17-18164
Zephyrhills
>
Building Department
>
Permits
>
2017
>
17-18164
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/12/2017 11:45:03 AM
Creation date
12/12/2017 11:44:48 AM
Metadata
Fields
Template:
Building Department
Company Name
SILVER OAKS
Building Department - Doc Type
Permit
Permit #
17-18164
Building Department - Name
HARNDEN,JEFFREY & AUDREY
Address
6840 STEPHENS PATH
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
22
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Existing Structural Elements Carrying Gravity Load <br /> 2015 International Existing Building Code Section 707.2 <br /> 2015 International Residential Code Section AJ501.4 <br /> 2014 Florida Building Code-Residential Sth Edition,Section AJ104.1 <br /> Existing <br /> Roof Dead Load Roof Live Load <br /> 4 psf Composite Shingle 20 psf <br />' 2 psf 3/4"Plywood Sheathing <br /> 1 psf Roof Framing @ 24 in.o.c. Ground Snow Load <br /> 0 psf Ceiling,Mechanical,Electrical 20 psf <br /> 1 psf Miscellaneous <br /> 8 psf TOTAL <br /> Wall Dead Load <br /> 8 ft Wall Height <br /> 300 ft Wall Length <br /> 12 psf Wall Weight <br /> Additional <br /> Roof Dead Load Roof Live Load with Solar Panels <br />� 2.6 psf Solar Panel Weight 0 psf <br /> Total per Rafter <br /> Total Existing Roof Load=DLRooF+(LLRooF or Snow)x Spacing <br /> 56.04 pif <br /> Total New Roof Load=DLRooF+DLADD+(LLRooF or Snow)x Spacing <br /> 43.15 plf <br /> Change in Demand=(Total New Load-Existing Load)/Existing Load <br /> -23.00% <br />' Total New Gravity Loads are less than Existing Loads. OK <br />, 2015 IEBC Section 707.2 states: <br /> "Where addition or replacement of roofing or replacement of equipment results in additional dead loads,structural components supporting <br /> such reroofing or equipment shall comply with the gravity load requirements of the International Building Code requirements. <br /> EXCEPTION 1.Structural elements where the additional dead load from the roofing or equipment does not increase the force in the <br /> , element by more than 5 percent." <br /> 2015IRC Section AJ501.4 states: <br /> "The minimum design loads for the structure shall be the loads applicable at the time the building was constructed,provided that a <br />� dangerous condition is not created.Structural elements that are uncovered during the course of the alteration and that are found to be <br /> unsound or dangerous shall be made to comply with the applicable requirements of this code." <br /> 2014 Florida Building Code-Res�dential5th Edition,Section AJ104.1 states: <br /> � "Detached one-or rivo-family dwellings that are not irregular buildings under Section R301.2.2.2.5 and are not undergoing an extensive <br /> reconsh•uction shall not be required to be evaluated." <br /> � Sheet 2 of 3 � � - , ' <br /> � ' �� � - -.; <br />