My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
17-18232
Zephyrhills
>
Building Department
>
Permits
>
2017
>
17-18232
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/12/2017 2:05:01 PM
Creation date
12/12/2017 2:04:59 PM
Metadata
Fields
Template:
Building Department
Company Name
SIVLERADO
Building Department - Doc Type
Permit
Permit #
17-18232
Building Department - Name
LENNAR HOMES LLC
Address
36124 STABLE WILK AVE
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
26
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Manual S Compliance Report Job: 1941 sfADS <br /> Date: 12I30/2016 <br /> Entire House By: Dave <br /> BAYONET PLUMBING COOLING HEATING <br /> ' a - • � <br /> For: Lennar Homes <br /> . • • • • <br /> Design Conditions <br /> Outdoor design DB. 91.3°F Sensible gain: 26473 Btuh Entering coil DB: 75.6°F <br /> Outdoor design WB� 77.3°F Latent gain: 4393 Btuh Entering coil WB. 62.8°F <br /> Indoor design DB: 75.0°F Total gain: 30867 Btuh <br /> Indoor RH 50% Estimated airflow� 1200 cfm <br /> Manufacturer's Performance Data atActual Design Conditions <br /> Equipment type: SpIitASHP <br /> Manufacturer� Lennox Model: 14HPX-036-230-18+CBX27UH-036-230''++TDR <br /> Actual airflow: 1200 cfm <br /> Sensible capacity: 29580 Btuh 112% of load <br /> Latent capacity: 5220 Btuh 119% of load <br /> Total capacity� 34800 Btuh 113% of load SHR. 85% <br /> • • • <br /> Design Conditions <br /> Outdoor design DB. 30.8°F Heat loss: 28865 Btuh Entering coil DB� 69.7°F <br /> Indoor design DB 70.0°F <br /> Manufacturer's Performance Data atActual Design Conditions <br /> Equipment type: SpIitASHP <br /> Manufacturer: Lennox Model: 14HPX-036-230-18+CBX27UH-036-230'++TDR <br /> Actual airflow� 1200 cfm <br /> Output capacity: 32800 Btuh 114% of load Capacity balance: 35 °F <br /> Supplemental heat required: 0 Btuh Economic balance: -99 °F <br /> Backup equipment type: Elec strip <br /> Manufacturer n/a Model: n/a+n/a <br /> Actual airflow� 1200 cfm <br /> Output capacity� 0 kW 0% of load Temp. rise: 0 °F <br /> The above equipment was selected in accordance with ACCA Manual S. <br /> �, wri htsoftA 2016-Dec-3010:43:05 <br /> � 9 Right-Suite�Universal 2013 13.0.09 RSU05714 Page 1 <br /> �'�` H:\LENNAR LOADS\1941 sf ADS 3ton.rup Calc=MJ8 Front Door faces: N <br />
The URL can be used to link to this page
Your browser does not support the video tag.