, , • . t <br /> � <br /> �uct System Sumsnary Job: Driftwood6Piex <br /> V1r�1����4�� Date: Jan 25,2016 <br /> �lnif 5 By: DJM <br /> ' • - . s <br /> For: Driftwood of Zephyrhills <br /> Zephyrhills, FL <br /> Heating Cooling <br /> External static pressure 0.53 in H20 0.53 in H20 <br /> Pressure losses 0 in H20 0 in H20 <br /> Available static pressure 0.53 in H20 0.53 in H20 <br /> Supply/return available pressure 0.265/0.265 in H20 0.265/0.265 in H20 <br /> Lowest friction rate 0.560 in/100ft 0.560 inl100ft <br /> Actual air fiow 580 cfm 580 cfm <br /> Total effective length(TEL) 95 ft <br /> • • : � - . . <br /> Design Htg Cig Design Diam H x W Duct Actual Ftg.Eqv <br /> Name (Btuh) (cfm) (cfm) FR (in) (in) Matl Ln(ft) Ln(ft) Trunk <br /> 5 sath h 496 32 21 0.715 4.0 Ox 0 VIFx 4.1 70.0 <br /> 5 Bed 1 h 2112 136 112 0.573 7.0 OX 0 VIFX 22.6 70.0 <br /> 5 eed 2 h 2336 150 111 0.560 7.0 Ox 0 VIFx 24.7 70.0 <br /> s�citcnen C 2181 15 112 0.649 6.0 Ox 0 VIFx 11.7 70.0 <br /> s�iviny h 1855 119 105 0.640 7.0 Ox 0 VIFx 12.8 70.0 <br /> 5 Living-A h 1855 119 105 0.677 7.0 Ox 0 VIFx 8.2 70.0 <br /> 5 M Balh C 150 5 8 0.679 4.0 OX 0 VIFX 8.1 70.0 <br /> a wic c 100 3 5 0.629 4.0 Ox 0 VIFx 14.3 70.0 <br /> : � • <br /> Grill Htg Clg TEL Design Veloc Diam H x W Stud/Joist Duct <br /> Name Size(in) (cfm) (cfm) (ft) FR (fpm) (in) (in) Opening(in) Matl Trunk <br /> rb6 Ox 0 580 580 0 0 0 0 Ox 0 VIFx <br /> 1A/1"I �I�SQ�' 2016�1an-26 08:15:44 <br /> ,�,�..., g Right-Suite�Universal 2015 15.0.21 RSU11033 Page 5 <br /> .�� ...le Drive\DocumentslSonnys\Driftwood 6 olex.rup Calc=MJB Front Door faces: E <br />