17-18230
Zephyrhills
>
Building Department
>
Permits
>
2017
>
17-18230
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/12/2017 2:03:08 PM
Creation date
12/12/2017 2:03:06 PM
Metadata
Fields
Template:
Building Department
Company Name
SILVERADO
Building Department - Doc Type
Permit
Permit #
17-18230
Building Department - Name
LENNAR HOMES LLC
Address
6611 PADEN WHEEL ST
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
24
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
f <br /> � a <br /> Manual S Compliance Report Job: 2268sf <br /> Date: 1/312017 <br /> Entire House By: Dave <br /> � Bayonet Plumbing Heating and Cooling <br /> 6950 New York Ave,Hudson <br /> � • ' • � <br /> For: Lennar Homes <br /> . . • . . <br /> Design Conditions <br /> Outdoor design DB 91.3°F Sensible gain: 28578 Btuh Entering coil DB 75.6°F <br /> Outdoor design WB: 77.3°F Latent gain: 3170 Btuh Entering coil WB• 62.8°F <br /> Indoor design DB� 75.0°F Total gain: 31748 Btuh <br /> Indoor RH 50% Estimated airflow� 1200 cfm <br /> Manufacturer's Performance Data atActual Design Conditions <br /> I Equipment type: SpIitASHP <br /> Manufacturer: Lennox Model: 14HPX-036-230-18+CBX27UH-036-230"++TDR <br /> Actual airflow• 1200 cfm <br /> Sensible capacity� 29581 Btuh 104% of load <br /> Latent capacity: 5220 Btuh 165% of load <br /> Total capacity� 34801 Btuh 110% of load SHR. 85% <br /> • • • <br /> Design Conditions <br /> � Outdoor design DB. 30.8°F Heat loss. 33476 Btuh Entering coil DB. 69.6°F <br /> Indoor design DB� 70.0°F <br /> Manufacturer's Performance Data atActual Design Conditions <br /> Equipment type: SpIitASHP <br /> Manufacturer: Lennox Model: 14HPX-036-230-18+CBX27UH-036-230"++TDR <br /> Actual airflow: 1200 cfm <br /> Output capacity� 32800 Btuh 98% of load Capacity balance: 38 °F <br /> Supplemental heat required: 676 Btuh Economic balance: -99 °F <br /> Backup equipment type: Elec strip <br /> Manufacturer: n/a Model: Na+n/a <br /> Actual airflow: 1200 cfm <br /> Output capacity: 0 kW 0% of load Temp. rise: 0 °F <br /> The above equipment was selected in accordance with ACCA Manual S. <br /> ,�. wri htsoft� 2017-Jan-03 09:39:37 <br /> ,,." 9 Right-Suiie�Universal 2013 13.0.09 RSU05714 Page 1 <br /> �'� H:\LENNAR LOADS\2268 sf ADS drawn 3 ton.rup Calc=MJB Front Door faces: E <br />