge Insulation R=0.0 1672.00 ftz b. Conservation features _ <br /> b.N/A � R= ftz None � <br /> c.N/A . R= ft2 15.Credits Pstat � <br /> I <br /> � Total Proposed Modified Loads: 48.91 <br /> Glass/�loor Area: 0.109 Total Baseline Loads: 57.14 PASS <br /> I hereb�certify that the plans and specifications covered by Review of the plans and ��T��TA� <br /> this calculation are in compliance with the Florida Energy specifications covered by this ,y ,� _�,` O�, <br /> Code. calculation indicates compliance �i`�„��o'':� __ �,����� <br /> I with the Florida Ener Code. N r1ru.�K'�;:_=_�-�°��� O <br /> 9Y r. ,;..,» ti, <br /> :,,�.-.... <br /> PREP �RED BY: �'�-�� Before construction is completed � <br /> DATE: I II-7-I6 this building will be inspected for � ��;" ,� <br /> compliance with Section 553.908 * ° � <br /> I hereby�certify that this building, as designed,is in compliance Florida Statutes. � �� <br /> with the lorida Energy Code. �C // �QD y�`�� <br /> OWNE AGE . BUILDING OFFICIAL: � <br /> DATE: i �T /_ DATE: - <br /> - Comp iance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as I <br /> certifi�d factory-sealed in accordance with R403.2.2.1. i <br /> -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and an envelope�leakage , <br /> test rep rt in accordance with R402.4.1.2. <br /> 11/7/2016 10:41 AM EnergyGaugeO USA-FlaRes2014 Section R405.4.1 Compliant Software Page 1 of 4 ' <br /> / � <br />