Laserfiche WebLink
1 <br /> Single Family Dwelling <br /> Plan Review Comments <br /> 1. F.F.E. shall be a minimurn of 8" abave the road elevation and an engineered site plan. <br /> 2. Lots sha11 be graded to camply with R401.3 of the F.B.C. <br /> 3. Compaction test required if 24" or rnore of fill dirt is brought in at any one place. <br /> 4. Tie in survey required before pouring cancrete. <br /> 5. Driveways require a R.O.W. use permit. A114 sides of driveway thru the sidewalk shall have <br /> expansian material. <br /> 6. All setbacks shall be met. <br /> 7. Ali praperty markers shall be uncovered and marked at time af first inspection. <br /> 8. All A.D.A. requirernents shall be met. <br /> 9. No electric,plumbing, mechanical, ar framing sha11 be covered without an inspection and <br /> appraval first. <br /> 2 Q. AII Garages shall camply uri�h section R342.6 of the F.B.C. (Fire Separation}. <br /> 11. Appliances shall not be installed in a location where subject to mechanical damage unless <br /> pratected by approved barriers. M303.4 of the F.B.0 <br /> 12. Water heaters shall comply with section F607.3 of the F.B.C. <br /> 13. FQundation supports for AIC units shall be raised at teast 3"above finished grade. M1308.1 <br /> 14. Return air in all bedroorris. F.B.C. M1620.4 <br /> 15. Smoke detectars are ta be installed in accordance with R313.1 ofthe F.B.�. <br /> 16. All glazing requirements are to be in accardance with R308.4 afthe F.B.C. <br /> 17. Ali means of egress are to be in accardance with R311 of the F.B.C. <br /> 18. "Green gypsum board" shall not be used as a backer in showers or tubs. R'702.4.2 F.B.C. <br /> 19. Cambination-type AFCI breakers are required at all lacatians requiring an AFCI type breaker. <br /> 20. Carbon monoxide alarms will be required in new construction that uses fossil-burning heating <br /> ar appliances or an attached garage. They shall be installed in accordance with the F.B.C. <br /> 21. All plurnbing,mechanical, and electrical shall be separate from unit to unit. This includes all <br /> under�raund plumbing and electric. <br /> 22. A112008 N.E.C. Codes will be enfarced. <br /> 23. Tamper-Resistant Receptacles in accordance with 4Q6.11 of�he 2008 N.E.0 <br /> 22. In accordance with the Land Development Cade, lots shall be sodded before final at least 10 <br /> feet around the structure. <br /> ' F.F.E.-Finished F2aor Elevatipn <br /> � F.B.C- Florida Building Code 5�'Edition <br /> R.O.W.-Right of Way <br /> '� A.D.A.-Americans with Disabilities Act N.E.C.-National Electric Code(2008) <br /> �i <br />