My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
17-18274
Zephyrhills
>
Building Department
>
Permits
>
2017
>
17-18274
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/27/2017 7:42:26 AM
Creation date
12/18/2017 1:43:19 PM
Metadata
Fields
Template:
Building Department
Company Name
WALNUT GROVE TOWNHOMES
Building Department - Doc Type
Permit
Permit #
17-18274
Building Department - Name
WALNUT GROVE TOWNHOMES
Address
37732 PRAIRIE ROSE LP LOT 10
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
83
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
� � -- . ��� <br /> . : � <br /> FORM R405-2014 <br /> FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION <br /> Florida Departmei t of Business and Professional Regulation - Residential Performance Method <br /> Project Name: R0217051�Unit 8-1 and S-6 Builder Name: Buttertield <br /> Street: 4408 Court St Permit Office: City of Zephyrhills <br /> City,State,Zip: Zephyrhills,FL,33542 Permit Number: 1 �Z� I-'�j Z,7 l <br /> Owner: Typical-End Units 8-1 and S-6 Jurisdiction: 611600 <br /> Design Location: FL,Tamp i County:: Pasco(Florida Climate Zone 2) <br /> 1 New construction or existing , New(From Plans) 9. Wall Types(1085.3 sqft.) Insulation Area <br /> 2. Single family or multiple family � Single-family a.Concrete Block-Ext Insul,EMerior R=5.0 898.67 ft' <br /> � b.Frame-Wood,Adjacent R=13.0 186.67 ft2 <br /> 3. Number of units,if multiple family 1 c.N/A z <br /> R= ft <br /> 4. Number of Bedrooms 3 d.N/A R= ftz <br /> 5. Is this a worst case? No 10.Ceiling Types (1435.0 sqft.) Insulation Area <br /> , a.Under Attic(Vented) R=30.0 1435.00 ft2 <br /> 6. Conditioned floor area above Igrade(ft� 1435 b.N/A R= ftz I <br /> Conditioned floor area below grade(ftZ) ; 0 c.N/A R= ft2 , <br /> 11.Ducts R ftZ <br /> 7. Windows(137.0 sqft.) Description Area a.Sup:Attic,Ret:Attic,AH:ah 6 175 <br /> a. U-Factor: DbI,lU=0.30 � 137.00 ft' <br /> SHGC• SHGC=025 <br /> b. U-Factor: N/A ft= 12.Cooling systems kBtu/hr Efficiency <br /> SHGC: , a.Central Unit 27.8 SEER:14.00 <br /> c. U-Factor: N/A ftZ <br /> SRGC: ' � 13.Heating systems kBtu/hr Efficiency <br /> d. U-Factor N/A , ft' a.Electric Strip Heat 27.3 COP:1.00 <br /> SHGC: <br /> Area Weighted Average Overhang Depth: 1.672 ft. <br /> Area Weighted Average SHGC: 0.250 14 Hot water systems <br /> 8. Floor Types (1435.0 sqft.) Insulation Area a.Electric Cap:40 gallons <br /> EF.0.970 <br /> a.Slab-On-Grade Edge Insulation ;R=0.0 1435.00 ft2 b. Conservation features <br /> b.N/A ;R= ft2 None <br /> c.N/A R= �Z 15.Credits CF,Pstat <br /> Glass/Floor Area: 0.095 <br /> Total Proposed Modified Loads: 45.03 pASS <br /> � Total Baseline Loads: 46.69 <br /> I hereby certify that the plans and specifications covered by Review of the plans and , ���x.g�, ' <br /> this calculation are in compliance with the Florida Energy specifications covered by this �Q�. ����'�c�r, <br /> Code. ' � calculation indicates compliance ����,, � ��-r�:',� +a <br /> r.Y``.�»� <br /> ��i'(�,,,�, with the Florida Energy Code. 1�" !r�„��t;:�=:� ;r�„�C3. <br /> .�Ze� .,� .. .� <br /> PREPARED BY: � Before construction is completed -� <br /> DATE: 02-10-17 this building will be inspected for � �"�`i;�r� ,� <br /> � compliance with Section 553.908 `* . � °� �; <br /> I hereby certify that this building,as designed, is in compliance Florida Statutes. ,,� . �� <br /> with the Florida Energy Code. ��-yy�,�► <br /> OWNER/AGENT: � BUILDING OFFICIAL: <br /> -DATE: - - -- - - - - � - - � - - - - - - DATE: �- O�� - - - - - - <br /> i <br /> - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as <br /> certified factory-sealed in accordance with R403.2.2.1. <br /> -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and an envelope leakage <br /> test report in accordance with R402.4.1.2. i <br /> 2/10/2017 12:33 PM EnergyGauge�USA-FlaRes2014 Section R405.4 1 Compliant Software Page 1 of 5 ,l <br /> �` <br /> , , �• <br /> � ! <br />
The URL can be used to link to this page
Your browser does not support the video tag.