My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
17-16915
Zephyrhills
>
Building Department
>
Permits
>
2017
>
17-16915
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/8/2017 1:58:03 PM
Creation date
12/8/2017 1:58:01 PM
Metadata
Fields
Template:
Building Department
Company Name
DRIFTWOOD
Building Department - Doc Type
Permit
Permit #
17-16915
Building Department - Name
RYMAN CONSTR
Address
6750 BASSWOOD CIR LOT 37
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
24
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
� . . <br /> Pro ect Summa Job: Driftwood 6 Plex <br /> -�}-�yy�jg��sp�� 1 rY Date: Jan 25,so�s <br /> Unif 1 By: DJM <br /> ' • - • • <br /> For: Driftwood of Zephyrhills <br /> Zephyrhills, FL <br /> Notes: <br /> � - • • • <br /> Weather: Tampa, FL, US <br /> Winter Design Conditions Summer Design Conditions <br /> Outside db 41 °F Outside db 91 °F <br /> Inside db 70 °F Inside db 75 °F <br />' Design TD 29 °F Design TD 16 °F <br /> Daily range L ! ' <br /> Relative humidity 50 % � <br /> Moisture difference 56 gr/Ib <br /> Heating Summary Sensible Cooling Equipment Load Sizing � <br /> Structure 11107 Btuh Structure 9664 Btuh <br /> Ducts 2523 Btuh Ducts 3495 Btuh <br /> Central vent(0 cfm) 0 Btuh Central vent(0 cfm) 0 Btuh <br /> Humidification 0 Btuh Blower 0 Btuh <br /> Piping 0 Btuh <br />' Equipment load 13630 Btuh Use manufacturer's data n <br /> Rate/swing multiplier 0.96 <br /> Infiltration Equipment sensible load 12686 Btuh <br /> Method Simplified Latent Cooling Equipment Load Sizing <br /> Construction quality Average <br /> Fireplaces 0 Structure 2363 Btuh <br /> i Ducts 820 Btuh <br /> Heating Cooling Central vent(0 cfm) 0 Btuh <br /> Area(ftz) 1213 1213 Equipment latent load 3183 Btuh <br /> Uolume(fN) 10449 10449 <br /> Air changes/hour 0.44 0.24 Equipment total load 15869 Btuh <br /> Equiv.AVF(cfm) 77 41 Req.total capacity at 0.70 SHR 1.5 ton <br /> Heating Equipment Summary Cooling Equipment Summary <br /> Make Carrier Make Carrier <br /> Trade CARRIER Trade CARRIER <br /> Model 25HBC318(A,W)"`30 Cond 25HBC318(A,W)*"30 <br /> AHRI ref 5950184 Coil F84CNP018 <br /> AHRI ref 5950184 <br /> Efficiency 8.2 HSPF Efficiency 11.5 EER, 14 SEER <br /> Heating input Sensible ceoling 12180 Btuh <br /> Heating output 17400 Btuh @ 47°F Latent cooling 5220 Btuh <br />' Temperature rise 27 °F Total cooling 17400 Btuh <br />� Actual air flow 580 cfm Actual air flow 580 cfm <br /> Air flow factor 0.043 cfm/Btuh Air flow factor 0.044 cfm/Btuh <br /> Static pressure 0.53 in H20 Static pressure 0.53 in H20 <br /> Space thermostat Load sensible heat ratio 0.81 <br /> Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. <br /> � ��; ����� 2016-Jan-26 08:15:44 <br /> ��� }� RlghtSuite�Universal 2015 15.0.21 RSU11033 Page 1 <br /> ...le Drive\DocumentslSonny's\Driftwood 6 plex.rup Calc=MJ8 Front Door'aces: E <br />
The URL can be used to link to this page
Your browser does not support the video tag.