Laserfiche WebLink
, <br /> FORM R405-2014 <br /> F ORIDA ENERGY EFFICIENCY CODE FOR BUlLDING CONSTRUCTION <br /> Florida Department of Business and Professional Regulation - Residential Performance Method <br /> Project Name: Hayden 4EHB Elev D Builder Name: DRH Express Homes <br /> Street: _�j/_ I�� '�ri��e �j�e �-� Permit Office: <br /> City� State,Zip: �2�iyrhills, FL, i1�`:r'!' , / Permit Number: <br /> Owr�er: �J ��� �VI Jurisdiction: - <br /> Design Location: FL,Tampa f�// County:: Pasco(Florida Climate Zone 2) <br /> ( <br /> 1. Nell construction or existing New(From Plans) 9. W all Types(2614.2 sqft.) Insulation Area <br /> 2. Sinl le family or multiple family Single-family a. Frame-Wood,Exterior R=11.0 1285.30 ftz <br /> � b.Concrete Block-Int Insul,Exterior R=4.1 996.67 ftz <br /> 3. Nu ber of units,if multiple family 1 c.Frame-Wood,Adjacent R=11.0 332.22 ft2 <br /> d.N/A <br /> 4. Nur�ber of Bedraoms 5 R= ftz <br /> �I. 10.Ceiling Types (1541.0 sqft.) Insulation Area <br /> 5. Is tIl is a worst case? No a.Under Attic Nented) R=30.0 1541.00 ftz <br /> 6. Co2ditioned floor area above grade(ftz) 2605 b.N/A R= ft2 <br /> Co ditioned floor area below grade(ft�) 0 c.N/A R= ftz <br /> � 11.Ducts R {�z <br /> 7. Wi dows(250.0 sqft.) Description Area a.Sup:Attic, Ret:2nd Floor,AH:2nd Floor 6 261 <br /> a. �-Factor: Dbl,U=0.34 210.00 ft2 <br /> HGC: SHGC=0.31 <br /> b. �-Factor: Dbl, U=0.55 40.00 ftz 12•Cooling systems kBtu/hr Efficiency <br /> � <br /> HGC: SHGC=0.34 a.Central Unit 40.0 SEER:14.00 <br /> c. -Factor: N/A ft2 <br /> HGC: 13.Heating systems kBtu/hr Efficiency <br /> d: �Factor: N/A ftz a.Electric Heat Pump 41.0 HSPF:8.20 <br /> SHGC: <br /> Are�Weighted Average Overhang Depth: 1.692 ft. <br /> Area Weighted Average SHGC: 0.315 14.Hot water systems <br /> � a.Electric Cap:50 gallons <br /> 8. Floo Types (1541.0 sqft.) Insulation Area EF:0.95D <br /> a.SI' On-Grade Edge Insulation� R=0.0 1104.00 ftz b. Conservation features <br /> b.R�iised Floor R=19.0 437.00 ftz None <br /> c.Wr R= ftZ 15.Credits Pstat <br /> �� Total Proposed Modified Loads: 78.51 � A c� <br /> Glass/IFloor Area: O.Q96 Total Basefine Loads: 79.15 f1�� <br /> I hereb�certify that the plans and spec'rfications covered by Review of the plans and O�THE Sx.g�,, <br /> this calculation are in compliance.with the Florida Energy specifications covered by this -,� = ��`�'p <br /> Code. calculation indicates compliance �'„°'y ='r',�� <br /> with the Florida Ener Code. � s„- ��• "�- r�" '� <br /> 9Y •,�_�''�,;.�, , a <br /> PREP RED BY: �'M11�-�� Before construction is completed rz� "` `�� � <br /> DATE i Ih4-16 this building will be inspected for � �'�;i ,�� <br /> compliance with Section 553.908 * �` ° <br /> . � <br /> I hereby certify that this building,as designed,is in compliance �orida Statutes. ,� �,t <br /> with th i Florida Energy Code. . �{�D�.�'� <br /> OWNE'R/AGENT' BUILDING OFFICIAL: <br /> DATE: DATE: <br /> i <br /> - Com �Iiance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as <br /> certified factory-sealed in accordance with R403.2.2.1. <br /> -Comp�iance requires an Air Barrier and Insulation Inspection Checklist in accordance with R4Q2.4.1.1 and an envelope leakage <br /> test report in accordance with R402.4.y.2. <br /> - Compliance with a proposed duct leakage Gln requires a Duct Leakage Test Report confirming duct leakage to outdoors, <br /> tested i�� accordance with Section 803 of RESNET Standards, is not greater than U.060 Qn for whole house. <br /> 11/4/20 6 4:18 PM EnergyGauge�USA-FlaRes2014 Section R4Q5.4.1 Compliant Software Page 1 of 5 <br />