Laserfiche WebLink
'�. �t.i���$a� ��ICt S stem Summa Job: Driftwood 6 Plex <br /> y � Date: Jan 25,2016 <br /> Unit 1 By: DJM <br /> ' • - • • <br /> For: Driftwood of Zephyrhills (o�SD '�SSWac7oE ��rite- � �3� <br /> Zephyrhills, FL <br /> Heating Cooling <br /> External static pressure 0.53 in H20 0.53 in H20 <br /> Pressure losses 0 in H20 0 in H20 <br /> Available static pressure 0.53 in H20 0.53 in H20 <br /> Supply/return available pressure 0.265/0.265 in H20 0.265/0.265 in H20 <br /> Lowest friction rate 0.560 in/100ft 0.560 in/100ft <br /> Actual air flow 580 cfm 580 cfm <br />� Total effective length(TEL) 95 ft <br /> • • : � ' . • <br /> i <br /> Design Htg Clg Design Diam H x W Duct Actual Ftg.Eqv ; <br /> Name (Btuh) (cfm) (cfm) FR (in) (in) Matl Ln(ft) Ln(ft) Trunk � <br /> 88w h 438 19 16 0.715 4.0 Ox 0 VIFx 4.1 70.0 <br />' eed� C 2022 79 89 0.573 6.0 OX 0 VIFx 22.6 70.0 <br /> Bed 2 h 4023 171 120 0.560 8.0 Ox 0 VIFx 24.7 70.0 <br /> Kitchen c 2459 60 108 0.649 6.0 Ox 0 VIFx 11.7 70.0 <br /> �ivin9 h 2894 123 118 0.670 7.0 Ox 0 VIFx 9.1 70.0 <br /> Living-A h 2894 123 118 0.635 7.0 Ox 0 VIFx 13.5 70.0 <br /> �n eatn p 139 3 6 0.679 4.0 Ox 0 VIFx 8.1 70.0 <br /> W�� c 93 2 4 0.629 4.0 Ox 0" VIFx 14.3 70.0 <br /> - - e - . <br /> - <br /> Grill Htg Clg TEL Design Veloc Diam H x W Stud/Joist Duct <br /> Name Size(in) (cfm) (cfm) (ft) FR (fpm) (in) (in) Opening(in) Matl Trunk <br /> rb3 Ox 0 580 580 0 0 0 0 Ox 0 VIFx <br /> 2016-Jan-26 08:15:44 <br /> .e"�-„ '� wc�ightsaft' RightSuite�Univarsal 2015 15.0.21 RSU11033 Page 1 <br /> �. <br /> �� ...le Drive\DocumentslSonny's\Driflwood 6 piex.rup Calc=MJB Front Door faces: E <br />