Laserfiche WebLink
i ' <br /> Single Family Dwelling <br /> Plan Review Comments <br /> 1. F.F.E. shall be a minimuin of 8" above the road elevation and an engineered site plan. <br /> 2. Lots shall be graded to coinply with R401.3 of the F.B.C. <br /> 3. Compaction test required if 24" or more of fill dirt is brought in at any one place. <br /> 4. Tie in survey required before pouring concrete. <br /> 5. Driveways require a R.O.W. use pei-�nit. A114 sides of driveway thru the sidewalk shall have <br /> expansion inaterial. <br /> 6. All setbacks shall be met. <br /> 7. All property markers shall be uncovered and inarked at tiine of first inspection. <br /> 8. All A.D.A. requirements shall be met. <br /> 9. No electric, plumbing, mechanical, or framing shall be covered without an inspection and <br /> approval first. <br /> 10. All Garages shall coinply with section R309.2 of the F.B.C. (Fire Separation). <br /> 1 l. Appliances shall not be installed in a location where subject to inechanical dainage unless <br /> protected by approved barriers. M303.4 of the F.B.0 <br /> 12. Water heaters shall coinply with section P607.3 of the .F.B.0 <br /> 13. Foundation supports for A/C units shall be raised at least 3" above finished grade. M1308.1 <br /> 14. Return air in all bedrooms. F.B.C. M1620.4 <br /> 15. Sinoke detectors are to be installed in accordance with R313.1 of the F.B.C. <br /> 16. All glazing requireinents are to be in accordance with R308.4 of the F.B.C. <br /> 17. All means of egress are to be in accordance with R311 of the F.B.C. <br /> 18. "Green gypsum board" shall not be used as a backer in showers or tubs. R702.4.2 F.B.C. <br /> 19. Combination-type AFCI breakers are required at all locations requiring an AFCI type breaker. <br /> 20. Carbon monoxide alanns will be required in new construction that uses fossil-burning heating <br /> or appliances or an attached garage. They shall be installed in accordance with the F.B.C. <br /> 21. All pluinbing, inechanical, and electrical shall be separate from unit to unit. This includes all <br /> underground pluinbing and electric. <br /> 22. All 2008 N.E.C. Codes will be enforced. <br /> 23. Tainper- Resistant Receptacles in accordance with 406.11 of the 2008 N.E.0 <br /> 22. In accordance with the Land Development Code, lots shall be sodded before final at least 10 <br /> feet around the structure. <br /> F.F.E.-Finished Floor Elevation <br />' F.B.G Florida Building Code(2010) <br /> R.O.W.-Right Of Way <br /> A.D.A.-Americans with Disabilities Act N.E.C.-National Electric Code(2008) <br /> - - - - -�= <br />