Laserfiche WebLink
� ' '� �� <br /> FORM R405-2014 <br /> CEILING <br /> I # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type <br /> 1 Under Attic(Vented) Main 30 Blown 40 ft2 0.11 Wood <br /> 2 Under Attic(Vented) 2nd Floor 30 Blown 1501 ftz 0.11 Wood <br /> WALLS <br /> Adjacent Space Cavity Width Height Sheathing Framing Solar Below <br /> 1 � N Exterior Concrete Block-Int Insul Main 4.1 18 8 8 8 161.8 ft2 0 0.6 0 <br /> 2, E Exterior Concrete Block-Int Insul Main 4.1 20 8 8 173.3 ft2 0 0.6 0 <br /> _3 I S Exterior Concrete Block-Int Insul Main 4.1 39 8 8 S 343.8 ftz 0 0.6 0 <br /> 4� W Exterior Concrete Block-Int Insul Main 4.1 36 8 8 8 317.8 ftz 0 0.6 0 <br />, _5 � N Garage Frame-Wood Main 11 20 4 8 8 176.2 ftz 0.23 0.01 0 <br />' _ 6 � E Garage Frame-Wood Main 11 1 S 0 8 8 156.0 ft2 0.23 0.01 0 <br /> 7 , N Exterior Frame-Wood 2nd Floor 11 39 8 8 317.3 ftz 0.23 0.6 0 <br /> S � E Exterior Frame-Wood 2nd Floor 11 40 8 8 325.3 ftz 0.23 0.6 0 <br /> - � <br /> 9 ' S Exterior Frame-Wood 2nd Floor 11 39 S 8 317.3 ftz 0.23 0.6 0 <br /> - i <br /> 10 W Exterior Frame-Wood 2nd Floor 11 40 S 8 325.3 ftz 0.23 0.6 0 <br /> DOORS <br />� � # Ornt Door Type Space Storms U-Value Width Height Area <br /> i Ft In Ft In <br /> ' 1 N Insulated Main None .4 3 6 8 20 ftz <br /> 2 N Wood Main None .46 2 8 6 8 17.8 ftz <br /> WINDOWS <br /> Orientation shown is the entered, Pro osed orientation. <br /> ` / � Wall Overhang <br /> V # Ornt ID Frame Panes NFRC U-Factor SHGC Area Depth Separation Int Shade Screening <br /> 1 N 1 Vinyl Low-E Double Yes 0.34 0.31 31.0 ftz 6 ft 2 in 1 ft 0 in Drapes/blinds None <br /> 2 N 1 Vinyl Low-E Double Yes 0.34 0.31 2.5 ftz 6 ft 2 in 0 ft 0 in Drapes/blinds None <br /> 3 S 3 Vinyl Low-E Double Yes 0.34 0.31 46.5 ft2 1 ft 0 in 10 ft 6 in Drapes/blinds None <br /> 4 S 3 Metal Low-E Double Yes 0.55 0.34 40.0 ftz 1 ft 0 in 1 ft 3 in Drapes/blinds None <br /> 5 N 7 Vinyl Low-E Double Yes 0.34 0.31 6.0 ftz 1 ft 0 in 0 ft 6 in Drapes/blinds None <br /> 6 N 7 Vinyl Low-E Double Yes 0.34 0.31 31.0 ftz 1 ft 0 in 2 ft 6 in Drapes/blinds None <br /> 7 S 9 Vinyl Low-E Double Yes 0.34 0.31 62.0 ftz 1 ft 0 in 0 ft 6 in Drapes/blinds None <br /> 8 N 7 Vinyl Low-E Double Yes 0.34 0.31 31.0 ftz 1 ft 0 in 0 ft 6 in Drapes/blinds None <br /> GARAGE <br /> I # Floor Area Ceiling Area Exposed Wall Perimeter Avg.Wall Height Exposed Wall Insulation <br /> 1 437.038 ft2 437.038 ftz 48.4 ft 8.67 ft 0 <br /> I <br /> 11/4/2 16 2:05 PM EnergyGaugeOO USA-FlaRes2014 Section R405.4.1 Compliant Software Page 3 of 5 <br /> i <br /> � <br /> I � <br />