Laserfiche WebLink
: itr , <br /> FORM R405-2014 <br /> I <br /> FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION <br /> � <br /> F�orida Department of Business and Professional Regulation - Residential Performance Method <br /> ProjecfiI Name: Cali Elevation � Builder Name: DRH Express Homes <br /> Street:l � +S � �T1 Q � ►�e�� Permit Office: �� �Q�i,(/�///�� <br /> City S�ate,Zip: Zephyrhills, FL,��' '/ Permit Number: / � r � <br /> Owner �V/ Jurisdiction: �a/l�-� <br /> Design�Location: FL,Tampa /�// County:: Pasco(Florida Climate Zone 2) <br /> t <br /> 1. New onstruction or existing New(From Plans) 9. Wall Types(1710.2 sqft.) Insulation Area <br /> 2. Singl family or multiple family Single-family a.Concrete Block-Int Insul, Exterior R=4 1 1404.00 ftz <br /> b.Frame-Wood,Adjacent R=11.0 306.22 ftz <br /> 3. Number of units,if multiple family 1 c.N/A R= ft2 <br /> 4. Numb�er of Bedrooms 4 d.N/A R= ft2 <br /> 10.Ceiling Types (1828.0 sqft.) Insulation Area <br /> 5. Is thi a worst case? No a.Under Attic(Vented) R=30.0 1828.00 ft2 <br /> 6. Conditioned floor area above grade(ft2) 1828 b.N/A R= ft2 <br /> z <br /> Conditioned floor area below grade(ftz) 0 c.N/A R= ft <br /> 11.Ducts R ftz <br /> 7 Windows(166.5 sqft.) Description Area a.Sup:Attic,Ret:Main,AH:Main 6 356 <br /> a. U-Factor: Dbl,U=0.34 126.50 ft2 <br /> SHGC: SHGC=0.31 <br /> b. U-Factor: Dbl,U=0.55 40.00 ftz 12•Cooling systems kBtu/hr Efficiency <br /> SHiGC: SHGC=0.34 a.Central Unit 28.6 SEER:14.00 <br /> c. U-Factor• N/A ftz <br /> SFIHGC: 13.Heating systems kBtu/hr Efficiency <br /> d. U-Factor: N/A ftz a.Electric Heat Pump 28.6 HSPF:8.20 <br /> SHGC: <br /> Area�eighted Average Overhang Depth: 2.722 ft. <br /> Area Weighted Average SHGC: 0.317 14.Hot water systems <br /> 8. Floor i ypes (1828.0 sqft.) Insulation Area a.Electric Cap:50 gallons <br /> EF:0.950 <br /> a.Slab-On-Grade Edge Insulation R=0.0 1828.00 ftz b. Conservation features <br /> b.N/'�� R= ftz None <br /> c.N/AI R= ftz 15.Credits Pstat <br /> � Total Proposed Modified Loads: 60.72 <br /> Glass/Floor Area: 0.091 Total Baseline Loads: 61.25 PASS <br /> I hereb�certify that the plans and specifications covered by Review of the plans and ���HE S�g�� <br /> this calculation are in compliance with the Florida Energy specifications covered by this � ,� , ' �� p� <br /> Code. calculation indicates compliance � �i,,�''�`,, `;=;:�,`�`„�, <br /> with the Florida Energy Code. N rnur�'�-,. -;:r,;w��;.,, „ O <br /> PREP RED BY: L'N4_�� Before construction is completed c� ' � <br /> � _.�...�;� CJ <br /> DATE: II-4-I6 this building will be inspected for � tya=�' y <br /> compliance with Section 553.908 * :'�' fl * <br /> I hereb certify that this building,as designed, is in compliance Florida Statutes. �t �y� <br /> with the Florida Energy Code. L�/l �D WE'� <br /> OWNE AGENT• BUILDING OFFICIAL: '�� <br /> DATE: �� �� DATE: -� ` <br /> - Comp�liance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as <br /> certified factory-sealed in accordance with R403.2.2.1. <br /> -Comp�iance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and an envelope leakage <br /> test report in accordance with R402.4.1.2. <br /> - Com�liance with a proposed duct leakage�n requires a Duct Leakage Test Report confirming duct leakage to outdoors, <br /> tested i accordance with Section 803 of RESNET Standards, is not greater than 0.060 Qn for whole house. <br /> 1 1/4/201 6 4:30 PM EnergyGaugeO USA-FlaRes2014 Section R405.4.1 Compliant Software Page 1 of 4 <br />