s <br /> FORM 405-2014 ' <br /> INFILTRATION <br /> # Scope Method SLA CFM 50 ELA EqLA ACH ACH 50 <br /> i <br /> 1 W I alehouse Proposed ACH(50) .000368 2517.6 138.21 - 259.93 .3402 7 <br /> HEATING SYSTEM <br /> I # System Type Subtype Efficiency Capacity Block Ducts <br /> � 1 Electric Heat Pump None HSPF:8.2 41 kBtu/hr 1 sys#1 <br /> COOLING SYSTEM <br /> I # System Type Subtype Efficiency Capacity Air Flow SHR Block Ducis <br /> 1 Central Unit None SEER:14 40 kBtu/hr 1200 cfm 0.75 1 sys#1 <br /> HOT WATER SYSTEM <br /> I # System Type SubType Location EF Cap Use SetPnt Conservation <br /> 1 Electric None Garage 0.95 50 gal 70 gal 120 deg None <br /> SOLAR HOT WATER SYSTEM <br /> FSEC Collector Storage <br /> Cert # Company Name System Model# Collector Model# Area Volume FEF <br /> None None gz <br /> DUCTS <br /> / ----Supply---- ---Retum---- Air CFM 25 CFM25 HVAC# <br /> V # Location R-Value Area Location Area Leakage Type Handler TOT OUT QN RLF Heat Cool <br /> I 1 Attic 6 261 ftz 2nd Flaor 45 ftz Proposed Qn 2nd Floor ---cfm 156.3 cfm 0.06 0.60 1 1 <br /> TEMPERATURES <br /> Progr�mable Thermostat:Y Ceiling Fans: <br /> Coolin I r �Jan r 1Feb r lMar Apr May X�Jun Jul Aug Sep Oct Nov Dec <br /> Heatin [X]Jan [X]Feb [X]Mar E�Apr f �May f ]Jun f�Jul f�Au9 f�SeP E�Oct �Nov �Dec <br /> Ventin [ ]Jan [ J Feb [X]Mar [x]A r � Ma � ]Jun [ Jul [ Au [ Se [x]Oct Nov Dec <br /> 11/4/2 16 4:18 PM_ EnergyGaugeC�USA-FlaRes2014 Section R405.4.1 Compliant Software Page 4 of 5 <br />� li <br />