Laserfiche WebLink
� � i <br /> -2 14 <br /> FORM R405 0 <br /> FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION <br /> Florida Department of Business and Professional Regulation - Residential Performance Method <br /> Project Name: Elle Elevation D Builder Name: ��•` � <br /> Street: ��zc ��riQ�Q�PO���� Permit Office: �b�z.i d-���Y-�i�°I�g <br /> City,State,Zip: Zephyrhills,FL�.�1 J�jyJ Permit Number: J 7�t Z� <br /> O w n e r: R� �v J u r i s d i c t i o n: �Q l�60 Z� <br /> Design Location: FL,Tampa l��/ County:: Pasco(Florida Climate Zone 2) <br /> 1. New construction or existing New(From Plans) 9. Wall Types(2595.2 sqft.) Insulation Area <br /> 2. Single family or multiple family Single-family a.Frame-Wood, Exterior R=11.0 1253.30 ftz <br /> b.Concrete Block-Int Insul,Exterior R=4 1 1084.80 ftz <br /> 3. Number of units,if multiple family 1 c.Frame-Wood,Adjacent R=11.0 257.11 ftz <br /> 4. Number of Bedrooms 5 d.N/A R= ftz <br /> 5. Is this a worst case? No 10.Ceiling Types (1534.0 sqft.) Insulation Area 2 <br /> a.Under Attic(Vented) R=30.0 1534.00 ft <br /> 6. Conditioned floor area above grade(ftz) 2807 b.N/A R= ft2 <br /> Conditioned floor area below grade(ft2) 0 c.N/A R= ftz <br /> 11.Ducts R ftz <br /> 7. Windows(267.5 sqft.) Description Area a.Sup:Attic, Ret:2nd Floor,AH:2nd Floor 6 265 <br /> a. U-Factor: Dbl, U=0.34 227.50 ftz <br /> SHGC: SHGC=0.31 <br /> b. U-Factor: Dbl, U=0.55 40.00 ftz 12.Cooling systems kBtu/hr Efficiency <br /> SHGC: SHGC=0.34 a.Central Unit 40.0 SEER:14.00 <br /> c. U-Factor: N/A ft2 <br /> SHGC: 13.Heating systems kBtu/hr Efficiency <br /> d. U-Factor: N/A ftz a.Electric Heat Pump 41.0 HSPF:8.20 <br /> SHGC: <br /> Area Weighted Average Overhang Depth: 1.626 ft. <br /> I Area Weighted Average SHGC: 0.314 14 Hot water systems <br /> S. Floor Types (1534.0 sqft.) Insulation Area a.Electric Cap:50 gallons <br /> EF:0.950 <br /> a.Slab-On-Grade Edge Insulation R=0.0 1314.00 ft2 b. Conservation features <br /> b.Floor over Garage R=19.0 220.00 ftz None <br /> c.N/A R= ftz 15.Credits Pstat <br /> Total Proposed Modified Loads: 81.77 <br /> Glass/Floor Area: 0.095 Total Baseline Loads: 81.77 PASS <br />, I hereby certify that the plans and specifications covered by Review of the plans and .�THE ST,q?, <br /> this calculation are in compliance with the Florida Energy specifications covered by this � � � �0�, <br /> ,, .a a,. <br /> Code. calculation indicates compliance � �,,, ' = ,�� Yr <br /> r <br /> with the Florida Energy Code. h rr,a,�`'�,�:.f;:�•;:;,��`„ O <br /> PREPARED BY: Before construction is completed � y;, '"�` " � <br /> DATE: � - - this building will be inspected for � `"I:.;�� . �. <br /> r�'E: <br /> compliance with Section 553.908 * ° �. <br /> I hereby certify that this building,as designed, is in compliance Florida Statutes. .t� ��. <br /> with the Florida Energy Code. e�D y�'L'�� <br /> OWNER/AGENT: BUILDING OF ICIA . � <br /> DATE: DATE: � <br /> - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as <br /> certified factory-sealed in accordance'with R403.2.2.1. <br /> -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and an envelope leakage <br /> test report in accordance with R402.4.1.2. <br /> 1 0/28/201 6 8:19 AM EnergyGauge�USA-FlaRes2014 Section R405.4.1 Compliant Software Page 1 of 5 <br />