My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
17-18054
Zephyrhills
>
Building Department
>
Permits
>
2017
>
17-18054
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/1/2017 11:05:46 AM
Creation date
8/1/2017 11:05:45 AM
Metadata
Fields
Template:
Building Department
Company Name
SILVERADO
Building Department - Doc Type
Permit
Permit #
17-18054
Building Department - Name
DUNE FL LAND I SUB C/O HAWK MANA
Address
36084 CARRIAGE PINE CT
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
25
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
FOF�M R405-2014 <br /> FL�RIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION <br /> Florida Department of Business and Professional Regulation - Residential Performance Method <br /> Proje�t Name: Hayden 4EHB Elev D Builder Name: DRH Express Homes <br /> Street� �b g�-� ��('� ��,n� IL� Permit Office: <br />, City,S�tate,Zip: Zephyrhills,FL, `t�,l , / Permit Number: <br /> Owne�: � ���I � V Jurisdiction: <br /> Desi n Loca tion: F L Tam a <br /> 9,I � p r�// County:: Pasco(Florida Climate Zone 2) <br /> 1. New consVuction or existing New(From Plans) 9. Wall Types(2614.2 sqft.) Insulation Area <br /> 2. Singl family or multiple family Single-family a.Frame-Wood, Exterior R=11.0 1285.30 ftz <br /> I b.Concrete Block-Int Insul,Exterior R=4.1 996.67 ftz <br /> 3. Number of units,if multiple family 1 c.Frame-Wood,Adjacent R=11.0 332.22 ftz <br /> 4. Numper of Bedrooms 5 d.N/A R_ ftZ <br /> 5. Is thi�a worst case? No 10.Ceiling Types (1541.0 sqft.) Insulation Area <br /> � a.Under Attic(Vented) R=30.0 1541.00 ftz <br /> 6. Condl�tioned floor area above grade(ftz) 2605 b.N/A R= ftz <br /> Cond tioned floor area below grade(ftz) 0 c.N/A R= ftz <br /> 11. Ducts R ft2 <br /> 7. Windlows(250.0 sqft.) Description Area a.Sup:Attic,Ret:2nd Floor,AH:2nd Floor 6 261 <br /> a. U-Factor: Dbl,.U=0.34 210.00 ftz <br /> SF�GC: SHGC=0.31 <br /> b. U-Factor: Dbl,U=0.55 40.00 ftz 12.Cooling systems kBtu/hr Efficiency <br /> SF�GC: SHGC=0.34 a.Central Unit 40.0 SEER:14.00 <br />' c. U-F'Iactor: N/A ft2 <br /> SHGC: 13. Heating systems kBtu/hr Efficiency <br /> d. U-Factor: N/A ftz a.Electric Heat Pump 41.0 HSPF:8.20 <br /> SF�iIIG�C: <br /> Area WIeighted Average Overhang Depth: 1.692 ft. <br /> Area Weighted Ave�age SHGC: 0.315 14.Hot water systems <br /> I� a.Electric Cap:50 gallons <br /> 8. Floor Types (1541.0 sqft.) Insulation Area <br /> a.Sla�-On-Grade Edge Insulation R=0.0 1104.00 ftz b. Conservation features EF:0.950 <br /> b.Raised Floor R=19.0 437.00 ftz None <br /> c,N/AI R= ft2 15.Credits Pstat <br /> �� Total Proposed Modified Loads: 78.64 � w�� <br /> Glass/�loor Area: 0.096 Total Baseline Loads: 79.15 f�'� <br /> I hereby certify that the plans and specifications covered by Review of the plans and D��tH��?'R� <br /> this calc lation are in compliance with the Florida Energy specifications covered by this -� = � p <br /> Code. � calculation indicates compliance �'�„��'` _��,.� � <br /> � with the Florida Energy Code. � rm,,..'��•. :;i.;�,°;,,�°ti� O <br /> ,,... ..... <br /> PREPA ED BY: �'►'�-�� Before construction is completed u� � 'r � <br /> DATE: II-4-16 this building will be inspected for � �� ��{. � ,� <br /> compliance with Section 553.908 * * <br /> I hereby ertify.that this building, as designed,is in compliance Florida Statutes. ,� ,S <br /> with the II lorida Energy Code. �QD y��� <br /> OWNER/AGEN : BUILDING OFFICIAL: <br /> DATE: I 1� DATE: <br /> I <br /> - Compl'ance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as <br /> certifi d factory-sealed in accordance with R403.2.2.1. � <br /> -Compl'i nce requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and an envelope leakage <br /> test rep�rt in accordance with R402.4.1.2. <br /> i <br /> 1 1/4/201 6 2:05 PM EnergyGaugeCW USA-FlaRes2014 Section R405.4.1 Compliant Software Page 1 of 5 <br /> I <br /> I <br /> � - � <br /> i _ � <br />
The URL can be used to link to this page
Your browser does not support the video tag.