Laserfiche WebLink
. . <br /> FORM R405-2014 <br /> F'LORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION <br /> Florida Department of Business and Professional Regulation - Residential PerFormance Method <br /> Project Name: 2600 sf ADS Builder Name: LENNAR HOMES <br /> street: 6587 Paden Wheel Street Permit Office: Cl of Zephyrhills <br /> City,State,Zip: ,FL, Permit Number� ��6 6 <br /> Owner� LENNAR HOMES Jurisdiction: 611600 <br /> Design Location: FL,Tampa <br /> 1. New construction or existing New(From Plans) 9. Wall Types(2400.6 sqft.) Insulation Area <br /> 2. Single family or multiple family Single-family a.Concrete Block-Int Insul,Exterior R=4.1 2031.60 ftz <br /> b.Frame-Wood,Adjacent R=11.0 369.00 ft2 <br /> 3. Number of units,if multiple family 1 c.N/A : <br /> R= ft <br /> 4. Number of Bedrooms 4 d.N/A R= ftZ <br /> 5. Is this a worst case? Yes 10.Ceiling Types (2600.0 sqft.) Insulation Area <br /> a.UnderAttic(Vented) R=30.0 2193.00 ftZ <br /> 6. Conditioned floor area above grade(ftz) 2599 b.CathedraUSingle Assembly(Vented) R=30.0 407.00 ftZ <br /> Conditioned floor area below grade(ft2) 0 c.N/A R= ftZ <br /> 11 Ducts R ftz <br /> 7. Windows(300.2 sqft.) Description Area a.Sup:Attic,Ret:Main,AH:Main 6 645 <br /> a. U-Factor• Dbl,U=0.54 141.68 ft2 <br /> SHGC• SHGC=0.31 - <br /> b. U-Factor Dbl,U=0.58 72.00 ftz 12.Cooling systems kBtu/hr Efficiency <br /> SHGC� SHGC=0.32 a.Central Unit 43.5 SEER:15.50 <br /> c. U-Factor• Dbl,U=0.56 48.00 ftZ <br /> SHGC� SHGC=0.32 13.Heating systems kBtu/hr Efficiency <br /> d. U-Factor� other(see details) 38.50 ft2 a.Electric Heat Pump 43.5 HSPF:9.00 <br /> SHGC� other(see details) <br /> Area Weighted Average Overhang Depth: 5.520 ft. <br /> Area We'ighted Average SHGC• 0.310 14 Hot water systems <br /> 8. Floor Types (2599.0 sqft.) Insulation Area a.Electric Cap:40 gallons <br /> EF 0.950 <br /> a.Slab-On-Grade Edge Insulation R=0.0 2599.00 ft� b. Conservation features <br /> b.N/A R= ftZ None <br /> c.N/A R= ftZ 15.Credits Pstat <br /> Glass/Floor Area: 0.115 Total Proposed Modified Loads: 75.53 pASS <br /> _ Total Baseline Loads. 78.49 <br /> I hereby certify that the plans and specifications covered by Review of the plans and ��'S��.ST:q�. , <br /> this calculation are in compliance with the Florida Energy specifications covered by this �. '" =:,,�Q+,�, . <br /> Code. calculation indicates compliance �'�iiif��'�� I.�'r`��.��`� <br /> `/��/�r/n �/ /n with the Florida Energy Code. � ?r,ru.�'�r.;;,;::�•�'�+=`„ O <br /> U/VL✓G f{�f!G/1. ^ �y.risi"�� <br /> PREPARED BY: Before construction is completed 'c� �' �� � <br /> DATE. this building will be inspected for � • I`�7�`M :,� <br /> compliance with Section 553.908 * � ° � ,� <br /> I hereb certi that this buildin as desi ned,is in com liance Florida Statutes. .+ „ <br /> Y fY 9, 9 P �"�, ��s� . <br /> with the Florida Energy Code. �L?y�i�,'� <br /> OWNER/AGENT. BUILDING OFF AL. <br /> DATE: / � DATE. � <br /> - Compliance requires certification by the air handler unit manufacturer that the air handler enclo ure qualifies as <br /> certified factory-sealed in accordance with R403.2.2.1. <br /> -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and an envelope leakage <br /> test report in accordance with R402.4.1.2. <br /> - Compliance with a proposed duct leakage Qn requires a Duct Leakage Test Report confirming duct leakage to outdoors, <br /> tested in accordance with Section 803 of RESNET Standards,is not greater than 0.030 Qn for whole house. <br /> 1/3/2017 9:20 AM EnergyGauge�USA-FlaRes2014 Section R405.4 1 Compliant Software Page 1 of 4 <br />