17-18229
Zephyrhills
>
Building Department
>
Permits
>
2017
>
17-18229
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/12/2017 2:02:06 PM
Creation date
12/12/2017 2:02:04 PM
Metadata
Fields
Template:
Building Department
Company Name
SILVERADO
Building Department - Doc Type
Permit
Permit #
17-18229
Building Department - Name
LENNAR HOMES LLC
Address
6592 PADEN WHEEL ST
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
27
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
FORM R405-2014 <br /> DOORS <br /> # Ornt Door Type Space Storms U-Value Width Height Area <br /> Ft In Ft In <br /> 1 N=>NW Insulated foyer None .2 3 6 8 20 ftz <br /> 2 E=>NE Wood nook None .2 2 8 6 8 17.8 ftZ <br /> 3 N=>NW Wood laundry None .4 2 8 6 8 17.8 ftZ <br /> WINDOWS <br /> Orientation shown is the entered orientation(_> chan ed to Worst Case. <br /> / Wall Overhang <br /> \� # Ornt ID Frame Panes NFRC U-Factor SHGC Area Depth Separation Int Shade Screening <br /> 1 S=>SE 2 Metal Low-E Double Yes 0.54 0.31 32.0 ftz 1 ft 0 in 1 ft 7 in None None <br /> 2 E=>NE 6 Metal Low-E Double Yes 0.54 0.31 12.0 ftz 1 ft 0 in 1 ft 7 in None None <br /> 3 N=>NW 8 Metal Low-E Double Yes 0.56 0.28 4.0 ftZ 6 ft 0 in 0 ft 4 in None None <br /> 4 N=>NW 10 Metal Low-E Double Yes 0.56 0.28 22.7 ftZ 6 ft 0 in 0 ft 4 in None None <br /> 5 E=>NE 11 Metal Low-E Double Yes 0.54 0.31 16.0 ftz 1 ft 0 in 1 ft 7 in None None <br /> 6 W=>SW 15 Metal Low-E Double Yes 0.54 0.31 16.0 ftz 1 ft 0 in 1 ft 7 in None None <br /> 7 W=>SW 17 Metal Low-E Double Yes 0.54 0.31 16.0 ftz 1 ft 0 in 1 ft 7 in None None <br /> 8 W=>SW 18 Metal Low-E Double Yes 0.54 0.31 16.0 ft2 1 ft 0 in 1 ft 7 in None None <br /> 9 SE=>E 22 Metal Low-E Double Yes 0.54 0.31 16.0 ft2 8 ft 0 in 0 ft 4 in None None <br /> 10 S=>SE 23 Metal Low-E Double Yes 0.54 0.31 16.0 ftZ 1 ft 0 in 1 ft 7 in None None <br /> 11 S=>SE 24 Metal Low-E Double Yes 0.58 0.32 64.0 ftz 9 ft 0 in 0 ft 4 in None None <br /> GARAGE <br /> # FloorArea Ceiling Area Exposed Wall Perimeter Avg.Wall Height Exposed Wall Insulation <br /> 1 574 ftZ 384 ftz 61.5 ft 9.3 ft 1 <br /> INFILTRATION <br /> # Scope Method SLA CFM 50 ELA EqLA ACH ACH 50 <br /> 1 Wholehouse Proposed ACH(50) .000299 1697.3 104.16 195.88 .2241 5 <br /> HEATING SYSTEM <br /> # System Type Subtype Efficiency Capacity Block Ducts <br /> 1 Electric Heat Pump Split HSPF:8.7 32.8 kBtu/hr 1 sys#1 <br /> COOLING SYSTEM <br /> # System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts <br /> 1 Central Unit Split SEER:15.2 34.8 kBtu/hr cfm 0.85 1 sys#1 <br /> 1/3/2017 835 AM EnergyGauge�USA-FlaRes2014 Section R405 4 1 Compliant Software Page 5 of 6 <br />