Laserfiche WebLink
f ` <br /> .FORM F2405-2014 <br /> FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION <br /> Florida Department of Business and Professional Regulation - Residential Performance Method <br />� Project Name: Hartley Builder Name: /�� e'p�yj ��" <br /> Street: ' Permit Office: daesee�G vi-2 h+�(i 5 - <br /> � <br /> City,State,Zip: ,FL, Permit Number• �t3 d�a �� <br /> Owner Bo Hartley Jurisdiction: (Q ((�� <br /> Design Location: FL,Tampa County• Pasco(Florida Climate Zone 2) <br /> 1 New construction or existing New(From Plans) 9. Wall Types(1530.0 sqft.) Insulation Area <br /> 2. Single family or multiple family Single-family a.Frame-Wood,Exterior R=11.0 1242.00 ft' <br /> b.Frame-Wood,Adjacent R=11.0 288.00 ft2 <br /> 3. Number of units,if multiple family 1 c.N/A R- ft� I <br /> 4 Number of Bedrooms 3 d.N/A R_ ftZ <br /> 5. Is this a worst case? No 10.Ceiling Types (1410.0 sqft.) Insulation Area I <br /> a.Under Attic(Vented) R=38.0 1410.00 ftZ <br /> 6. Conditioned floor area above grade(ft') 1410 b.N/A R= ftZ <br /> Conditioned floor area below grade(ft2) 0 ' c.N/A R= ft2 <br /> 11.Ducts R ft2 <br /> 7 Windows(201.0 sqft.) Descnption Area a.Sup:Attic,Ret:Attic,AH:Garage 6 200 <br /> a. U-Factor: Dbl,U=0.27 201.00 ftZ <br /> SHGC: SHGC=0.22 <br /> b. U-Factor: N/A �{z 12.Cooling systems kBtu/hr Efficiency <br /> SHGC: a.Central Unit 22.0 SEER:14.00 � <br /> c. U-Factor N/A ft' I <br /> SHGC: 13.Heating systems kBtu/hr Efficiency <br /> d. U-Factor: N/A ft' a.Electric Heat Pump 22.0 HSPF:8.20 <br /> SHGC: <br />, Area Weighted Average Overhang Depth: 1.000 ft. <br /> Area Weighted Average SHGC: 0.220 14.Hot water systems <br /> a.Electric Cap:40 gallons <br /> 8. Floor Types (1410.0 sqft.) Insulation Area EF:0.950 <br /> a.Slab-On-Grade Edge Insulation R=0.0 1410.00 ftz b. Conservation features <br /> b.N/A R= ft2 None <br /> c.N/A R= ft2 15.Credits CF,Pstat . <br /> Total Proposed Modified Loads: 45.00 PASS <br /> Glass/Floor Area: 0. 3 <br /> Total Baseline Loads: 48.74 <br /> I hereby certify that the a s and specifications covered by Review of the plans and �'��E�TqT <br /> this calculation are in p'ance with the Florida Energy specifications covered by this b� = s .�OY,�, <br /> Code. calculation indicates compliance � y'��,,,�'''' �==''.�� ,��, <br /> fr� �ttu.>�'�',;s==:F:�``��. <br /> with the Florida Energy Code. ,.,•;.,� « O <br /> PREPARED BY: ._ �/- Before construction is completed � ;r , '. � <br /> DATE: this building will be inspected for � '��t� ` - � <br /> ��Ei� <br /> compliance with Section 553.908 * " ,, <br /> I hereby certify that this building, as d sig d, is in compliance Florida Statutes. � ��C,. <br /> with the Florida Energ od . ��a WE'�� <br /> OWNER/AGENT: `�""' � BUILDING O I-C�{9, �: <br /> DATE: 1�-r_lo'L-ao�l� DATE: ���"G ll <br /> - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as <br /> certified factory-sealed in accordance with R403.2.2.1. <br /> -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and an envelope leakage <br /> test report in accordance with R402.4.1.2. <br /> - Compliance with a proposed duct leakage Qn requires a Duct Leakage Test Report confirming duct leakage to outdoors, <br /> tested in accordance with Section 803 of RESNET Standards,is not greater than 0.030 Qn for whole house. <br /> 12/8/2016 3:00 PM EnergyGaugeC�USA-FlaRes2014 Section R405.4 1 Compliant Soflware Page 1 of 4 <br />