Laserfiche WebLink
a <br /> THOMAS Structural Calculations • <br /> Sign&Awning Company,Inc. Client: Optical Outlet <br /> 4590 118th Avenue North Project Identity No.: 75807 <br /> Clearwater, Florida 33762 Design No.: 60144 • <br /> Florida Certificate ofAuthorization No.31751 Prepared by:John F. Dougherty <br /> Florida P.E. License No 80640 <br /> 0.2500 IN DIA DFS'T-ANCHOR'OR 3/8" DIA <br /> MALE TYPE DFS'LIBERTY ANCHOR' <br /> OR <br /> 0.250 INCH DIATHREADED ROD EMBEDDED <br /> 2 INCHES INTO DRILLED HOLE FILLED WITH <br /> HILTI HIT-HY 10 ADHESIVE IN MESH SCREEN <br /> TUBE <br /> HOLLOW CORE CONCRETE BLOCK <br /> OR <br /> 0.250 INCH DIA. HILTI HLC SLEEVE ANCHOR <br /> EMBEDDED 1.00 INCHES INTO SHELL OF <br /> HOLLOW CELL CMU <br /> OR <br /> RED HEAD BRAND TAPCON ANCHORS:0.19 <br /> IN DIA X 1 IN EMBEDMENT <br /> HILTI HLC OR SIMPSON STRONG-TIE SLEEVE- <br /> ALL SLEEVE ANCHOR,0.3750 IN X 1.5000 IN <br /> EMBEDMENT <br /> OR <br /> GROUT-FILLED CONCRETE BLOCK <br /> 0.375 IN THREADED ROD EMBEDDED 3.375 <br /> IN INTO DRILLED HOLE FILLED WITH HILTI <br /> HIT-HY 10 ADHESIVE <br /> 4 of 5 3/8/17 <br />