Laserfiche WebLink
! - <br /> s Y ♦ <br /> Manual S Compliance Report Job: 1871 sf ADS <br /> Date: 12/29/2016 <br /> En tire Ho us e By: Dave <br /> BAYONET PLUMBING COOLING HEATING <br /> ' • - e s <br /> For: Lennar Homes <br /> o • e • e <br /> Design Conditions <br /> Outdoor design DB 91.3°F Sensible gain: 26354 Btuh Entering coil DB 75.6°F <br /> Outdoor design WB. 77.3°F Latent gain: 4092 Btuh Entering coil WB: 62.8°F <br /> Indoor design DB. 75.0°F Total gain: 30446 Btuh <br /> Indoor RH� 50% Estimated airflow� 1200 cfm <br /> Manufacturer's Performance Data atActual Design Conditions <br /> Equipmenttype: SpIitASHP <br /> Manufacturer� Lennox Model: 14HPX-036-230-18+CBX27UH-036-230*++TDR <br /> Actual airtlow� 1200 cfm , <br /> Sensible capacity' 29580 Btuh 112% of load <br /> Latent capacity� 5220 Btuh 128% of load <br /> Total capacity� 34800 Btuh 114% of load SHR. 85% <br /> � o • <br /> Design Conditions <br /> Outdoor design DB 30.8°F Heat loss: 28805 Btuh Entering coil DB. 69.7°F <br /> Indoor design DB• 70.0°F <br /> Manufacturer's Performance Data at Actual Design Conditions <br /> Equipment type: Split ASHP <br /> Manufacturer: Lennox Model: 14HPX-036-230-18+CBX27UH-036-230"++TDR <br /> Actual airtlow: 1200 cfm <br /> Output capacity: 32800 Btuh 114% of load Capacity balance: 35 °F <br /> Supplemental heat required: 0 Btuh Economic balance: -99 °F <br /> Backup equipment type: Elec strip <br /> Manufacturer� n/a Model: n/a+n/a , <br /> Actual airflow: 1200 cfm <br /> Output capacity: 0 kW 0% of load Temp. rise: 0 �F <br /> The above equipment was selected in accordance with ACCA Manual S. <br /> �- wri htsoft�' � 2016-Dec-29 09:37:U3 <br /> � � 9 Right-Suftei9 Universal 2013 13.0.09 RSU05714 <br /> Page 1 <br /> �' '� H:ILENNAR LOADS\1871 sf ADS drawn 3ton.rup Calc=MJ8 Front Door faces:SW <br />