My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
17-18230
Zephyrhills
>
Building Department
>
Permits
>
2017
>
17-18230
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/12/2017 2:03:08 PM
Creation date
12/12/2017 2:03:06 PM
Metadata
Fields
Template:
Building Department
Company Name
SILVERADO
Building Department - Doc Type
Permit
Permit #
17-18230
Building Department - Name
LENNAR HOMES LLC
Address
6611 PADEN WHEEL ST
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
24
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
l � <br /> FORM R405-2014 <br /> - WALLS <br /> ' Adjacent Space Cavity Width Height Sheathing Framing Solar Belo w <br /> 1 N Exterior Concrete Block-Int Insul Main 4 1 12 8 9 4 118.2 ftZ 0 0 0.6 0 � <br /> 2 S Exterior Concrete Block-Int Insul Main 4.1 31 4 9 4 292.4 ft2 0 0 0.6 0 <br /> 3 E Exterior Concrete Block-Int Insul Main 4.1 64 0 9 4 597.3 ftZ 0 0 0.6 0 <br /> 4 W Exterior Concrete Block-Int Insul Main 4 1 75 9 4 700.0 ftZ 0 0.6 0 <br /> _5 N Garage Frame-Wood Main 11 28 0 9 4 261.3 ftx 0.23 0.01 0 <br /> _6 E Garage Frame-Wood Main 11 11 0 9 4 102.7 ft2 0.23 0.01 0 <br /> 7 N Exterior Concrete Block-Int Insul Main 4.0999 4 8 11 4 52.9 ft2 0 0.600000 0 <br /> 8 S Exterior Concrete Block-Int Insul Main 4.0999 15 4 9 4 143.1 ft2 0 0.600000 0 <br /> DOORS <br /> # Ornt Door Type Space Storms U-Value Width Height Area <br /> Ft In Ft In <br /> 1 N Insulated Main None .2 3 6 8 20 ftZ <br /> 2 N Wood Main None 4 2 8 6 8 17.8 ftZ <br /> WINDOWS <br /> Orientation shown is the entered orientation => chan ed to Worst Case. <br /> , / Wall Overhang � <br /> V # Ornt ID Frame Panes NFRC U-Factor SHGC Area Depth Separation Int Shade Screening I <br /> 1 N 7 Metal Low-E Double Yes 0.56 0.28 6.0 ftz 5 ft 0 in 0 ft B in None None i <br /> 2 N 1 Metal Low-E Double Yes 0.56 0.28 32.0 ft� 1 ft 0 in 1 ft 6 in Drapes/blinds Exterior 5 <br /> 3 S 2 Metal Low-E Double Yes 0.54 0.31 48.0 ftz 1 ft 0 in 0 ft B in Drapes/blinds Exterior 5 <br /> 4 S 8 Metal Low-E Double Yes 0.58 0.32 96.0 ftZ 10 ft 0 in 0 ft 2 in Drapes/blinds Exterior 5 <br /> 5 E 3 Metal Low-E Double Yes 0.54 0.31 23.0 ft2 1 ft 0 in 0 ft 8 in None None <br /> 6 E 3 Metal Low-E Double Yes 0.54 0.31 12.0 ftz 1 ft 0 in 0 ft 8 in Drapes/blinds Exterior 5 <br /> 7 W 4 Metal Low-E Double Yes 0.54 0.31 48.0 ftz 1 ft 0 in 0 ft B in Drapes/blinds Exterior 5 <br /> 8 W 4 Metal Low-E Double Yes 0.54 0.31 12.0 ftz 1 ft 0 in 0 ft 8 in Drapes/blinds Exterior 5 <br /> GARAGE <br /> # FloorArea Ceiling Area Exposed Wall Perimeter Avg.Wall Height Exposed Wall Insulation <br /> 1 595 ftZ 595 ft2 60.2 ft 9.3 ft 1 � <br /> INFILTRATION <br /> # Scope Method SLA CFM 50 ELA EqLA ACH ACH 50 <br /> 1 Wholehouse Proposed ACH(50) .000295 1756.9 96.45 181.39 .2216 5 <br /> 1/3/2017 9�49 AM EnergyGauge�USA-FlaRes2014 Section R405.4 1 Compliant Software Page 3 of 4 <br />� <br />