Laserfiche WebLink
�°'� <br /> WEATHER KING PORTABLE BUILDINGS <br /> 760 WESTBROOK ROAD <br /> HICKORY, KY 42051 <br /> GENERAL NOTES: DESIGN CRITERIA: ITEMS BY OTHERS: <br /> 1.STRUCTURE HAS BEEN DESIGNED IN ACCORDANCE WITH 10.WOOD FRAMING SHALL COMPLY WITH THE NATIONAL 1.DESIGN LOADS ARE IN ACCORDANCE WITH THE FOLLOWING ITEMS MAY BE SUPPLIED AND <br /> THE 2014 FLORIDA BUILDING CODE(FBC). FOREST PRODUCTS ASSOCIATION(NFPA)"NATIONAL THE FLORIDA BUILDING CODE,2014. INSTALLED BY OTHERS.THESE ITEMS MAY BE <br /> DESIGN SPECIFICATION FOR WOOD CONSTRUCTION",2012. OCCUPANCY CATEGORY I SUBJECT TO LOCAL JURISDICTION APPROVAL. <br /> 2.ALL MATERIALS AND CONSTRUCTION SHALL BE IN WEATHER KING PORTABLE BUILDINGS IS NOT <br /> ACCORDANCE WITH THE ABOVE CODES AT THE TIME OF 11.ALL ROOF DECKING IS TO BE J�6"O.S.B. 2.LIVE LOADS: RESPONSIBLE FOR THESE ITEMS. <br /> MANUFACTURE. FLOOR:40 PSF <br /> 12.ALL SIDING IS TO BE TREATED Tt-11,LP SMARTSIDE LOFT:10 PSF 1.THE FOUNDATION TIE-DOWN SYSTEM <br /> 3:DRAWINGS SHALL NOT BE SCALED FOR DIMENSIONS. PANEL,OR 29 GA.MEI'AL SIDING. ROOF:20 PSF <br /> 2.RAMPS,STAIRS,AND GENERAL ACCESS <br /> 4.STRUCTURES ARE CLASSIFIED AS"MINOR STORAGE 13.ALL FLOOR JOISTS ARE TO BE PRESSURE TREATED 3.WIND LOADS ARE BASED ON THE FOLLOWING: <br /> FACILITIES"(OCCUPANCY CATEGORY I)AND SHOULD NOT BE SYP#2,OR BETTER. " ULTIMATE DESIGN WIND SPEED: 3.ELECTRICAL SERVICE HOOKUP <br /> USED FOR HUMAN HABITATION. (2014 FBC FIGURE 1609C) <br /> 14.ALL WOOD FRAMING IS TO BE TO BE SPF#2 OR BETTER, Vult=160 MPH <br /> 5.STRUCTURES ARE DESIGNED FOR LOCATIONS THAT HAVE A UNLESS NOTED OTHERWISE. RISK CATEGORY I <br /> 3 SECOND WIND GUST OF 160 MPH FOR RISK CATEGORY I EXPOSURE CATEGORY C <br /> STRUCTURES PER FIGURE 1609C OF THE 2014 FBC. 15.ALL FLOOR DECKING IS TO BE 5/"TREATED PLYWOOD. INTERNAL PRESSURE COEFFICIENT: <br /> UN-TREATED T8G PLYWOOD FLOORING MAY BE USED GCpi=t0.18 <br /> 6.SIDING FASTENERS SHALL NOT BE INSTALLED IN PANEL SIDING WHERE THE BOTTOM OF THE FLOORING IS OVER 18"ABOVE COMPONENTS&CLADDING: <br /> GROOVES IN THE FIELD OF THE PANEL OR WHEN THE SIDING THE GROUND. LOADS SHOWN HAVE NOT BEEN ADJUSTED FOR <br /> , GROOVES OCCUR AT CUT EDGES OF THE SIDING PANEL. LOAD COMBINATIONS IN FBC SECTION 1605. <br /> 16.ALL SKIDS ARE TO BE 4x6 PRESSURE TREATED, <br /> 7.STRUCTURES ARE DESIGNED FOR LOCATIONS THAT ARE NOT RATED FOR GROUND CONTACT. EFFECTIVE WIND AREA,Ae=10 FT1 <br /> IN FLOOD HAZARD AREAS. STRUCTURES SHOULD NOT BE ROOF-ZONE 1=32.2,-51.1 PSF <br /> USED IN OTHER LOCATIONS. 17.NAIL IN ACCORDANCE WITH RECOMMENDED WOOD ROOF-ZONE 2=32.2,-88.9 PSF��r�D� <br /> FASTENING SCHEDULE PER TABLE 2304.9.1 OF THE ROOF-ZONE 3=32.2,-131.5 PS��0 m� <br /> 8.IN ACCORDANCE WITH FBC 1609.1.2,STORAGE SHEDS NOT 2014 FBC. WALL-ZONE 4=55.8,�0.5 PSFO O�G <br /> DESIGNE�FOR HUMAN HABITATION WITH A FLOOR AREA WALL-ZONE 5=55.8,-74.7 PSF,�Z�D� <br /> OF 720 SQUARE FEET OR LESS ARE NOT RE�UIRED TO COMPLY 18.ALL EXTERIOR NAILS ARE TO BE ZINC COATED. ��r <br /> WITH THE MANDATORY WINDBORNE DEBRIS IMPACT STANDARDS 4.CONSTRUCTION TYPE:V-B �r�Z�' <br /> OF THE 2014 FBC. 19.STRUCTURES SHOULD HAVE 30 YEAR RATED FIBERGLASS/ �� '��C�� <br /> ASPHALT SHINGLES OR 29 GA METAL ROOF PANELS. <br /> 9. IN ACCORDANCE WITH FBC 1008.1.1,BUILDINGS THAT ARE 400 � � '�n v 0� <br /> S�UARE FEET OR LESS THAT ARE INTENDED FOR USE IN 20.ALL BUILDINGS ARE TO BE ADEQUATELY ANCHORED TO � �� , i�y z�� <br /> CONJUNCTION WITH ONE-AND TWO-FAMILY RESIDENCES TO RESIST WIND LOADS. REFER TO THE MASTER ppp��� P� <br /> ARE NOT SUBJECT TO THE DOOR HEIGHT AND WIDTH ANCHORING PLANS,SUBMITTED SEPARATELY,FOR � O `•o �(7�(A� <br /> REQUIREMENTS OF THE 2014 FBC. REQUIRED ANCHORING INFORMATION. �O c� (A(7 0 <br /> � <br /> ��� �mm � <br /> -°'''°"""u"N°""�--.. LOFTED BARN--FLORIDA- D=160 PH�-FBC 2014 � <br /> ����,L ��� � <br /> :�.�GENS�•,� '� <br /> -... <br /> �*;� N0.77209 •;*% PROJECT N0: <br /> _ ; * _ . SHEET NUMBER <br /> ��:.. �'P� DATE: 06-05-2015 <br /> � ..��F� : `� DRAwN ev KLN S-O-LB-FL <br /> '� <� P•• ��`,` ������ ��� � CHECKEDBY• KLN <br /> � • !�g�«� ■ p�r ■ sy�r�y <br /> ` ','�����Omnn���oA`���� �a�R#���s� P�/'��cifl�ii�� REVISION: SCALE:NONE <br />