17-18185
Zephyrhills
>
Building Department
>
Permits
>
2017
>
17-18185
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/12/2017 1:07:18 PM
Creation date
12/12/2017 1:06:56 PM
Metadata
Fields
Template:
Building Department
Company Name
OAK CREST ESTATES
Building Department - Doc Type
Permit
Permit #
17-18185
Building Department - Name
POSTON,MICHAEL & JACQUELINE
Address
6903 OAKCREST WAY
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
39
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
� <br /> 6"MAX.(TYP) 18"MAX.O.C.(TVP.) � �/'� �� <br /> 6"MAX.(TYP.) 18"MAX.O.C.(TYP.) 6"MAX. 18"MAX.O.C. I! j]/]_(���fjf]'Va1/d <br /> �8.'MAX. � (TYP.) � ��-�iycsa�i(�lWUuucr p/lf`f.J <br /> I 6"MAX.(TlP.) 8"MAX. 8"MAX. WIVIIDOW SYSTED9S I\�✓� <br /> SEE NOTE 2 I SEE NOTE 2 6 MAx' SEE NOTE 2 <br /> (TYP.) 1900 SW 44TH AVE. <br /> � � OCALA,FLORIDA 34474 <br /> 6"MAX.(TYP) I <br /> WWW.CWS.CC <br /> � � �T 8"MAX.O.C.(TYP.) <br /> 18"MAX.O.C.(TYP) I 18"MAX.O.C.(TYP.) � 3500 ALUM. <br /> �- O i -j- O O SINGLE HUNG <br /> NON-IIVIPACT <br /> I <br /> I ` �, � N � <br /> INSTALLATION I INSTALLATIQN q �° { �n N w <br /> ANCHORS(TYP) � F- <br /> I ANCHORS,THRU 4" o 0 0 � � <br /> FRAMEATJAMBS <br /> I (SEE NOTE 2,SHT 6) y <br /> � INSTALLATION w m <br /> ANCHORS,THRU <br /> I CLIPS AT ALL �+ � � <br /> X I X SIDES X m ` � m � <br /> 4 ' 4 � � � � `� <br /> > <br /> SEE NOTE 2 I 4 �" � o �' O � <br /> I � o w � a <br /> o � � o <br /> — � —— —————— � � w � � <br /> I U <br /> � <br /> INSTALLATION ANCHORS, � � � � p <br /> I THRU CLIPS AT SILL �� <br /> ANCHOR LAYOUT-(FLANGEI FOR DP CHART A ANCHOR LAYOUT-IFLANGE)FOR DP CHART B o � m a O <br /> THFU FRAME OR CLIP�MASONRV OR WOOD OPENING) I THRU FflAME OR CLIP(MASONRY OR WOOD OPENING) Z <br /> �P LIMITED BV GLASS AN�TESTED PRESSURE LIMITATIONS.SEE SHEET 5 I DP LIMITEO BY ANCHOR CLIPS,SEE SHEET fi ,,t�lt II If���' <br /> � ------ -----------------�---------------- -- -------- -------------------- �`���PNORE4yT4ii <br /> NOTES: i 4"MAX.(TYPI )� �� 16"MAX.O.G(TYP.) `:��P�•4�G E/J SF G�Q'�� <br /> L �v�� No 58201 '�7}� <br /> . 1 INSTALL ONE ANCHOR AT EACH LOCATION. SILL ANCHOR SPACING SAME AS HEAD I q"MqX�(Typ� �*: * :,�: <br /> ' 2.SHIM AS REQ'D AT EACH SET OF INSTALLATION ANCHORS USING LOAD BEARING SHIMS. MAX.ALLOWABLE SHIM STACK TO BE 1/4" USE � is"MAX.O.C. :�=, STaTE oF ��: <br /> SHIMS WHERE SPACE GREATER THAN 1/16 IS PRESENT LOAD BEARING SHIMS SHALL BE CONSTRUCTED OF HIGH DENSITY PLASTIC OR (n'P•) .,p; ;e�� <br /> � ..o•.F P: � <br /> BETTER.WOOD SHIMS ARE NOT ALLOWED I � �� ( ,7: �_�� <br /> $"'.OR1 <br /> 4��ss'�. .E�C?��� <br /> 3.ANCHOR TYPE,SIZE,SPACING AND EMBEDMENT SHALL BE SPECIFIED IN THESE DRAWINGS,SEE TABLE 1,SHEET 10. � �r��ONpG t��� <br /> 0 �n n� <br /> nn <br /> 4 ALL INSTALLATION ANCHORS MUST BE MADE OF OR COATED WITH A CORROSION RESISTANT MATERIAL.DISSIMILAR MATERIALS OR � �Z <br /> MATERIALS IN CONTACT WITH PRESSURE TREATED WOOD MUST BE PROTECTED TO PREVENT REACTION. � 2/23/2015 <br /> 5.INSTALLATION ANCHORS SHALL BE IN ACCORDANCE WITH ANCHOR MANUFACTURER'S INSTALLATION INSTRUCTIONS,AND ANCHORS SHALL I <br /> I 3" LUCAS A.TURNER,P.E. <br /> NOT BE USED IN SUBSTRATES WITH STRENGTHS LESS THAN THE MINIMUM SPECIFIED IN TABLE 1,SHEET 10. FL PE#58201 <br />' � 3„ 1239 JABARA AVE. <br /> 6.ANCHOR EMBEDMENT TO SUBSTRATE SHALL BE BEYOND WALL DRESSING OR STUCCO. FOR CONCRETE/CMU OPENINGS,EMBEDMENT NORTH PORT,FL 34288 <br /> SHALL BE BEYOND WOOD BUCKS,IF USED,AND INTO SUBSTRATE-1X BUCKS ARE OPTIONAL. II PH.941-380-1574 <br /> 7 A MINIMUM 3"CENTER-TO-CENTER SPACING SHALL BE MAINTAINED BETWEEN ALL MASONRY FASTENERS. A MINIMUM 1" IrvSTALLATioN SHEET DESCRIPTION: <br /> I ANCHORS(TYP) <br /> CENTER-TO-CENTER SPACING SHALL BE MAINTAINED BETWEEN ALL WOOD AND METAL FASTENERS. I ANCHOR SCHEDULE AND <br /> 8.WOOD OR MASONRY OPENINGS,BUCKS AND BUCK FASTENERS SHALL BE PROPERLY DESIGNED BY THE ARCHITECT OR ENGINEER OF I 4 NOTES-EQUAL SPLIT <br /> RECORD AND INSTALLED TO TRANSFER WIND LOADS TO THE STRUCTURE. SUBSTRATES SHALL MEET THE MINIMUM STRENGTH I DRAWN BV DA7E: <br /> RE�UIREMENTS AS SHOWN IN TABLE 1,SHEET 10. CONCRETE AND MASONRY SUBSTRATES SHALL NOT BE CRACKED I ADE 03/16/09 <br /> ———— DWG#� REV.� <br /> , 9.SEALING AND FLASHING STRATEGIES FOR OVERALL WATER RESISTANCE OF INSTALLATION SHALL BE DONE BY OTHERS FOLLOWING THE I CWS-466 D <br /> CURRENT VERSION OF THE REFERENCE DOCUMENTS: � ANCHOR LAYOUT-(FINI FOR DP CHART A <br /> FMA/AAMA 100 FIN WINDOWS,FMA/AAMA200 FLANGE WINDOWS� THRUNAILINGFIN�WOODOPENING) scn�e: SHEET <br /> � � � � I DP LIMITED BV GLASS AND TESTED PRESSURE LIMITATIONS.SEE SHEET 5 <br /> FMA/WDMA250(BOXWINDOWS),FMA/AAMA/WDMA300(EXTERIORDOORS). 1:25 g pF�� <br />